You are on page 1of 3

Project Name: ELECTRIC HOIST DESIGN Reference No: RMG18-02

Project Location: CANLBANG LAGUNA Designer: RMGarcia


Client Name: EDWARD KELLER PHILIPPINES, INC.
Address: - Date: 29-Jun-18
Subject: DESIGN CHECK OF ELECTRIC HOIST 1 AND 2
Reference: ASTM , AISC, NSCP 2015

Data:
Capacity := 3.00 TON := 30.00 kN
from NSCP Impact Load (20% of DL) := 0.60 TON := 6.00 kN

3D STAAD MODEL OF HOIST


3D RENDERED VIEW OF HOIST

DL + IMPACT LOAD APPLIED


UNITY RATIO RESULTS

RESULTS: Unity ration shown in figure above shows members


are all with less than 1.0 unity ratio. ALL MEMBERS ARE PASSING
for the maximum capacity load of 3T (30 kN).

Designer: ROWENA M. GARCIA


Prof. Civil Engineer
Registration No. 92201
PTR No. 5612013
Issued on: 9 Jan. 2018
Issued in: Quezon City
TIN No. 222-009-822

You might also like