You are on page 1of 5

T of input T of output

Volume
flow rate
1 60 52
2 60 53
3 60 54

volume T of input T of output


flow rate
1 33 40
2 32 38
3 32 36

For co currents of hot and cold water

QH
32925.982
28801.461
24684.46
For co-currents of hot and cold water
Hot water
Mean temperature Temperature in specific heat specific heat Density

56 132.8 0.998 4.178 61.498


56.5 133.7 0.998 4.178 61.484
57 134.6 0.998 4.178 61.471

cold water
Mean temperature temperature in specific heat specific heat Density

36.5 97.7 0.997 4.174 61.984


35 95 0.997 4.174 62.01
34 93.2 0.997 4.174 62.03

d cold water

Qc QH-Qc
29010.26002 3915.72238
24876.2052 3925.2556
16589.47952 8094.98008
Density QH=ρVCp(T -T )

985.1 32925.9824
984.8 28801.4608
984.7 24684.4596

Density Qc=ρVCp(T - T )

992.89 29010.26002
993.3 24876.2052
993.62 16589.47952
volume flow rate

1
2
3

Volume flow rate VS Ener

35000
32925.9824
29010.26002
30000

25000 2487

Qc 20000
and
QH 15000
(KJ/min) 10000

5000

0
0.5 1 1.5

volume fl

VOLUME FLOW RATE


Qc QH

29010.26002 32925.9824
24876.2052 28801.4608
16589.47952 24684.4596

Volume flow rate VS Energies of hot and cold water

000
32925.9824
29010.26002 28801.4608
000
24684.4596
000 24876.2052

000
16589.47952
000

000

000

0
0.5 1 1.5 2 2.5 3 3.5

volume flow rate (L/min)

VOLUME FLOW RATE VS Qc Qh vs V

You might also like