You are on page 1of 4

DESIGN FOR TWO WAY SLAB

CASE 4

PROPERTIES

Movable Partition 0.5 kPa


fc' 21 Mpa
fy 276 Mpa
Ceiling 0.05 kPa
Electrical and Plumbing 1.6 kPa
H 100 mm
Concrete 23.6 kN/m^3
Floor Finish 0.77 kPa
WDL 5.28 kpa
WLL 1.9 kpa

Wu DL LL
2015 1.2 1.6
6.336 3.04 9.376 kpa
9.376 kpa
2015 6.336 3.04 9.376 Kn/m

La(short) 4.765 Lb(long) 5.071


m 0.939657
0.940 Ca 0.037 0.940 Cb 0.018

Positive Moments DEAD LOAD C*Wu*L^2


Short Direction Ca 0.037 Ms 5.32283 kn-m
Long Direction Cb 0.018 Mb 2.93275 kn-m

La(short) 4.765 Lb(long) 5.071


m 0.939657
0.940 Ca 0.045 0.940 Cb 0.022

Positive Moments LIVE LOAD C*Wu*L^2


Short Direction Ca 0.045 Ms 3.10607 kn-m
Long Direction Cb 0.022 Mb 1.71982 kn-m
Total Positive Moments
Short Direction 8.428906087 kn-m
Long Direction 4.652570938 kn-m

La(short) 4.765 Lb(long) 5.071


m 0.939657
0.940 Ca 0.068 0.940 Cb 0.032

Total Negative Moments C*Wu*L^2


Short Direction Ca 0.068 Ms 14.4761 kn-m
Long Direction Cb 0.032 Mb 7.71534 kn-m

Total Negative Moments


Short Direction 14.47612489 kn-m
fc' 21 h 100 mm
fy 276 cover 20 mm
phi 0.9 rebar 12 mm
b 1000 d 74 mm
B1 0.85
Ms=(phi)(fc')(b)(d^2)(w)(1-.59w)

a 0.59 b + 1.5411
b -1 - 0.1538
c 0.139870806
w 0.1538
ro=w(fc'/fy) 0.0117
ro-min 0.00507
ro-max 0.02356
CRITERIA 0.0117
As=(ro)(b)(d) 866.146091
As=(1000/s)(pi/4)(dia^2)
s=(1000/As)(pi/4)(dia^2) 130.575358 say
Ms-middle strip
200 mm O.C.
Cs-Column strip
450 mm O.C.
Total Negative Moments
Long Direction 7.715335181

fc' 21 h 100 mm
fy 276 cover 20 mm
phi 0.9 rebar 12 mm
b 1000 d 74 mm
B1 0.85

Ms=(phi)(fc')(b)(d^2)(w)(1-.59w)

a 0.59 b + 1.6168
b -1 - 0.0782
c 0.074546894
w 0.0782
ro=w(fc'/fy) 0.0059
ro-min 0.00507
ro-max 0.02356
CRITERIA 0.00595
As=(ro)(b)(d) 440.020174
As=(1000/s)(pi/4)(dia^2)
s=(1000/As)(pi/4)(dia^2) 257.027614 say

Ms-middle strip
200 mm O.C.
Cs-Column strip
450 mm O.C.
Total Positive Moments
Short Direction 8.428906087

fc' 21 h 100 mm
fy 276 cover 20 mm
phi 0.9 rebar 12 mm
b 1000 d 74 mm
B1 0.85
Ms=(phi)(fc')(b)(d^2)(w)(1-.59w)

a 0.59 b + 1.6091
b -1 - 0.0858
c 0.081441539
w 0.0858
ro=w(fc'/fy) 0.0065
ro-min 0.00507
ro-max 0.02356
CRITERIA 0.00653
As=(ro)(b)(d) 482.996749
As=(1000/s)(pi/4)(dia^2)
s=(1000/As)(pi/4)(dia^2) 234.15755 say
Ms-middle strip
200 mm O.C.
Cs-Column strip
450 mm O.C.

Total Positive Moments


Long Direction 4.652570938

fc' 21 h 100 mm
fy 276 cover 20 mm
phi 0.9 rebar 12 mm
b 1000 d 74 mm
B1 0.85

Ms=(phi)(fc')(b)(d^2)(w)(1-.59w)

a 0.59 b + 1.6487
b -1 - 0.0462
c 0.04495394
w 0.0462
ro=w(fc'/fy) 0.0035
ro-min 0.00507
ro-max 0.02356
CRITERIA 0.00507
As=(ro)(b)(d) 375.362319
As=(1000/s)(pi/4)(dia^2)
s=(1000/As)(pi/4)(dia^2) 301.301782 say
Ms-middle strip
200 mm O.C.
Cs-Column strip
450 mm O.C.
Thus:
12mm Diameter @ 200mm Spacing O.C
12mm Diameter @ 450mm Spacing O.C

You might also like