You are on page 1of 9

ATGB 3644 : DRAINAGE WORKS

Taking-Off List

MyCESMM Code
ITEM DESCRIPTIONS Unit CODE
& Rules

Drain excavation, in earth,


A 300mm nominal diameter m Q111 D1, C1, A1, A3
HRGW drain
Drain excavation, extra for
B m3 Q121 M3
excavation in rock. (Provisional)

Drain excavation, excavation for


C m3 Q141 D1,C1,A1,A3
sump, earth, 1560mm x 1530mm
Drain excavation, excavation for
D culvert, in earth, 600mm nominal m3 Q151 D1,C1,A1,A3
diameter,
Surface drain, roadside drain,
E 300mm diameter HRGW drain, m Q230 C4,A6
1070mm wide
Drain cover, precast concrete,
F m Q510 C8, A12
760mm wide x 100mm thick
Brick sump, 1560mm x 1530mm
G x 1.20m deep, including heavy nr Q710 C10, A14
duty mild steel
Culvert, precast concrete pipe
H culvert, single, 600mm nominal m Q611 C9, A13
diameter
TAKING OFF PAPER
Page 1
Index No. Job No. Drainage Works
Project LECTURE
ATGB BTQS3034
3644 Drawing No.

A Notes :
Drain excavation, in earth,
300mm nominal diameter HRGW D1, C1, A1, A3
drain, along Jalan Mat Kilau 36/76,
1070mm wide, depth n.e. 1.5m as
shown on drawing no:
CKT / DR/ 1-3 commencing from
original surface level.
Q111

Max Depth
8.80
7.63
1.17 * n.e 1.50m

Width
610 Drain width
460 Side brick wall
1070

Total Length
94000

94.00 94.00 m A-B Drain

B
Drain excavation, extra for M3
excavation in rock. (Provisional) Just allow 1m³ quantity only in order
for contractor to put in price. (Provisional)
1.00 Q121 stated there means that when site have a lot
1.00 of excavation in rock, contractor is allow to
1.00 1.00 m³ submit re-measurement quantity of that
particular item

Tkn. Chkd. Sqrd. Chkd. Abst. Chkd.


TAKING OFF PAPER
Page 2
Index No. Job No. Drainage Works
Project LECTURE
ATGB BTQS3034
3644 Drawing No.

C Notes :
Drain excavation, excavation for D1,C1,A1,A3
sump, earth, 1560mm x 1530mm Based on detail drawing formula stated :
brick sump, commencing from Length = WD+460
original surface Width = WD+760
Q141

Length (Drain Side)


610
230
230
460
1530

Width (Culvert Side)


600
100
100
760
1560

Depth
8.8 (original level)
- 7.6 (Sump B invert level SIL)
1.2
+ 0.025 (drain thickness)
+ 0.15 (base below drain)
+ 0.23 (concrete base)
+ 0.05 (lean concrete)
1.66

1.53 Sump B
1.56
1.66 3.96 m³

Tkn. Chkd. Sqrd. Chkd. Abst. Chkd.


TAKING OFF PAPER
Page 3
Index No. Job No. Drainage Works
Project LECTURE
ATGB BTQS3034
3644 Drawing No.

D Notes :
Drain excavation, excavation for D1,C1,A1,A3
culvert, in earth, 600mm nominal Based on detail drawing formula stated :
diameter, precast concrete Length = WD+460
culvert, 1100mm wide, Width = WD+760
commencing from original
surface
Q151

Length
12000

Width
600 (Culvert Diameter)
100 (Culvert wall/thickness)
100 (Culvert wall/thickness)
150 (Concrete Surround)
150 (Concrete Surround)
1100 Overall Width

Average Depth
7.60 Invert Level 1
7.57 Invert Level 2
15.17 ÷
2
7.585 Average IL * to nearest 2 decimal point
Therefore; Depth
8.80 Original surface level
- 7.59 Average IL
1.22
+ 0.10 (Culvert wall thickness 100mm)
+ 0.20 (Concrete base 200mm)
12.00 + 0.05 (Lean concrete 50mm)
1.10 1.57 Average Depth
1.57
20.72 m³ Pipe Culvert b18-b19

Tkn. Chkd. Sqrd. Chkd. Abst. Chkd.


TAKING OFF PAPER
Page 4
Index No. Job No. Drainage Works
Project LECTURE
ATGB BTQS3034
3644 Drawing No.

E Notes :
Surface drain, roadside drain, C4,A6
300mm diameter HRGW drain,
1070mm wide and average
1135mm high x 230mm thick
common brick side wall as
shown on drawing no. CKT/DR/2

Q230

Width
610 Drain width
460 Side brick wall
1070

Depth
8.10 Invert Level 1
7.63 Invert Level 2
15.73 ÷2
7.865 Average IL * to nearest 2 decimal point

Therefore;
Depth
- 8.80 Original level
7.87 Average IL
0.94
0.15 concrete base 150mm
0.05 lean concrete 50mm
1.135 Average Depth
to Invert Level

94.00 94.00 m A-B Drain

Tkn. Chkd. Sqrd. Chkd. Abst. Chkd.


TAKING OFF PAPER
Page 5
Index No. Job No. Drainage Works
Project LECTURE
ATGB BTQS3034
3644 Drawing No.

F Notes :
Drain cover, precast concrete, C8, A12
760mm wide x 100mm thick as
shown on drawing no CKT/DR/2-3

Q510
Width
610
75
75
760

94.00 94.00 m A-B Drain

G
Sump, brick, 1560mm x 1530mm C10, A14
x 1.20m deep, including heavy
duty mild steel grating as shown
on drawing no : CKT/DR/4-5

Q710

1 1 nr Sump B

Tkn. Chkd. Sqrd. Chkd. Abst. Chkd.


TAKING OFF PAPER
Page 6
Index No. Job No. Drainage Works
Project LECTURE
ATGB BTQS3034
3644 Drawing No.

H Notes :
Culvert, precast concrete pipe C9, A13
culvert, single, 600mm nominal
diameter, Class X as shown on
drawing no : CKT/DR/6-8

Q611

12.00 12.00 m b18-b19 Pipe culvert

Tkn. Chkd. Sqrd. Chkd. Abst. Chkd.


BILLS OF QUANTITIES
CLASS Q : DRAINAGE WORKS

ITEM CODE DESCRIPTIONS UNIT QTY RATE AMOUNT

A Q111 Drain excavation, in earth, 300mm m 94


nominal diameter HRGW drain,
along Jalan Mat Kilau 36/76,
1070mm wide, depth n.e. 1.5m as
shown on drawing no: CKT / DR/ 1-
3 commencing from original
surface level.

B Q124 Drain excavation, extra for m3 1


excavation in rock. (Provisional)
C Q131.1 Drain excavation, excavation for m3 4
sump, earth, 1560mm x 1530mm
brick sump, commencing from
original surface

D Q131.2 Drain excavation, excavation for m3 21


culvert, in earth, 600mm nominal
diameter, precast concrete culvert,
1100mm wide, commencing from
original surface

E Q230 Surface drain, roadside drain, m 94


300mm diameter HRGW drain,
1070mm wide and average
1135mm high x 230mm thick
common brick side wall as shown
on drawing no. CKT/DR/2

F Q510 Drain cover, precast concrete, m 94


760mm wide x 100mm thick as
shown on drawing no CKT/DR/2-3

G Q710 Sump, brick, 1560mm x 1530mm x nr 1


1.20m deep, including heavy duty
mild steel grating as shown on
drawing no : CKT/DR/4-5
H Q611 Culvert, precast concrete pipe m 12
culvert, single, 600mm nominal
diameter, Class X as shown on
drawing no : CKT/DR/6-8
Total BF to Summary :

You might also like