WELCOME

Bineng Combined HEPP


Pre-Bid Meeting

February 8, 2017
About Hedcor, Inc.

We are Hedcor, Inc.

We specialize in the
generation of renewable
energy from run-of-river
hydropower systems.
About Hedcor, Inc.

We manage and operate 22 hydropower plants


and supplies the country
with 185MW of clean and renewable energy.
Total
Capacity 185MW
Plants 22 Our Plants

We manage and operate 21 hydropower plants


and supplies the country
with 170MW of clean and renewable energy.

TUDAYA 1
Sta. Cruz, Davao Del Sur

SABANGAN HYDRO
Sabangan, Mt. Province TUDAYA 2
Capacity: 14 MW Sta. Cruz, Davao Del Sur
PROJECT LOCATION

Presentation Title
5
February 8, 2017
PROJECT LOCATION

Project Presentation
6
February 8, 2017
Existing Bineng Cascading Hydropower Plants

Bineng 1 Powerhouse
3.2MW

Bineng 2 Powerhouse
1.8MW

Presentation Title
7 Bineng 2b Powerhouse February 8, 2017
0.75MW
Existing Bineng Cascading Hydropower Plants

NCGP

350 m 1000m
23kV T/L 5000m
, 336.4 ACSR

650 m
200 m 50 m 850 m

BANENGBENG MAIN SUBSTATION

BINENG 3

BINENG 1 BINENG 2 BINENG 2B


8 Existing Capacity Presentation Title
February 8, 2017
5.95 MW
Existing Transmission Line

BANENGBENG MAIN SUBSTATION

5000 m BINENG 3

850 m

BINENG 2B
1000 m
BINENG 2 50 m
350 m
200 m
BINENG 1
650 m
Presentation Title
9
February 8, 2017
BIRD EYE VIEW OF PROPOSED BN COMBINED

Project Presentation
10
February 8, 2017
Bineng Combned Hydropower Plant

5000m

STR5

1000m

30 MVA
13.8kV/69kV

New CapacityPresentation Title


11
19 MW February 8, 2017
Proposed Transmission Line (Bineng Combined)

5000 m

850 m

STR 5
1000 m BINENG COMBINED

Project Presentation
12
February 8, 2017
WEIR AND DESANDER LOCATION

Weir Data
Length 38.90 m
Width 8.30 m
Height 6.30 m

Desander Data Headrace Data


Length 86.80 m Length 145.00 m
Width 7.00 m Diameter 1.90 m
Presentation Title
Height
13 8.50 m Thickness 7.00 mm February 8, 2017
DESANDER LOCATION

Presentation Title
14
February 8, 2017
DESANDER LOCATION

Presentation Title
15
February 8, 2017
EXISTING BINENG 2B PLANT/BINENG COMBINED
POWERHOUSE LOCATION
Existing Bineng 2B Plant and Bineng Combined Powerhouse Location

Presentation Title
16
February 8, 2017
BINENG COMBINED POWERHOUSE LOCATION

Presentation Title
17
February 8, 2017
Technical Details at WEIR
BACK TO MAP

Project Presentation
18
February 8, 2017
Technical Details at POWERHOUSE
BACK TO MAP

Presentation Title
19
February 8, 2017
Bineng Combined HEPP Substation Project

BACK TO MAP

1. Scope of Works
2. Technical Drawings

Presentation Title
20
February 8, 2017
Bineng Combined HEPP Transmission Line Project

1. Geographical Location
2. Connection of Bineng 3
3. Transmission Line Profile
4. Type of Structures
5. Structure Details
6. Scope of works

Presentation Title
21
February 8, 2017
TRANSMISSION LINE ALIGNMENT

1.0kM Single
Circuit
Transmission Line

Structure with
Special Start of Double
Foundation Circuit Structure

5.0kM Double Circuit


Transmission Line

Connection Point
Substation

Presentation Title
22
February 8, 2017
CONNECTION POINT OF BINENG 3 AT STRUCTURE 5
TO TAPPING POINT (BMS)

TO BINENG
COMBINED HEPP
TOP VIEW

TO BINENG 3 HEPP

Presentation Title
23
February 8, 2017
CONNECTION POINT OF BINENG 3 AT STRUCTURE 5

BINENG 3 HEPP

SECTION A-A VIEW

Presentation Title
24
February 8, 2017
CONNECTION POINT OF BINENG 3 AT STRUCTURE 5

TO CONNECTION POINT (BMS)

TO BINENG
COMBINED HEPP
TOP VIEW

TO BINENG 3 HEPP

Presentation Title
25
February 8, 2017
CONNECTION POINT OF BINENG 3 AT STRUCTURE 5

TO BINENG COMBINED HEPP TO TAPPING POINT (BMS)

TO BINENG 3 HEPP

SECTION B-B VIEW

Presentation Title
26
February 8, 2017
TRANSMISSION LINE PROFILE

Presentation Title
27
February 8, 2017
STRUCTURE TYPE
60 FT 3T SINGLE CIRCUIT STRUCTURE

TOP VIEW
Presentation Title
TOP VIEW February 8, 2017
28 BILL OF MATERIALS
STRUCTURE TYPE
60 FT 3T SINGLE CIRCUIT STRUCTURE

LEFT SIDE VIEW BILL OF MATERIALS


29
FRONT VIEW RIGHT SIDE VIEW Presentation Title
February 8, 2017
STRUCTURE TYPE
75 FT 3T DOUBLE CIRCUIT STRUCTURE

TOP VIEW

30

BILL OF MATERIALS
STRUCTURE TYPE
75 FT 3T DOUBLE CIRCUIT STRUCTURE

LEFT
31 SIDE VIEW FRONT VIEW RIGHT SIDE VIEW BILL OF
Presentation TitleMATERIALS
February 8, 2017
75 FT 3T DOUBLE CIRCUIT STRUCTURE
SPECIAL FOUNDATION (BOM to follow
LEGENDS

PEDESTAL REINFORCEMENT ISOMETRIC VIEW

Note: This is initial design, the client will send the


Finalized drawings and BOM for this item by email.

Presentation Title
32
February 8, 2017
ANCHOR ISOMETRIC VIEW
STRUCTURE COMPONENTS/ACCESORIES
DETAILS

DETAIL A DETAIL B

Presentation Title
33
February 8, 2017
DETAIL C DETAIL D DETAIL E
STRUCTURE COMPONENTS/ACCESORIES
DETAILS

Presentation Title
February 8, 2017
DETAIL G
DETAIL F
STRUCTURE COMPONENTS/ACCESORIES
DETAILS

DETAIL I

35 DETAIL H Presentation Title


February 8, 2017
Bineng Combined Connection Point Project

1. Scope of Work
2. Technical Drawings

Presentation Title
36
February 8, 2017
Bineng Combined Connection Point Project

Presentation Title
37
February 8, 2017
Bineng Combined Connection Point Project

SLD

To Calot TP
69kV

From Bineng Combined


69kV

From Bineng 3
23kV

To Ampohaw
69kV

Presentation Title
38
February 8, 2017
TENDERING SCHEDULE

Tendering Process Timeline


Pre-Bid Conference and Site Inspection February 8,2017
Submission of Bid April 7 2017
Contract Awarding April 17, 2017
CONTACT PERSONS

If you have some clarifications, you may contact us at the following address:

Engr. Primo P Banisa


Engr. James U. Balangyao Jr.
Engr. Martin J. Anacio

Mobile. Number: +63920 908 8860 (Mr. Banisa)


+63909 943 5927 (Mr. Balangyao)
+63948 446 8227 (Mr. Anacio)

Email add: primo.banisa@aboitiz.com


james.balangyao@aboitiz.com
martin.anacio@aboitiz.com

You might also like