You are on page 1of 1

¢ POST ¢ POST

NOTE:
SPAN LENGTH = "S"

¢ BOLT SPLICE #1 ¢ BOLT SPLICE #2 ¢ BOLT SPLICE #2 ¢ BOLT SPLICE #1 1. SPANS GREATER THAN 150'-0" SHALL
"L1" "L2" "L3" 'L2" "L1" INCORPORATE AN "L4" MIDSPAN SEGMENT
AND SHALL HAVE TWO "L3" INTERMEDIATE
T SPAN SEGMENTS AND TWO BOLT SPLICE #3.

"¸" "XA" "¸" "XB" "¸"

10.1-A1-3
FALL RESTRAINT. SEE STD.
¢ SPAN PLAN G-95.20 FOR DETAILS

SIGN A 6"ø HANDHOLE AT


SEE DETAIL 1 LIGHT FIXTURE
NIPPLE LOCATION** VMS SIGN B

¢ BEAM
10.1-A1-2

"YB"
"YA"

"YB/2"
"YA/2"
MAX. CAMBER
@ ¢ SPAN
(SEE TABLE)

1½"ø NIPPLE FOR


VMS (AS REQ'D)* SEE DETAIL 2
1"ø NIPPLE FOR
LIGHT FIXTURE ¢ LIGHT FIXTURE 6"ø HANDHOLE AT VMS (TYP.)
(AS REQ'D)* SEE STD. PLAN NIPPLE LOCATION** 10.1-A1-3

VERT. CLR. (TYP.)


G-90.40 (TYP.)
MAINTENANCE WALKWAY (TYP.) ISOLATION SWITCH
Last revised on : 4/26/2016

H = "¸"

20'-0" MIN.
SEE STD. PLAN G-95.20. NEMA 3R TERMINAL

H = "¸"
FOR DETAILS (NOTE PLATFORM REQUIRED CABINET (FAR SIDE)
@ ALL ACCESS DOORS)
ERECT VERTICAL ±¼" @
SURVEY LINE ¢ BEAM ( TYP. BOTH LEGS)

"¸" OFFSET LEFT "¸" OFFSET RIGHT

ELEV. "A"
"¸" "¸" "¸" "¸" "¸" "¸" "¸" (BOTTOM OF
LANE LANE GORE LANE SHLD. BASE PLATE)
"¸"
ELEV. "¸" BARRIER SHAPE CAP
(BOTTOM OF SEE SHEET 10.1-A5-1
BASE PLATE)
ELEV. "¸"
ELEV. "¸" ELEV. "¸"
ELEV. "¸"
"Þ"
SEE DETAIL 3 "¸"
FOUNDATION TYPE 1,
SEE SHEET 10.1-A4-1 ELEVATION 10.1-A1-2
SIGN BRIDGE NO. _ - STA. _______
THE MAXIMUM SIGN AREA ON THIS
notes to the designer STRUCTURE SHALL BE ___ SQ. FT. FOUNDATION TYPE 2 OR 3
SEE BR. SHT. 10.1-A4-3
delete all lighting and electrical
details, callouts & notes if no * CONTRACTOR TO VERIFY NIPPLE
electrical items required on the LOCATION TO MATCH VMS SIGN
sign structure, except conduit in OR LIGHT FIXTURE CONDUIT
foundation. LOCATIONS, PRIOR TO SIGN HORIZONTAL ¢ SPAN
STRUCTURE FABRICATION. NO

¢ BEAM
"¸" ± 1" CAMBER
existing roadway lines dashed and FIELD WELDING OR DRILLING
new roadway is solid. SHALL BE PERMITTED. 0.75 CAMBER

"¸" is shown where dimensions are ** HANDHOLE IS ONLY REQUIRED "S"/4


SHEET

required. IF NIPPLE LOCATION IS GREATER "S" (TYP)


THAN 1'-6" FROM ANOTHER HAND
remove notes that are not applicable. HOLE LOCATION.
BEAM CAMBER DIAGRAM
10.1-A1-1
JOB NO.

Bridge Design Engr. M:\STANDARDS\Sign Bridges\MT_SIGN_BRIDGE_LAYOUT.MAN


Supervisor STATE FED. AID PROJ. NO.
Designed By
10 WASH.
Checked By
Detailed By
JOB NUMBER
Bridge Projects Engr.
SR

Prelim. Plan By MONOTUBE SIGN BRIDGE


Architect/Specialist DATE REVISION BY APP'D LAYOUT
Wed May 25 07:59:16 2016