You are on page 1of 6

INSPECTION TEST PLAN

MATERIAL CLAUSE TEST FIELD/LAB TEST METHOD

Specific gravity of
aggregates by field/lab IS 2386
4.1.2.5 Pycnometer

Particle size fileld/lab


Aggregate 4.1.2.3

Estimation organic field/lab IS 2386-PART 2


inpuries
4.1.2.4

Surface moisture field/lab IS 2386

Determination of 10% field/lab IS 2386


fine value

Specific gravity field/lab IS 2386

bulk density field/lab IS 2386

Agg.Crushing strength field/lab IS 2386

Agg.compaction field/lab IS 2386

Standard consistency of
Cement cement by Vicats Lab
Apparatus IS 4031 Part 6
Fineness Lab IS 4031 Part 2
Soundness Lab IS 4031 Part 3
Setting time (Initial & Lab
Final) IS 4031 Part 5
Compressive strength Lab IS 4031 Part 6

F.A. Sieve Analysis


field/lab IS 2386
Silt content

Slump test
Concrete 4.2.2 field/lab IS 526
Cube strength

Reinforceme Tensile Strength


nt 10.1.1
Bend
Lab IS 1599/1608/1786
% Elongation
Chemical Properties
Unit Weight & Diameter

Admixture Solid Content Out-side Lab


Chloride Content Out-side Lab
Sulphate Content Out-side Lab
PH Out-side Lab
IS 9103
Specific Gravity Out-side Lab
Effect On Setting Time Site Lab
Effect On Strength Site Lab
Slump Retentation Site Lab

AAC Block Water Absorption Field/Lab IS 2185 Part 1


Drying Shrinkage Field/Lab IS 6441 Part 2
Moisture Content Field/Lab

Dimensions Field/Lab IS 2185 Part 4


Block Density Field/Lab IS 64 Part 1
Compressive Strength Field/Lab IS 6441 Part 5

Gypsum Compressive Strength IS 2542 Part 1-1979


Setting Time IS 2542 Part 1-1978
Field/Lab
Soundness IS 2547 Part 1
Residue on 150mm Sieve IS 2142 Part 1- 1981

Tile Transverse Strength


IS 1237
Water Absorption
Abbrasion
Wood Moisture Lab

Flush Door End Immersion


Lab IS 2202
Knife
Adhesion

Aluminium Thickness of IS 5523


Section anodic/powder coating Lab

IS 1124
Moisture
Granite/ 8.3 Lab
Marble Mhos Scale
Hardness
Specific Gravity IS 1122

Water Chemical & Physical


Properties
PH Value
Limits of Acidity
Limits of Alkality
Percentage of solids Lab IS 3025
(a) Chlorides
(b) Suspended matter
(c) Sulphates
(d) Inorganic solids
(e) Organic solids

Anti-termite IS 8944
NSPECTION TEST PLAN
MIN QTY MATERIAL RED FREQUENCY OF TEST RESPONSIBILITY WITNESS

Required incharge for all quantity Site / Quality Engineer


Client Representative

for every 45m^3 or part


45 m^3 Site / Quality Engineer
there of rcc work
Client Representative

10m^3 for every 45m^3 or part Site / Quality Engineer


there of rcc work Client Representative

10m^3 for every 45m^3 or part Site / Quality Engineer


there of rcc work Client Representative

10m^3 for every 45m^3 or part Site / Quality Engineer Client Representative
there of rcc work

10m^3 for every 45m^3 or part Site / Quality Engineer Client Representative
there of rcc work

10m^3 for every 45m^3 or part Site / Quality Engineer Client Representative
there of rcc work

10m^3 for every 45m^3 or part Site / Quality Engineer Client Representative
there of rcc work

10m^3 for every 45m^3 or part Site / Quality Engineer


there of rcc work Client Representative

Every 50 tonnes or part


thereof. Each brand of
Each Lot cement brought to site Site / Quality Engineer Client Representative
shall be tested as per
this frequency
thereof. Each brand of
Each Lot cement brought to site Site / Quality Engineer Client Representative
shall be tested as per
this frequency

every 45 ^3 Site / Quality Engineer


Client Representative

10m^3 every 15m^3 Site / Quality Engineer Client Representative

20 Tonne Every 20 tonne or part therof Site / Quality Engineer Client Representative

1 kg
1 kg
1 kg
Once in 6 month
1 kg
Site / Quality Engineer Client Representative
1 kg

Every batch

One per 10000 blocks


Once/ change in source
Site / Quality Engineer Client Representative
One per 10000 blocks

Once per source change Site / Quality Engineer

Client Representative

Once per 10000 no Site / Quality Engineer

Client Representative
Site / Quality Engineer
Every 1 m^3/ As per tender Client Representative

Every 50 shutters/ As per Site / Quality Engineer


tender
Client Representative

Once per source per section Site / Quality Engineer


Client Representative

100 m^2/ Part therof Site / Quality Engineer

50 sqm
Client Representative

Water from each


source shall be got
tested before the
commencement of
work and thereafter
once in every three
months till the Site / Quality Engineer Client Representative
completion of the work.
Water from municipal
source need be tested
only once in six
months. Number of
Tests for each source
shall be 3

Submission of MTC Site / Quality Engineer


Client Representative

You might also like