Doc No:FM/QA/106

KCSL Attribute MSA Rev No:00


Issue Dt:02.04.2019
Number of Trials 3
Number of Operators 3 Date : 4/2/2019
Number of Parts 50

Part Name:- Body no. 2 Gauge number : N/A A: RAMESH


Characteristic : Paint Lumps Gauge name : N/A(Visual Insp.) B: SANJEET
C: VIRENDER
Specification:- Should not Exist Gage Type : N/A
CORRECT DECISIONS
S.NO A-1 A-2 A-3 B-1 B-2 B-3 C-1 C-2 C-3 Reference A B C
1 1 1 1 1 1 1 1 1 0 1 3 3 2
2 1 1 1 1 1 1 1 1 1 1 3 3 3
3 1 1 1 1 1 1 1 1 1 1 3 3 3
4 0 0 0 0 0 0 0 0 0 0 3 3 3
5 1 1 1 1 1 1 1 1 1 1 3 3 3
6 1 0 1 1 1 1 1 1 1 1 2 3 3
7 0 0 0 1 0 0 0 0 0 0 3 2 3
8 1 1 1 1 1 1 1 1 1 1 3 3 3
9 0 0 0 0 0 0 0 0 0 0 3 3 3
10 1 1 1 1 1 1 1 1 1 1 3 3 3
11 1 1 1 1 1 1 1 1 1 1 3 3 3
12 0 0 0 0 0 0 0 0 0 0 3 3 3
13 0 0 0 0 0 0 0 0 0 0 3 3 3
14 1 1 1 1 1 1 1 1 1 1 3 3 3
15 1 1 1 1 1 1 0 1 1 1 3 3 2
16 0 0 0 0 0 0 0 0 0 0 3 3 3
17 1 1 1 1 1 1 1 1 1 1 3 3 3
18 0 0 0 0 0 0 0 0 0 0 3 3 3
19 1 1 1 1 1 1 1 1 1 1 3 3 3
20 0 0 0 0 0 0 0 0 0 0 3 3 3
21 1 1 0 1 1 1 1 1 1 1 2 3 3
22 1 1 1 1 1 1 1 0 1 1 3 3 2
23 1 1 1 1 1 1 1 1 1 1 3 3 3
24 0 0 0 0 0 0 0 0 0 0 3 3 3
25 1 1 1 1 1 0 1 1 1 1 3 2 3
26 1 1 1 1 1 1 1 1 1 1 3 3 3
27 1 1 1 1 0 0 1 1 1 1 3 1 3
28 1 1 1 1 1 1 1 1 1 1 3 3 3
29 1 1 1 1 1 1 1 1 1 1 3 3 3
30 1 1 1 1 1 1 1 1 1 1 3 3 3
31 1 0 0 1 1 1 1 1 1 1 1 3 3
32 1 1 1 0 1 1 1 1 1 1 3 2 3
33 1 1 1 1 1 1 1 1 1 1 3 3 3
34 1 1 1 1 1 1 0 0 1 1 3 3 1
35 1 1 1 1 1 1 1 1 1 1 3 3 3
36 0 0 0 0 0 0 0 0 0 0 3 3 3
37 1 1 1 1 1 1 1 1 1 1 3 3 3
38 0 1 1 1 1 1 1 1 1 1 2 3 3
39 1 1 1 1 1 1 1 1 1 1 3 3 3
40 1 1 1 1 1 1 1 1 1 1 3 3 3
41 1 1 1 1 1 1 1 1 1 1 3 3 3
42 1 1 1 1 1 1 1 1 1 1 3 3 3
43 0 0 0 0 0 0 0 0 0 0 3 3 3
44 1 1 1 1 1 1 1 1 1 1 3 3 3
45 1 0 0 0 0 0 0 0 0 0 2 3 3
46 1 1 1 1 0 1 1 1 1 1 3 2 3
47 1 1 1 1 1 1 1 1 1 1 3 3 3
48 1 1 1 1 1 1 1 1 1 1 3 3 3
49 1 1 1 1 1 1 1 1 1 1 3 3 3
50 1 0 1 1 1 1 1 1 1 1 2 3 3

Reference:

OK Component = 1 NG Component = 0

A B C

No. of correct decisions


Effectiveness %= 95.33 96.00 96.67
Total opportunities for making decisions

A B C

No. of Ok decisions for NG parts


Miss Rate %= 0 0.67 1.33
Total opportunities for finding NG parts

A B C

No. of NG decisions for OK Parts


False Alarm %= 3.33 4 1.34
Total opportunities for finding OK parts

Result:Measurement system found satisfactory.

CRITERIA
Effectiveness % > 90% which is conforming to the specifications
Miss Rate % < 2% which is conforming to the specifications
False Alarm % < 5% which is conforming to the specifications

Prepared By:- Approved By:-


12 36 TOTAL NG PARTS
38 114 TOTAL OK PARTS

KEY TO MISS RATE KEY TO FALSE ALARM


A B C A B C
1 0 0 0 0 0 0
2 0 0 0 -4 0 0
3 0 0 0 -4 0 0
4 0 1 0 0 0 0
5 0 0 0 -7 0 0
6 0 0 0 0 0 0
7 0 0 0 -9 0 0
8 0 0 0 -10 0 0
9 0 0 0 0 0 0
10 0 0 0 0 0 0
11 0 0 0 -13 0 0
12 0 0 0 -14 0 1
13 0 0 0 0 0 0
14 0 0 0 -16 0 0
15 0 0 0 0 0 0
16 0 0 0 -18 0 0
17 0 0 0 0 0 0
18 0 0 0 -20 1 0
19 0 0 0 -21 0 1
20 0 0 0 -22 0 0
21 0 0 0 0 0 0
22 0 0 0 -24 0 1
23 0 0 0 -25 0 0
24 0 0 0 -26 1 1
25 0 0 0 -27 0 0
26 0 0 0 -28 0 0
27 0 0 0 -29 0 0
28 0 0 0 -29 1 0
29 0 0 0 -31 1 0
30 0 0 0 -32 0 0
31 0 0 0 -33 0 2
32 0 0 0 -34 0 0
33 0 0 0 0 0 0
34 0 0 0 -36 0 0
35 0 0 0 -36 0 0
36 0 0 0 -38 0 0
37 0 0 0 -39 0 0
38 0 0 0 -40 0 0
39 0 0 0 -41 0 0
40 0 0 0 0 0 0