You are on page 1of 3

SAUDI ARAMCO ID/PIEU-24-July-2018 - REV.2018.06.00 (Standards Cutoff - June 30,2018) Rev.2018.06.

00 30-Jun-18
SATR NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO TEST REPORT
Re-instatement Checklist (Form) SATR-A-2011 24-Jul-18 MECH
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION TEST SYSTEM No./Test Pack No. PLANT NO.

DRAWING NUMBER (P&ID/ISO) / REV. No. PRESSURE TEST DIAGRAM NATURE OF TEST WORK PERMIT REQD?

SAUDI ARAMCO TIP (SATIP) NUMBER SATIP Activity No. SUPPORTING SAIC Number SAIC QR No.

Notes:
1) This Form shall be used in conjunction with an applicable Reinstatement Procedure for all Test Packages (SAEP-1160).
2) "B" items from Pre-Test Checklist are cleared after testing during re-instatement to close & certify Test Pkgs.
3) Any items not completed during the re-instatement
shall be added to Mechanical Completion Punchlists and submitted to Saudi Aramco (FEIL). ETC = Estimated Time of Completion (Affects
lay-up selections)

Verified Certify Test


Item Description Reference
Origi- ETC
complete
Concur
Package
# (Use with applicable Re-Instatement Procedure) nator (Note 3) (PID)
by QC Complete
1 Seal weld threaded nipples from headers to root valves at
locations (hydrocarbon service) Std drawing
AB-036521 Sht
01 Rev 09

2 The free movement of unrestrained piping, both in axial and


lateral directions, shall be controlled and limited by properly SAES-L-310
located guides and anchoring points to within acceptable bounds. Para 15.2.1

3 For all sizes NPS 4 inch and above, a turbulence-free minimum


distance of 5 pipe diameters upstream and 2 pipe diameters
downstream of every check valve shall be maintained. No pipe
fittings such as elbows, reducers, tees, etc., or flow restricting
devices such as orifices, control valves, etc., shall be installed in SAES-L-108
these zones unless Para 6.3.4
specifically approved by the Chairman of the Valves Standards
Committee.

4 Check valve is oriented in the wrong direction (flow arrow).


Reverse check valve to assure correct flow direction. SAES-L-108
(Note: Valve to be re-positioned after test.) Para 6.2.2.(e)

5 The minimum spacing between lines supported on sleepers or


pipe racks shall be as shown on Standard Drawing AB-036207. SAES-L-310
Para 12.2

6
NOTES:

A. Indicate " No Punch items. " if there are


no punch list items to be recorded.
All above items have been completed on Reinstatement per procedure and test package is
certified complete:
Remarks:

Contractor / Third-Party Saudi Aramco


Technician Performing Test* PMT Representative
Test Performed Successfully and Results are Acceptable: T&I Witnessed QC Record Reviewed Work Verified
Name, Title, Department,
Name, Initials and Date:
Company, Initials and Date:

QC Inspector PID Representative


Witnessed Test Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU-24-July-2018 - REV.2018.06.00 (Standards Cutoff - June 30,2018) Rev.2018.06.00 30-Jun-18
SATR NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO TEST REPORT
Re-instatement Checklist (Form) SATR-A-2011 24-Jul-18 MECH
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION TEST SYSTEM No./Test Pack No. PLANT NO.

DRAWING NUMBER (P&ID/ISO) / REV. No. PRESSURE TEST DIAGRAM NATURE OF TEST WORK PERMIT REQD?

SAUDI ARAMCO TIP (SATIP) NUMBER SATIP Activity No. SUPPORTING SAIC Number SAIC QR No.
Quality Record Approved:
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Implementation of Test and Analysis of Results Y = YES N = NO F = FAILED

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU-24-July-2018 - REV.2018.06.00 (Standards Cutoff - June 30,2018) Rev.2018.06.00 30-Jun-18
SATR NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO TEST REPORT
Re-instatement Checklist (Form) SATR-A-2011 24-Jul-18 MECH
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION TEST SYSTEM No./Test Pack No. PLANT NO.

DRAWING NUMBER (P&ID/ISO) / REV. No. PRESSURE TEST DIAGRAM NATURE OF TEST WORK PERMIT REQD?

Item
Description A or B Origi- ETC
Verified
Concur
# (Use with the applicable Pre-Test Punchlist Reference complete
Item nator (Note 4) (PID Inspector)
Checklist) by QC

Saudi Aramco: Company General Use