KONE error code Failure reason

KONE error code ( full version )


Failure reason code

0001 driver long time after a period of the position signal 30/B30 running time does not change.
Immediately stop power off

0004 three consecutive synchronous operation failed. Three consecutive synchronous operation of the
system are not receiving proper leveling signal slowdown after three failed to stop at the end of the
station . Off power

0007 Area 308,030 switch stuck after the start time is not detected falling edge 30/B30 signal. Door
zone has been effective operation of the switch to the destination 30/B30

0008 NVRAM damaged or capacity is not enough when the power transmission capacity is not enough
to detect NVRAM . Replace NVRAM

0014 Area check the circuit did not release any of two consecutive .486.443.1.443:2 without (ACO /
ACL) run to the destination floor , shut off electrical service

0015 Area check circuit does not pull any one .486.443.1.443:2 consecutive times without (ACO / ACL)
run to the destination floor , shut off electrical service

0021 safety circuit fails . Safety circuit input a no voltage is immediately stopped. Safety circuit switched

0022 Hall door barrier. 3 no-voltage input safety circuit stop immediately . Hall door turns

0023 car door lock will not work. Safety circuit voltage input 2 no stop immediately . Door sedan turned

0025 start of system failure when the elevator did not stop the main contactor release does not start .
Main contactor failure row

0026 drive system failure . Driven system detects a fault (v3FCK not light ) does not start. Off power or
play overhaul

0039 shorted 77 buttons stuck. Shorted 77 buttons card refuses to start LCEBOPU board. Until the
release button

0042 car lighting monitor lighting no electricity to run the car to the destination floor. From service until
the signal disappears

0044 closed barrier several attempts . Closed door barrier five times but failed . Door opening does not
go off electricity or playing back door opener repair 0048 remain valid reverse signal lasts more than
one minute to open the door to keep the door closed until the signal disappears electricity

0051 start start invalid 5 times unsuccessful , such as landing door may not shut the door and then try
five automatic recovery

0052 down synchronous switching while effectively .77 U and 77N while effectively stop immediately.
RDF can only start at the end of the station automatically restored

0058 ready to run out. Had requested but the elevator did not start running more than 100 seconds to
stop immediately. Attempt to run off after ten seconds or playing electric acceleration signal 0060V3F16
overhaul did not receive accelerated loss of signal -to-end operation of the drive system power off or
play station overhaul

0071 district loss of signal . After several layers 61U / N when the rising edge of the signal can not be
found 30/B30 run to the destination floor. Door shut without electricity or playing overhaul

0072 61U Signal stuck .61 U signal after leaving the gate area is still not released for some time to run
to the destination floor. Then open to the lowest floor as still stuck, then shut off electrical service or
repair 0071 hit area through several layers of signal loss 61U / N can not be found when the rising edge
of the signal to run 30/B30 destination floor . door shut without electricity or playing overhaul

0073 61N signal stuck. Passes through several layers of the door area. 61N can not find the rising edge
of the signal . Off electricity or playing overhaul
0073 61N signal stuck. Passes through several layers of the door area. 61N can not find the rising edge
of the signal . Off electricity or playing overhaul

0074 61N signal stuck .61 N signal after leaving the gate area for some time still not released. Off power
or play overhaul

0075 61U Signal stuck. Passes through several layers of the door area. 61U can not find the rising edge
of the signal . Off electricity or playing overhaul
Automatic recovery after the 0076 area surveillance for the first time not to release without releasing
(ADO / ACL) ( allowed ) to run to the destination floor 15 seconds 486.443:1.443:2 any runtime

0077 open limit fault ( been ineffective ) . Door open , but can not receive a signal
Button stuck in the 0078 car . Buttons stuck inside any car more than 60 seconds to cancel the twist
service until button to return to normal

0079 Outbound button stuck. Arbitrary outbound button stuck more than 60 seconds to cancel the
twisted services back to normal until the button
Monitor automatically restored 0082 area does not pull no first pull (ADO / ACL) ( allowed ) to run to the
destination floor 15 seconds after running either 486.443:1.443:2

0083 to calculate the position of losing the signal does not match with the wells run to the end station

0084 open limit fault ( been effectively ) shut the door open but still received signal

0089 Hall landing door locks open circuit monitoring ( non- car position ) run to the destination floor .
Shut off electrical service or overhaul fight

0145 EBD EBD equipment damage

0146 EBD EBD battery cell damage


Drive failure

0101 drivers to stop driving the system detects a fault the elevator stopped to check the drive shaft
failure

0102 motor overcurrent

0103 braking resistor braking resistor is damaged, check the brake resistor

0104 motor overheated motor thermistor

0105 AC power supply intermediate DC voltage is too low

0106 V3F bad

0107 load bearing device failure signal voltage is less than 0.6V regulator load device

0108 motor / tachometer speed reverse polarity wrong / bad car balance / load allowed / not open brake
/ drive parameters right / overspeed

0109 Position location is lost is lost drive system under investigation deceleration , leveling switch

0110 radiator overheating. Overheating radiator driver module


The drive control process failures

0111 deck 61: N at 61: Under U 61U / N swapped Chapin layer switching sequence

0112 61: U / N overlapping layer switch position too Chapin

0113 simultaneous switching error error synchronous switch synchronous switch synchronous switch
failure investigation

0114 floor distance is too short to check the position of the magnet

0115 the proportion of errors

0116 test runs to learn counting error floor redone floors unsuccessful learning
Network failure
A side door / 3 side

1101 bad circuit board input board is damaged, electrical wiring errors can not be contacted or not
normal deceleration stop layer , close contact does not move again until the

1202 / 2201 first board fault circuit board is damaged , electrical wiring errors can not be contacted or
did not resume normal service until the single staircase contacted again

1202 / 2202 second board fault circuit board is damaged , electrical wiring errors can not be contacted
or did not resume normal service until the single staircase contacted again

1203 / 2203 The third board fault circuit board is damaged , electrical wiring errors can not be contacted
or did not resume normal service until the single staircase contacted again

1301 / 2301 output boards bad circuit board is damaged, electrical wiring errors can not be contacted or
did not reach the target layer , the door does not move again until the contact

1401 / 2401 first board fault circuit board is damaged , electrical wiring errors can not be contacted or
did not resume normal service operation signal is detected by the first xx 14xx/24xx boards fault circuit
board is damaged , electrical wiring errors can not be contacted or did not resume normal service
operation signal detection by

1501 / 2501 first board fault circuit board is damaged , electrical wiring errors can not be contacted or
did not resume normal service operation signal is detected by
15xx/25xx first xx boards fault circuit board is damaged , electrical wiring errors can not be contacted or
did not resume normal service operation signal is detected by

1601 bad circuit board expansion board is damaged, electrical wiring errors can not be contacted or did
not resume normal service until the single staircase contact again on

1701 / 2701 first board fault circuit board is damaged , faulty wiring or no power can not be contacted
again until contact on
17xx/27xx first xx boards fault circuit board is damaged , faulty wiring or no power can not be contacted
again until contact on

The 102 is an over-current,it may happen when you try pulling through the Brake. you may
want to make sure the Brakes are picking. Make sure they pick on a re-level. A 21 will be
thrown almost every time you open the Safety circuit or go on inspection service. It will
also happen when you have an error like a 102.

One other thing that can cause a 102 is a stuck Buffer Test Button. Usually though it is the
.Over-Current error