You are on page 1of 7

1.

Known as the Water Code of the Philippines


A. RA 1080
B. PD 1067
C. RA 1037
D. PD 856
2. The Revised ational Pl!"#in$ Code of the Philippines of 1%%% was approved on
A. &!ne 18' 1%55
B. &an!ar( )8' 1%5%
C. ove"#er )8' 1%67
D. De*e"#er )1' 1%%%
3. +,piration of pl!"#in$ per"it if s!spended or a#andoned for a period
of
A. 60 da(s
B. 365 da(s
C. 1)0 da(s
D. 180 da(s
4. A-PAP was or$ani.ed and re$istered to /+C
A. 1%50
B. 1%%%
C. 1%35
D. 1%50
5. Known as the Code on /anitation of the Philippines
A. PD %07
B. PD 865
C. PD 856
D. PD 586
6. The two *a!ses of fi,t!re trap seal loss that vent s(ste"s prote*t a$ainst in nor"al
fi,t!re !se are
A. #a*1flow and #a*12press!re
B. siphona$e and #a*12press!re
C. va*!!" and #a*1flow
D. va*!!" #rea1er and #a*1flow preventer
7. Another ter" !sed to des*ri#ed a *ontin!o!s vent is
A. vent pipe
B. vent sta*1
C. sta*1 vent
D. soil sta*1
8. The trade na"e for relief vent is
A. d!al vent
B. re2vent
C. #a*1 vent
D. *i*!it vent
9. A vent *onne*tin$ to a hori.ontal drain pipe thro!$h a fittin$ at an an$le not $reater the
05 de$rees to the verti*al is
A. side vent
B. #a*1 vent
C. *o""on vent
D. (o1e vent
10. The dr( portion of a soil or waste pipe that e,tends a#ove the hi$hest hori.ontal drain
*onne*ted to the sta*1 and ter"inates a#ove the roof is
A. vent sta*1
B. (o1e vent
C. sta*1 vent
D. d!al vent
11. The f!n*tion is to *onne*t two or "ore vent pipes to the "ain vent at one point' or
e,tend thro!$h the roof separatel( is
A. vent e,posed
B. vent line
C. vent header
D. vent *ap
12. The p!rpose is to prevent the press!re *han$es in the sta*1
A. relief vent
B. (o1e vent
C. re2vent
D. loop vent
13. A positive press!re is
A. siphona$e
B. #a*1 press!re
C. va*!!"
D. #a*1flow
14. The ne$ative press!re is *alled
A. trap seal loss
B. siphona$e
C. #a*1 press!re
D. #a*1flow
15. What will happen if the "a,i"!" fi,t!re !nit load in*reases
A. the hei$ht of the vent pipe in*reases
B. the hei$ht of the vent pipe de*reases
C. the hei$ht of the vent pipe "aintains
D. the hei$ht of the vent pipe do!#les
16. -ini"!" vent si.e for water *loset is
A. 1 in*h3
B. ) in*hes3
C. ) 14)5 in*hes3
D. 3 in*hes3
17. The s"allest individ!al vent sta*1 si.e per"itted #( the *ode is
A. 1 1405
B. 1 14)5
C. 15
D. )5
18. The "a,i"!" vent si.e that *an #e !sed for a 3 in*hes drain pipe is
A. 1 14)5
B. )5
C. ) 14)5
D. 1 1405
19. The fa*tor that deter"ines the "a,i"!" len$th of an( vent pipe is
A. invert
B. dia"eter
C. fi,t!re load
D. *olor
20. Kit*hen sin1s lo*ated awa( fro" walls or partitions are *alled
A. slop sin1
B. *enter sin1
C. island sin1
D. isolated sin1
21. -a,i"!" len$th of hori.ontal wet vent is
A. 0350 foot
B. 1 foot
C. 1 14) feet
D. ) feet
22. Also 1nown as the RA %)75
A. Water Code of the Philippines
B. ational 6!ildin$ Code of the Philippines
C. Philippine Clean Water A*t of )000
D. Code on /anitation of the Philippines
23. The first a"end"ent of the ational Pl!"#in$ Code whi*h in*l!des As#estos2Ce"ent
pipe as approved pl!"#in$ "aterials was
A. &!ne 18' 1%55
B. De*e"#er )1' 1%%%
C. ove"#er )8' 1%67
D. &an!ar( )8' 1%5%
24. 7ow "an( provision of the -aster Pl!"#er Code of +thi*s
A. 6
B. 7
C. 8
D. %
25. 7ow "an( set of plans ret!rn to the appli*ant after approval of per"it
A. 6
B. 1
C. )
D. 0
26. 7ow "an( set of plans retain to the 8o#site after approval of per"it
A. 1
B. )
C. 3
D. 0
27. 7ow "an( set of plans retain to the Ad"inistrative A!thorit( after approval of per"it
A. 1
B. )
C. 3
D. 0
28. ational Pl!"#in$ Code of the Philippines approved #( the -ala*a9an$
A. &!ne 18' 1%55
B. &an!ar( )8' 1%5%
C. ove"#er )8' 1%67
D. De*e"#er )1' 1%%%
29. -ini"!" vol!"e of the di$estive *ha"#er of a septi* tan1
A. 1 *!3"
B. ) *!3"
C. 135 *!3"
D. )35 *!3"
30. The "ini"!" differen*e in elevation of the inlet and o!tlet pipe of the septi* tan1
A. 5038 ""
B. 10)38 ""
C. 15)38 ""
D. )0038 ""
31. /tandard *onversion fa*tor to "!ltipl( the TD7 in feet to a*:!ire the press!re in psi of
water in a pipe to a *ertain elevation
A. 6)30
B. 03033
C. 3)3)
D. %381
32. 1 *!#i* "eters of water is e:!al to
A. )50 $allons
B. 1500 liters
C. 1000 1$s
D. )500 l#s3
33. 1 *!#i* "eters of water is e:!al to
A. 10 liters
B. 100 liters
C. 1000 liters
D. 10'000 liters
34. 1 *!#i* "eters is how "an( $allons
A. 105 $allons
B. )60 $allons
C. )85 $allons
D. 365 $allons
35. 1 psi is e:!al to
A. 638%5 1pa
B. %3876 1pa
C. 33678 1pa
D. 73365 1pa
36. Known as the /anitar( +n$ineerin$ ;aw
A. RA %)75
B. RA 1378
C. RA 1360
D. RA %510
37. Known as the <ire Code of the Philippines of )008
A. RA %)75
B. RA %510
C. RA 1368
D. RA %)50
38. The re:!ire"ent of the Dr( /tandpipe in ever( 0 store( or "ore was stated in
A. PD %07
B. PD 10%3
C. PD )5%6
D. PD 10)5
39. A pipeline s(ste" filled with water and *onne*ted to a *onstant water s!ppl( for the
!sed of the 6<P for <ire /!ppression p!rposes is
A. Dr( /tandpipe
B. Wet /tandpipe
C. Co"#ination /tandpipe
D. /tandard /tandpipe
40. The "ini"!" si.e of Dr( /tandpipe is
A. 60"" =) 14)5>
B. 5)"" =)5>
C. 38"" =1 14)5>
D. 10)"" =05>
41. ?s a te*hni:!e where#( air is #lown into spa*es whi*h are desi$ned to #e 1ept *lear
s"o1e
A. Aeration
B. Paste!ri.ation
C. Press!ri.ation
D. Co"pressed Air
42. The pipes are nor"all( not filled with water3 Water is introd!*ed into the s(ste" thr!
fire servi*e *onne*tion is
A. Dr( /tandpipe
B. Wet /tandpipe
C. Co"#ination /tandpipe
D. /tandard /tandpipe
43. The "a,i"!" travel distan*e of a Dr( /tandpipe o!tlet *onne*tion to an( point in a
#!ildin$ is
A. )0 "eters
B. 30 "eters
C. 00 "eters
D. 50 "eters
44. ?s an a!,iliar( fireline s(ste" with *onstant water s!ppl( installed pri"aril( for
e"er$en*( !se
A. Dr( /tandpipr
B. Wet /tandpipe
C. Co"#ination /tandpipe
D. /tandard /tandpipe
45. The "a,i"!" hei$ht of a <ire /ervi*e Conne*tion a#ove $radeline is
A. 060""
B. 1)00""
C. 1))0""
D. )110""
46. The valve dia"eter "!st #e installed in ever( floor for a Wet /tandpipe is
A. 3)"" =15>
B. 38"" =1 1405>
C. 5)"" =)5>
D. 60"" =) 14)5>
47. /tandard slope of all hori.ontal r!ns of a Dr( /tandpipe is
A. 5@
B. 10@
C. 15@
D. )0@
48. -ini"!" hei$ht of a Wet /tandpipe a#ove floor is
A. 810""
B. %10""
C. 1100""
D. )100""
49. The "ini"!" press!re of the h(drostati* testin$ for the Dr( /tandpipe is
A. 50psi =3351$4*")>
B. 60psi =0351$4*")>
C. 70psi =5301$4*")>
D. 80psi =6351$4*")>
50. What is the "a,i"!" Dr( /tandpipe desi$n press!re to withstand water press!re when
read( for servi*eA
A. 100psi
B. )00psi
C. 300psi
D. 000psi