You are on page 1of 2

#4机组缺陷管理台账/The Maintenance Working List of Unit4

序号 专业 缺陷内容 the maintenance item discovery time complette time 备注

1 汽机 GV2调门卡涩 GV2 is stuck 2018.08.27 2019.08.29

2 汽机 高压缸排气温度1、3显示坏点 High pressure cylinder exhaust temperature 1, 3 display bad point 2018.08.27 2019.09.02

3 汽机 循环水A/B侧二次滤网不能投入运行 Secondary filters on the A/B side of circulating water cannot be put into operation 2018.08.27 2019.08.29

4 汽机 循环水A/B侧胶球系统不能投入运行 The circulating water A/B side rubber ball system is not operational 2018.08.27 2019.08.29

5 汽机 凝器坑排污泵未工作 Condenser pit sewage pump not working 2018.08.27 2019.08.29

6 汽机 开式水电动滤水器不能投入运行 The open water electric filter is not operational 2018.08.27 2019.09.02

7 汽机 开式水手动滤水器不能投入运行 The open water manual filter is not operational 2018.08.27 2019.09.02

8 汽机 高加进水三通阀内漏 High add water three way valve leakage 2018.08.27 2019.08.29

9 汽机 A电泵不能投入运行 A the pump is not operational 2018.08.27 2019.09.02

10 汽机 A凝结水泵进口滤网差压高报警 A differential pressure alarm of inlet filter screen of condensate pump 2018.08.27 2019.08.29

11 汽机 B凝结水泵进口滤网差压高报警 B. Alarm of differential pressure of filter screen at the inlet of condensate pump 2018.08.27 2019.08.29

12 汽机 循环水泵冷却水增压泵不能投运 Circulating pump cooling water booster pump can not be put into operation 2018.08.27 2019.09.02

13 锅炉 省煤器出口水温坏点 The water temperature at the economizer outlet is bad 2018.08.27 2019.09.01

14 锅炉 D磨热风插板门经常卡涩打不开 D grinding hot air plug door often not open astringent 2018.08.27 2019.08.31

15 锅炉 D磨出口CO含量坏点 D grinding outlet CO content bad point 2018.08.27 2019.08.31

16 锅炉 D磨润滑油池温度2无法显示 D grinding oil pool temperature 2 cannot be displayed 2018.08.27 2019.08.31

17 锅炉 E磨冷风插板门密封风电动门故障 E grinding cold air plug board door seal electric door fault 2018.08.27 2019.09.02

18 锅炉 C磨消防蒸汽气动阀门内漏 C mill fire steam pneumatic valve internal leakage 2018.08.27 2019.08.31

The DCS display of oil level in induced draft fan oil tank is quite different from that in
19 锅炉 引风机油箱油位DCS显示与就地相差较大 situ 2018.08.27 2019.09.01

The left side is higher than the inlet flue gas pressure, the left side low temperature
20 锅炉 左侧高过入口烟气压力、左侧低温再热器入口烟气压力不准 reheater inlet flue gas pressure is not allowed 2018.08.27 2019.09.01

DE layer #3 oil fire detection can not detect the flame, resulting in the oil gun can not
21 锅炉 DE层#3角油火检无法检测到火焰,导致该油枪不能投运 be put into service 2018.08.27 2019.09.01

22 锅炉 两台空预器一次风侧人孔门漏风 Two air precursors leak through the primary wind side manhole door 2018.08.27 2019.08.31

24 热控 AGC和一次调频测点 AGC and primary frequency modulation measuring points 2018.08.27 2019.08.31

25 热控 左侧省煤器出口温度3(40HAC11CT105)测点坏点 Left economizer outlet temperature 3 (40HAC11CT105) bad point 2018.08.27 2019.08.31

26 热控 A磨暖风器后调节阀反馈不准确 A feedback of regulating valve is not accurate after grinding heater 2018.08.27 2019.08.30

27 热控   D磨CO含量测点 40HFC40GH001XC0坏点 D grinding CO content measuring point 40HFC40GH001XC0 bad point 2018.08.27 2019.08.30

28 热控 D磨润滑油油池温度2坏点40HFV40CT106 D grinding lubricating oil pool temperature 2 bad point 40HFV40CT106 2018.08.27 2019.09.02

29 热控 DE层#3角油阀,吹扫阀阀位反馈错误 DE layer #3 Angle oil valve, purge valve position feedback error 2018.08.27 2019.08.30

Low pressure after blowing ash reducing valve, pressure switch setting error, always
30 热控 吹灰减压阀后压力低,压力开关定值错误,始终低报警 low alarm 2018.08.27 2019.08.30

31 热控 发电机供氢流量测点坏点 Generator hydrogen flow measurement point bad point 2018.08.27 2019.09.01

Flue gas pressure (40HBK10CP106) in front of high temperature superheater on side


33 热控  A侧高温过热器前烟气压力(40HBK10CP106)测点超量程 A exceeds the measuring range 2018.08.27 2019.09.01

The flue gas pressure (40HBK10CP107) before the low pressure reheater at side A
34 热控 A侧低压再热器前烟气压力(40HBK10CP107)测点超量程 exceeds the measuring point range 2018.08.27 2019.09.01

A pneumatic valve (40HFC10AA112) at the outlet of gravel coal box of coal mill shows
35 热控 A磨煤机石子煤箱出口气动阀(40HFC10AA112)状态显示故障 failure 2018.08.27 2019.08.30

C grinding machine gravel coal box outlet pneumatic valve (40HFC30AA112) status
36 热控 C磨煤机石子煤箱出口气动阀(40HFC30AA112)状态显示故障 display fault 2018.08.27 2019.08.30

C mill CO content measuring point 40HFC40GH001XC0 is sometimes good and


37 热控 C磨CO含量测点 40HFC40GH001XC0 时好时坏 sometimes bad 2018.08.27 2019.08.30

38 热控 E磨煤机冷一次风关断门(40HFW25AA01)状态显示故障 E coal mill cold primary air closed door (40HFW25AA01) state failure 2018.08.27 2019.08.30

Air cooled constant temperature and humidity air conditioner A return duct humidity
39 热控 风冷恒温恒湿空调机A回风管湿度(00SAC11CQ101A)显示坏点 (00SAC11CQ101A) shows bad point 2018.08.27 2019.09.03

Air cooled constant temperature and humidity air conditioner A return duct flow
40 热控 风冷恒温恒湿空调机A回风管流量(00SAC11CF101)显示坏 (00SAC11CF101) display is bad 2018.08.27 2019.09.03

The air - cooled constant temperature and humidity air - conditioner A shows the bad
41 热控 风冷恒温恒湿空调机A送风管流量(00SAC11CF102)显示坏点 point 2018.08.27 2019.09.03

Temperature and humidity in central control room (00SAC13CQ102A) shows bad


42 热控 集控室温湿度(00SAC13CQ102A)显示坏点 points 2018.08.27 2019.09.03

43 热控 集控室温度(00SAC13CQ102B)显示坏点 Central control room temperature (00SAC13CQ102B) shows bad points 2018.08.27 2019.09.03

44 热控   #4机组第一组屋顶风机状态显示故障 The state of the first group of roof fans of unit 4 shows failure 2018.08.27 2019.09.03

45 热控 码头变B6KV侧断路器状态显示故障 The state of the circuit breaker on the B6KV side of the dock is fault 2018.08.27 2019.09.02

第 1 页,共 2 页
The current at the 6kV side of dock transformer B (40BBB01GH014XQ1) shows the
46 热控 码头变B 6kV侧电流(40BBB01GH014XQ1)显示坏点 bad point 2018.08.27 2019.09.02

第 2 页,共 2 页