You are on page 1of 21

Daily Site Report

Site
: HAYDARIA
Report No. : 26
Date
: Sun 12/02/2012

Man power

Sub Contractor

Admin.
2

Engineer
7

Surveyor
1

Admin.

Engineer

Surveyor

FBC
MO

Eng.
in

power

charge

Min:6

Pr

en
t

Job Description & Comment

Man

Eq
ui
pm

Section

No.

Weather: sunny Max:17

Civil works
Mobilization
1
2
3
4
5

Eng.Wissam
supplying sub base for storage area
Eng.Ali Omran
spreading and leveling sub base for storage area .
surveyor Karar
wetting & compacting for storage area .
continue civil work for building toilets foundations and in camp area ( curing for foundations ) .
continue caravans installation , install structure basement on camp foundation

grader
water tank

95
70
60
95
10

soil investigation
still waiting for receiving the comments from Dr.Saffa
about soil investigation report .

1
2
3

electrical work (11 kV feeding line )


Eng.Shawkat
receiving materials for installing 11KV feeding line to site ( remaining only from underground cable )
continue civil works for installing 11KV line ( determine and excavation work for poles basement ) on the route from
tire plant to site area .
continue procedure poles and cable test by inspector engineer from Najaf electricity distribution

95
10
30

directorate to check Then samples from 11KV line materials will be taken next Sunday for test in Baghdad.

receiving materials

admin. Hamza

documents

Visits and Meetings

Eng.Ali Hanoon

Site Manager Comment


From today we will stop supplying sub base for storage

Next day works


1
2
3

civil works
wetting and compacting sub base for storage area .
continue building works for toilets foundation ( curing and removing the wooden frame ).
continue caravans installation works in site.

1
2
4

electrical works
waiting for receiving remaining materials of 11KV feeding line from contractor( underground cable).
continue civil works for installing 11KV line from tire plant to site area by contractor.
going to AL- Najaf electricity distribution directorate to ask the general director to expedite sending test samples to Baghdad .

Foreman
0

technician
1

worker
1

Total
12

Foreman
1
1

technician
5
1

worker
4
4

Total
10
6
16

Min:6

en
t

Progress

Plan

Actual

start

finish

start

1/23/2012
1/25/2012
12/28/2011
1/28/2012
2/7/2012

2/4/2012
2/6/2012
1/20/2012
2/12/2012
3/29/2012

1/23/2012
1/25/2012
12/28/2012
2/4/2012
2/7/2012

12/9/2011

2/15/2012

12/9/2011

1/3/2012
1/26/2012

1/25/2012
2/18/2012

1/4/2012
2/4/2012

1/23/2012

1/30/2012

2/7/2012

finish

Site Manager Comments


upplying sub base for storage area because we were spreading and compacting sub base on large land enough amounts for more than 500 storage

for more than 500 storage containers to be there .

You might also like