Professional Documents
Culture Documents
COLUMNS
Review material test certificates/Manufacturer Test Review TC/MTC’s
certificates of all the structural members & bought out
1
items as per drawing.
Diagonal check
Allowable tolerance + 10 mm
D= S2+W2
8
S= Span, W=column to column distance
ROOF GIRDER
Random Visual inspection of roof girders to be carried out Random visual check
9
before erection with ref mark no. As per ISO/Drg
10 Torque values
Torquring check for roof girder assembly
11 Random hole to hole dimension check for roof girder end As per Drg
plate
After erection of roof girders and fixing of portal check
12 proper tightening of all nuts with washers As per Approved Specification
CRANE GIRDER
RAILS
21 Check rail support clamp bolting As per drawing
22 Rail Elevation Tolerance: + 5mm
Axis checking is to be carried out by Theodolite at every
12mtr with reference to the master girder axis in both Axis: + 5mm
23
corresponding rows
D= S2+W2
S= Span, W=Every 6 meter distance
Check rail to rail offset and rail to rail gap
26 As per approved drawing
Check the surface preparation, painting with the calibrated As per ISO Standard
Elcho meter. Before proceeding for paint check for
structural members, review the documents like surface
28
preparation and painting procedure, Paint batch TC’s
should be reviewed with the original.
Note: The above Tolerance limits are based on Standard codes and approved Drawings.