You are on page 1of 11

Best Pneumatics 4

Pressure Gauge Guide


General Purpose Pressure Gauge: G쏔 ······························· P.1.15-2

Equipment
Oil Free/External Parts Copper Free Pressure Gauge: G46E ···· P.1.15-8

Air Line
Pressure Gauge for Clean Regulator: G46-쏔-쏔-SR ·············· P.1.15-9

1.15-0
Pressure Gauge Guide
General Purpose Pressure Gauge
Size Model
Indication Gauge range Connecting Material Indication units (1)
precision Attachment (2)
(O.D.) (Type) MPa kgf/cm2 thread Case Clear cover Stud MPa MPa & kgf/cm2
%FS
General purpose
R(PT) 1/8
G15 0 to 1.0
ø15 Male thread,
(DTtype) Zinc Zinc
M5 Female
die cast Poly- die cast
5
(Sun-coat carbonate (Sun-coat
P.1.15-2
G27 R(PT)1/16 treated) treated)
ø26 0 to 1.0
Male thread
(DTtype)

With limit indicator


0 to 0.2
G36 0 to 0.4 Rolled steel
(DTtype) (Black Poly-
ø37 GA36
3 0 to 0.7 R(PT)1/8
melamine carbonate
Brass P.1.15-4
(ATtype) 0 to 1.0 painted)
0 to 1.5
With limit indicator
G46 0 to 0.2 0 to 1 R(PT)1/8 Cover
(DTtype) 0 to 0.4 0 to 4 R(PT)1/4 Rolled steel ring ass'y
(Black Poly-
ø42 3 0 to 0.7 0 to 7
melamine carbonate
Brass P.1.15-5
GA46 0 to 1.0 0 to 10 1 painted)
R(PT) /8
(ATtype) 0 to 1.5 0 to 15

0 to 0.2 0 to 2
0 to 0.3 0 to 3
G43 0 to 0.4 0 to 4 R(PT)1/8 Stainless
ø43
(DTtype)
3
0 to 0.6 0 to 6 R(PT)1/4 steel
Glass Brass P.1.15-6
0 to 0.7 0 to 7
0 to 1.0 0 to 10
Note 1) Consult SMC for psi and bar scale indication and connecting thread "NPT".
Note 2) Possible for use in a panel mounting.

Oil Free/External Parts Copper Free Pressure Gauge


Size Model Indication Gauge range Connecting Material Indication units (1)
Attachment
(O.D.) (Type) precision MPa thread Case Clear cover Stud MPa MPa & kgf/cm2
%FS
With limit indicator
Rolled steel Brass
0 to 0.2 Poly- Electroless
0 to 0.4 R(PT)1/8 (Black Cover
ø42
G46E
(DT type)
3 0 to 0.7
melamine carbonate
R(PT)1/4 painted) (Hard coated)
nickel
plated
ring ass'y P.1.15-8
0 to 1.0
Oil free (Degreased)
Note 1) Consult SMC for psi and bar scale indication and connecting thread "NPT".
Note 2) Possible for use in a panel mounting.

Pressure Gauge for Clean Regulator


Size Model Indication Gauge range Connecting Material Indication units (1)
Attachment (2)
(O.D.) (Type) precision MPa thread Case Clear cover Stud MPa MPa & kgf/cm2
%FS
With limit indicator
SUS
304 Poly-
0 to 0.2 SUS
G46-쏔-SR (Black carbonate
0 to 0.4
ø42
(DT type) 3
0 to 0.7
R(PT)1/4 melamine (Hard coated) 316 P.1.15-9
painted)
0 to 1.0
Oil free/Water free (2)
Note 1) Consult SMC for psi and bar scale indication and connecting thread "NPT".
Note 2) Refer to the p.1.15-8 for further information.

1.15-1
Pressure Gauge Guide

General Purpose Pressure Gauge


G15 (DT type)/G27 (DT type) ø15
O.D.:
ø26

RoHS
Standard Specifications
Model G15 G27
Type Back side thread
Port size (1) R 1
8 : M5 (Female thread) R 1 16
(2) (3)
Fluid Air
G15-10-01 Indication precision (4) ±5% F.S. (Full span)
G27-10-R1
Case (Surface treatment) Zinc die-casted (Black graphite coated)
Clear cover Polycarbonate
Material
Stud (Surface treatment) Zinc die-casted (Black graphite coated)
Bourdon tube Brass
Weight (kg) 0.01 0.015
• Caution on handling: When drain or oil, etc. gets into the gauge, it may result in a malfunction.
Note 1) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will
cause product to be damaged. Use a pipe tape for sealing.
Note 2) Water cannot be used as an operating fluid. Because the clearance gap of the air passage of the
Bourdon tube is very small. Water will block the gap and cause a malfunction.
Similarly, when using other fluids, please consult with SMC for fluid compatibility information
concerning possible corrosion and response delay, etc.
Note 3) Avoid freezing as this may cause a malfunction.
Note 4) The guaranteed temperature range is 23°C ±5°C.

Model (Standard)
Pressure range (1) Indication
Model Connection thread
MPa unit
G15-10-01 0 to 1.0 MPa R 1/8, M5 (Female thread)
1
G27-10-R1 0 to 1.0 MPa R 16

Note 1) Do not apply more excessive pressure than max. pressure display. It will be a cause of malfunction.

Other versions of this unit can be made on a Made-to-Order basis.


Model (Made to Order) Please consult with SMC for details, as delivery times may be extended.
Pressure range (1) Indication
Model Connection thread
MPa psi unit
G27-10-M5 0 to 1.0 — MPa M5 (Female thread)
G27-P10-R1-X30 (2) 0 to 1.0 0 to 150 MPa, psi R 1 16
Note 1) Do not apply more excessive pressure than max. pressure display. It will be a cause of malfunction.
Note 2) Under the New Measurement Law, products for overseas use only (SI unit type for use in Japan)

1.15-2
Pressure Gauge Guide

General Purpose Pressure Gauge


G15 (DT type)/G27 (DT type) ø15
O.D.:
ø26

RoHS
How to Order

G 15 10 01
Pressure gauge q w e r


q
Symbol Description Size
G15 G27
+
10 (1) 1.0 MPa 앬 앬

w Max. display pressure
P10 (1), (2) 1.0 MPa, 150 psi — 앪 (3)
Note 1) Pressure other than 1.0 MPa is not
available.
+ Note 2) This symbol must be used with Special
R 1/8: M5 (Female thread) 앬 — specifiction “X30.”
01

e Connection thread R 1/8 — 앬 Note 3) Under the New Measurement Law,
R1 R 1/16 — 앬 products for overseas use only
(SI unit type for use in Japan)
+ Note 4) Wetted parts stainless steel specifications
Special — — 앬 앬

r specification Note 4) X30 Both MPa and psi — 앪 (3)
are not available.
Note 5) Cover ring assembly is not available.

Dimensions (Except Made-to-Order products)


G15-10-01 G27-10- R1
01 21(Width across flats)

18.5 17.5
6.5 11
8.5
ø15

ø26

M5×0.8×5 R1/16(R1/8)
Hex. width across flats 10

R1/8

∗ The dimensions in ( ): Connection thread R 1/8

1.15-3
Pressure Gauge Guide

General Purpose Gauge/With Limit Indicator


G36 (DT type)/GA36 (AT type) O.D.: ø37

RoHS
Standard Specifications
Model G36 GA36
Type Back side thread Vertical side thread
1 1
Port size (1) R 8 (Option M: With M5 female thread) R 8
(2) (4) Air
Fluid
Indication precision (5) ±3% F.S. (Full span)
Case Rolled steel Stainless steel
G36-10-01 (Surface treatment) (Electrodeposition coating black) (Black melamine painted)
Polycarbonate Polycarbonate
Clear cover (3) (Part no.: G36-00-00-4) (Part no.: G36-00-00-3)
Material
Stud Aluminum die-casted
(Surface treatment) (Black disulfide molybdenum coat treated) Brass

Bourdon tube Brass


Weight (kg) 0.04 0.05
Note 1) When installing a pressure gauge, be careful not to fasten too tight. Excessive tightening will result in
damage. Use a pipe tape for sealing.
Note 2) Not applicable to water as fluid because its stub is made from aluminum die-casted. Water may cause
corrosion and block the air passage.
Note 3) Clear cover: G36-00-00-4 is not compatible with G36-00-00-3.
Note 4) Avoid freezing as this may cause a malfunction.
Note 5) The guaranteed temperature range is 23°C ±5°C.

Model (Standard)
Pressure range (1) Indication Connection
Model Note
MPa unit thread
G36-2-01 0 to 0.2
G36-4-01 0 to 0.4
G36-7-01 0 to 0.7 MPa R1 8

G36-10-01 0 to 1.0
GA36-10-01 0 to 1.0
Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.

Other versions of this unit can be made on a Made-to-Order basis.


Model (Made to Order) Please consult with SMC for details, as delivery times may be extended.

Pressure range (1) Indication Connection


Model Note
MPa psi unit thread
G36-P2-01-X30 (2) 0 to 0.2 0 to 30
MPa, psi
G36-P10-01-X30 (2) 0 to 1.0 0 to 150 R1 8

G36-15-01 0 to 1.5 — MPa


Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
Note 2) Under the New Measurement Law, products for overseas use only (SI unit type for use in Japan).

Dimensions
G36-쏔쏔-01(M) GA36-쏔쏔-01

40.5
24.5 24.5
ø37.5

ø37.5
쏔14

7
[M5×0.8×5
35.5

R1/8 Option: For M]

R1/8
쏔12

1.15-4
Pressure Gauge Guide

General Purpose Pressure Gauge/With Limit Indicator


G46(DT type)/GA46(AT type) O.D.: ø42

RoHS
Standard Specifications
Model G46 GA46
Type Back side thread Vertical side thread
Port size (1) R 1/8, R 1/4 (Option M: with M5 female thread)
Fluid (2) (4) Air
Indication precision (5) ±3% F.S. (Full span)
Case Rolled steel Stainless steel
(Surface treatment) (Electrodeposition coating black) (Black melamine painted)
G46-10-02M-C Polycarbonate Polycarbonate
Clear cover (3)
Material Part no.: G46-00-00-4 Part no.: G46-00-00-3
∗ The dimensions in ( ):
Stud Aluminum die-casted
Dimensions Connecting thread R 1/4 Brass
(Surface treatment) (Black disulfide molybdenum coated)
G46-쏔쏔-01 to 02 (M) Bourdon tube Brass
41.5 (44.5) Weight (kg) 0.05 0.075
25.5 Attachment: C Part no.: 1305104-1A
With cover ring —
assembly C2 Part no.: 1305104-9A
ø42.5

쏔14

Note 1) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause
[M5 x 0.8 x 5
product to be damaged. Use a pipe tape for sealing.
Option: For M]
Note 2) Not applicable to water as fluid because its stub is made from aluminum die-casting. Water may cause
corrosion and block the air passage.
R 1/8 (R 1/4)
Note 3) Clear cover: G46-00-00-4 is not compatible with G46-00-00-3.
Note 4) Avoid freezing as this may cause a malfunction.
Note 5) The guaranteed temperature range is 23°C ±5°C.
G46-쏔쏔-01 to 02 (M)-C
G46-쏔쏔-01 to 02 (M)-C2
With cover ring assembly Model (Standard)
(For panel mount) (1)
Pressure range Indication Connection
Type C Model Note
MPa unit thread
(Clear cover is not removable.)
41.5 (44.5) G46-2-01/02 0 to 0.2
3.3
G46-4-01/02 0 to 0.4 1 1
G46-7-01/02 0 to 0.7 R 8, 4

G46-10-01/02 0 to 1.0
MPa —
ø57
ø53

G46-2-01 to 02M 0 to 0.2


G46-4-01 to 02M 0 to 0.4 1 1
R 8, 4
G46-7-01 to 02M 0 to 0.7 M5 (Female thread)
M48 x 2 R 1/8 (R 1/4)

[M5 x 0.8 x 5
G46-10-01 to 02M 0 to 1.0
Option: For M] GA46-10-01 to 02 0 to 1.0 R 1 8, 1
4
Type C2
(Clear cover is removable. The wrench flats protrude.) Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
41.5 (44.5) Panel fitting dimensions
≈6 3.3
Plate thickness Max. 3.5t
3 Other versions of this unit can be made on a Made-to-Order basis. Please consult
R
Model (Made to Order) with SMC for details, as delivery times may be extended.
.5
48

(1)
26

Pressure range Indication Connection


Model Note
ø57
ø53

MPa psi unit thread


G46-2-01 to 02-C/C2 0 to 0.2 —
G46-4-01 to 02-C/C2 0 to 0.4 — 1 1
M48 x 2 R1/8 (R1/4) R 8, 4
[M5 x 0.8 x 5 G46-7-01 to 02-C/C2 0 to 0.7
Option: For M]
— With cover
G46-10-01 to 02-C/C2 0 to 1.0 MPa ring assembly
G46-2-01 to 02M-C/C2 0 to 0.2 —
GA46-쏔쏔-01 to 02 1
G46-4-01 to 02M-C/C2 0 to 0.4 — R 8, 1 4
25.5 (27.5)
G46-7-01 to 02M-C/C2 0 to 0.7 — M5 (Female thread)
G46-10-01 to 02M-C/C2 0 to 1.0 —
7.5 (8.5) G46-P2-01 to 02-X30 (2) 0 to 0.2 0 to 30
ø42.5


G46-P10-01 to 02-X30 (2) 0 to 1.0 0 to 150 1 1
MPa, psi R 8, 4
G46-P2-01 to 02-C/C2-X30 (2) 0 to 0.2 0 to 30 With cover
38 (40)

G46-P10-01 to 02-C/C2-X30 (2) 0 to 1.0 0 to 150 ring assembly


G46-15-02 0 to 1.5 — MPa R1 4 —
쏔12 (쏔14) R 1/8 (R 1/4) Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
Note 2) Under the New Measurement Law, products for overseas use only (SI unit type for use in Japan).

1.15-5
Pressure Gauge Guide

General Purpose Pressure Gauge


G43 (DT type) O.D.: ø43

RoHS
Standard Specifications
Model G43
Type Back side thread
Port size (1) R 1 8, R 1 4
Fluid (2) Air
Indication precision (3) ±3% F.S. (Full span)
Case Stainless steel
Clear cover Glass
Material
Stud Brass
Bourdon tube Brass
G43-10-01
Weight [kg] 0.07
Applicable model IP200, IP8000, IR2000, IR3000, IT2000, IT4000
Note 1) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will
cause product to be damaged.Use a pipe tape for sealing.
Note 2) Avoid freezing as this may cause a malfunction.
Note 3) The guaranteed temperature range is 23°C ±5°C.

Model (Standard)
Pressure range (1) Indication Connection
Model Note
MPa unit thread
G43-2-01 to 02 0 to 0.2 1 1
R 8, R 4
G43-4-01 to 02 0 to 0.4
1
G43-6-01 0 to 0.6 MPa R 8 —
G43-7-01 to 02 0 to 0.7 1 1
R 8, R 4
G43-10-01 to 02 0 to 1.0
Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.

Model (Made to Order)


Pressure range (1) Indication Connection
Model Note
MPa unit thread
G43-2-01 to 02-X2 0 to 0.2 1 1
R 8, R 4
G43-4-01 to 02-X2 0 to 0.4
1 X2: Stud parts
G43-6-01-X2 0 to 0.6 R 8
nickle plated
G43-7-01 to 02-X2 0 to 0.7 1 1
R 8, R 4
G43-10-01 to 02-X2 0 to 1.0
G43-2-01 to 02-X3 0 to 0.2 1 1
R 8, R 4
G43-4-01 to 02-X3 0 to 0.4
MPa 1 X3: Wetted parts
G43-6-01-X3 0 to 0.6 R 8
stainless steel
G43-7-01 to 02-X3 0 to 0.7 1 1
R 8, R 4
G43-10-01 to 02-X3 0 to 1.0
1
G43-2-01-X4 0 to 0.2 R 8
X4: Oil-free
G43-4-01 to 02-X4 0 to 0.4
1 1 (Wetted parts
G43-7-01 to 02-X4 0 to 0.7 R 8, R 4
degreasing)
G43-10-01 to 02-X4 0 to 1.0
Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.

Dimensions (Except Made-to-Order products)


G43-쏔-01 to 02

ø3 Breathing port

∗ The dimensions in ( ): Connection thread R 1/4

1.15-6
Pressure Gauge Guide

General Purpose Pressure Gauge


G43 (DT type) O.D.: ø43

RoHS
How to Order

G 43 10 01
Pressure gauge q w e

Symbol Description G43


+
2 0.2 MPa 앬
3 0.3 MPa 앬
4 0.4 MPa 앬
6 0.6 MPa 앬
7 0.7 MPa 앬

q Max. display pressure 10 1.0 MPa 앬
P2 (1) 0.2 MPa, 30 psi 앪 (2)
P4 (1) 0.4 MPa, 60 psi 앪 (2)
P6 (1) 0.6 MPa, 90 psi 앪 (2)
P7 (1) 0.7 MPa, 100 psi 앪 (2)
P10 (1) 1.0 MPa, 150 psi 앪 (2)
+
01 R 1/8 앬

w Connection thread
02 R 1/4 앬
+
— — 앬 Note 1) This symbol must be used with Special specification “X30.”
X2 Stud parts nickel plated 앬 Note 2) Under the New Measurement Law, products for overseas use only
Special (SI unit type for use in Japan)

e specification X3 (3) Wetted parts stainless steel 앬
Note 3) Movable parts (gear, etc.) inside pressure gauge are made of
X4 Oil-free (Wetted parts degrease washing) 앬 brass.
X30 Both MPa and psi 앪 (2) Note 4) Cover ring assembly is not available.

Dimensions (Except Made-to-Order products)


G43-쏔-01 to 02

ø3 Breathing port

∗ The dimensions in ( ): Connection thread R 1/4

1.15-7
Pressure Gauge Guide

Oil Free/External Parts Copper Free Pressure Gauge


G46E (DT type) O.D.: ø42

RoHS
Standard Specifications
Model G46E
Type Back side thread
Port size (1) R 1 8 , R 1 4 (Option M: with M5 female thread)
Fluid (3) Air
G46E-10-02M Indication precision (4)
±3% F.S. (Full span)
G46E-10-02M-C
Fluid contact part cleaning Wetted parts degrease washing
Case
Rolled steel (Black melamine painted)
∗ The dimensions in ( ): (Surface treatment)
Dimensions Connection thread R 1/4
Clear cover
Polycarbonate (Hard coated) Part no.: G46-00-00-2
Material (Surface treatment)
G46E-쏔쏔-01 to 02 (M)
40.5 (44.5) Stud
Brass (Electroless nickel plated)
쏔12 (쏔14)

24.5 (Surface treatment)


Bourdon tube Brass (2)
ø42.5

Weight (kg) 0.08


[M5 x 0.8 x 5
Option: For M] Attachment: C Part no.: 1305104-1A
R 1/8 (R 1/4) With cover ring
assembly C2 Part no.: 1305104-9A

With cover ring assembly Note 1) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will
cause product failure. Use a pipe tape for sealing.
(For panel mount) Note 2) Bourdon tube and internal movable parts (gear, etc.) are made of brass and are not electrolessly nick-
G46E-쏔쏔-01 to 02 (M)-C el plated. This is not an internally copper-free product.
Type C (Clear cover is not removable.) Note 3) Avoid freezing as this may cause a malfunction.
Note 4) The guaranteed temperature range is 23°C ±5°C.
41.5 (45.5)
3.3

Model (Standard)
Pressure range (1) Indication Connection
ø57
ø53

Model Note
MPa unit thread
G46E-2-01 to 02M 0 to 0.2 1
M48 x 2 R 1/8 (R 1/4) R 8
G46E-4-01 to 02M 0 to 0.4 1
[M5 x 0.8 x 5 MPa R 4 —
Option: For M] G46E-7-01 to 02M 0 to 0.7
M5 (Female thread)
G46E-10-01 to 02M 0 to 1.0
G46E-쏔쏔-01 to 02 (M)-C2
Type C2 Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
(Clear cover is removable. The wrench flats protrude.)
40.5 (44.5) Other versions of this unit can be made on a Made-to-Order basis.
≈4 3.3
Model (Made to Order) Please consult SMC for details, as delivery times may be extended.

Pressure range (1) Indication Connection


Model Note
MPa psi unit thread
G46E-2-02M-C/C2
ø57
ø53

0 to 0.2 — 1
R 8
G46E-4-02M-C/C2 0 to 0.4 — 1
MPa R 4
G46E-7-02M-C/C2 0 to 0.7 —
M48 x 2 R1/8 (R1/4) M5 (Female thread)
[M5 x 0.8 x 5
G46E-10-02M-C/C2 0 to 1.0 — With cover
Option: For M]
R 4
1 ring assembly
G46E-P2-01 to 02M-C/C2-X30 (2) 0 to 0.2 0 to 30
Panel fitting dimensions M5 (Female thread)
Plate thickness Max. 3.5 t MPa, psi 1 1
R 8, 4
3

G46E-P10-01 to 02M-C/C2-X30 (2) 0 to 1.0 0 to 150


R

.5
48

M5 (Female thread)
26

Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
Note 2) Under the New Measurement Law, products for overseas use only (SI unit type for use in Japan)

1.15-8
Pressure Gauge Guide

Gauge for Clean Regulator/With Limit Indicator


G46-쐽-쐽-SR O.D.: ø42

RoHS
Standard Specifications
Model G46-쏔-02-SRA G46-쏔-02-SRB
Type DT type (Back side thread)
Precision ±3% F.S.
Fluid contact part cleaning Precise cleansing General degreasing
Assembly/Adjustment environments Clean room General production line

G46-10-02-SR
Oil/Water free Oil/Water free
Fluid contact part Stainless steel 316
Case Stainless steel 304 (Black melamine plated)
Material
Clear cover Poly-carbonate (Hard coated) Part no.: G46-00-00-2
Inner equipment Brass

Dimensions
Model (Standard)
46.5
Pressure range Connecting
26.5 Model Indication units Note
MPa thread
쏔14

G46-2-02-SRA
0 to 0.2
G46-2-02-SRB
ø42

G46-4-02-SRA
0 to 0.4
G46-4-02-SRB R(PT)1/4
MPa
G46-7-02-SRA
0 to 0.7
G46-7-02-SRB
G46-10-02-SRA
0 to 1.0
G46-10-02-SRB

1.15-9
Pressure Gauge Guide

Procedure for setting the limit gauge indicator Procedure for setting the limit gauge indicator and the setting needle
(1)Before setting the (green) limit indicator, turn the (1)Before setting the limit indicator and the (green) setting
cover counterclockwise (approximately 6 to 7mm) needle, turn the cover counterclockwise (approximately
until it stops. Then, remove by pulling it towards 6 to 7mm) until it stops. Then, remove by pulling it
you. towards you.

(2)Use a flat head screwdriver (with a 2.9mm blade


(2)Use a flat head screwdriver (with a 2.9mm blade width) to set the (green) limit indicator. Be careful
width) to set the (green) limit indicator. Be careful not to bend the other needle or damage the dial
not to bend the other needle or damage the dial plate.
plate.

(3)Before setting the setting needle, use a flat head


screwdriver (with a 2.9mm blade width) to turn the setting
(3)After completing the setting, replace the cover. Fit the screw and set the setting needle to the set pressure.
cover by aligning the cutout in the cover to the groove
Clockwise: increase of setting press.
on the top of the black case. Turn the cover clockwise
Counterclockwise: decrease
(approximately 6 to 7mm) and make sure that the of setting press.
matching mark on the cover is aligned with the groove
on the top of the case.

(4)After completing the setting, replace the cover. Fit the


cover by aligning the cutout in the cover to the groove on
the top of the black case. Turn the cover clockwise
(approximately 6 to 7mm) until it stops. Make sure that the
matching mark on the cover is aligned with the groove on
the top of the case.

Precautions
Be sure to read before handling. Refer to p.0-26 and
0-27 for Safety Instruction and common precautions
on the products mentioned in this catalogue.

Procedure for assembling the cover ring assembly


Selection • General purpose gauge

Caution
qDo not apply high load voltage (current) or surge current as this can
cause the switch to malfunction.
wMake sure that no direct impact or vibrations are applied to the body.
eIf operating under pressure pulsations or in high frequency operations,
contact SMC.
• Gauge with pressure switch

Installation
Caution
qDuring transport and installation, do not apply shock to the product,
such as by dropping doing so will affect its precision.
wIn terms of its installation posture, place it perpendicular to the ground,
1. Remove the small screw (1 position) from the pressure gauge.
with the zero point on the dial of the pressure gauge facing down.
2. Place the cover ring on the pressure gauge.
eDo not install it in an area that is exposed to high temperature or 3. Using the small screw that is provided with the cover ring, install the over
humidity, because doing so will lead to improper operation. ring. The installation torque is 0.3 to 0.5N.m.
rTo screw in the pressure gauge, make sure to turn the gauge by
placing a wrench over the square wrench flats. If the pressure gauge is
screwed in by holding it on some other area, it could lead to air
leakage or damage.

1.15-10