SIZING OF PRODUCTION AND TEST MANIFOLDS.

PROJECT PC Puesto Hernández


DATA Colector # 10 Pozos Producción año 1
IDENTIFICATION PRODUCTION MANIFOLD
OPERATING PRESSURE,PSIG 35.58
OIL RATE(BPD) 4974.01 CRUDE API 30
WATER RATE (BPD) 19525.51 OPER.PRESS. (PSIA) 50.2759923
GOR(SCF/BBL) 69.95 OPERATING TEMP (F) 104
GAS MW 40.049 OPERATING TEMP.(R) 564.00
GAS SG 1.38 OIL VISCOSITY (CP) 7.07
WATER SG 1.002 GAS VISCOSITY (CP) 0.009
COMP FACTOR Z 1.00 WATER VISCOSITY (CP) 0.656
EROTIONAL VELOCITY
FACTOR C 160 NON- CONTINOUS SERVICE C=125
GOR (ACF/BBL) 22.18 CONTINOUS SERVICE C=100
RESULTS C SERV. W/SAND/OTHER SOLIDS C=80

OIL SG 0.88
OIL DENSITY 54.67 LB/FT3
GAS DENSITY 0.333 LB/FT 3
GAS FLOW a P,T 1.277 FT3/SEG TOTAL VOL. FLOW (FT3/SEG) 2.869
OIL FLOW 0.323 FT3/SEG
WATER FLOW 1.269 FT3/SEG MIXTURE DENSITY (LB/FT3) 33.905
MAX EROTIONAL VEL. 27.48 FT/SEG SHALL BE >10 FT/SEG
MASS GAS FLOW 0.426 LB/SEG
WATER MASS FLOW 79.181 LB/SEG
OIL MASS FLOW 17.673 LB/SEG
TOTAL MASS FLOW 97.280 LB/SEG 350,206.68 LB/HR
TOTAL VOLUM. FLOW 2.869 FT3/SEG
AVERAGE DENSITY 33.905 LB/FT 3 TOTAL MASS FLOW/TOTAL VOL FLOW

ASSUME DIAMETER 8 INCHES SCHDULE 40


7.981
SECTIONAL AREA 50.03 INCH 2

ACTUAL VELOCITY 8.26 FT/SEG SHALL BE LOWER THAN MAX. EROTIONAL VELOCITY
MIN.REQUIRED AREA 15.04 IN 2 SHALL BE LESS THAN B35 VALUE
MIN DIAMETER 4.38 INCHES SHALL BE LOWER THAN ASSUMED DIAM.
THE SELECTED DIAMETER IS O.K. *********,CHECK FOR PRESSURE DROP
PRESSURE DROP 0.56 PSI/100 ft
THE PRESSURE DROP IS O.K. ************

LENGTH OF MANIFOLD
INPUT QTY OF FLOWLINES 10
INPUT SPACING* PIPES 2 FT
FLOWLINES SIZE (IN) 8 LENGTH(FT) 22

C.F 04/02/2020

You might also like