Professional Documents
Culture Documents
Equipment
Oil Free/External Parts Copper Free Pressure Gauge: G46E ···· P.1.15-8
Air Line
Pressure Gauge for Clean Regulator: G46-쏔-쏔-SR ·············· P.1.15-9
1.15-0
Pressure Gauge Guide
General Purpose Pressure Gauge
Size Model
Indication Gauge range Connecting Material Indication units (1)
precision Attachment (2)
(O.D.) (Type) MPa kgf/cm2 thread Case Clear cover Stud MPa MPa & kgf/cm2
%FS
General purpose
R(PT) 1/8
G15 0 to 1.0
ø15 Male thread,
(DTtype) Zinc Zinc
M5 Female
die cast Poly- die cast
5
(Sun-coat carbonate (Sun-coat
P.1.15-2
G27 R(PT)1/16 treated) treated)
ø26 0 to 1.0
Male thread
(DTtype)
0 to 0.2 0 to 2
0 to 0.3 0 to 3
G43 0 to 0.4 0 to 4 R(PT)1/8 Stainless
ø43
(DTtype)
3
0 to 0.6 0 to 6 R(PT)1/4 steel
Glass Brass P.1.15-6
0 to 0.7 0 to 7
0 to 1.0 0 to 10
Note 1) Consult SMC for psi and bar scale indication and connecting thread "NPT".
Note 2) Possible for use in a panel mounting.
1.15-1
Pressure Gauge Guide
RoHS
Standard Specifications
Model G15 G27
Type Back side thread
Port size (1) R 1
8 : M5 (Female thread) R 1 16
(2) (3)
Fluid Air
G15-10-01 Indication precision (4) ±5% F.S. (Full span)
G27-10-R1
Case (Surface treatment) Zinc die-casted (Black graphite coated)
Clear cover Polycarbonate
Material
Stud (Surface treatment) Zinc die-casted (Black graphite coated)
Bourdon tube Brass
Weight (kg) 0.01 0.015
• Caution on handling: When drain or oil, etc. gets into the gauge, it may result in a malfunction.
Note 1) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will
cause product to be damaged. Use a pipe tape for sealing.
Note 2) Water cannot be used as an operating fluid. Because the clearance gap of the air passage of the
Bourdon tube is very small. Water will block the gap and cause a malfunction.
Similarly, when using other fluids, please consult with SMC for fluid compatibility information
concerning possible corrosion and response delay, etc.
Note 3) Avoid freezing as this may cause a malfunction.
Note 4) The guaranteed temperature range is 23°C ±5°C.
Model (Standard)
Pressure range (1) Indication
Model Connection thread
MPa unit
G15-10-01 0 to 1.0 MPa R 1/8, M5 (Female thread)
1
G27-10-R1 0 to 1.0 MPa R 16
Note 1) Do not apply more excessive pressure than max. pressure display. It will be a cause of malfunction.
1.15-2
Pressure Gauge Guide
RoHS
How to Order
G 15 10 01
Pressure gauge q w e r
앬
q
Symbol Description Size
G15 G27
+
10 (1) 1.0 MPa 앬 앬
앬
w Max. display pressure
P10 (1), (2) 1.0 MPa, 150 psi — 앪 (3)
Note 1) Pressure other than 1.0 MPa is not
available.
+ Note 2) This symbol must be used with Special
R 1/8: M5 (Female thread) 앬 — specifiction “X30.”
01
앬
e Connection thread R 1/8 — 앬 Note 3) Under the New Measurement Law,
R1 R 1/16 — 앬 products for overseas use only
(SI unit type for use in Japan)
+ Note 4) Wetted parts stainless steel specifications
Special — — 앬 앬
앬
r specification Note 4) X30 Both MPa and psi — 앪 (3)
are not available.
Note 5) Cover ring assembly is not available.
18.5 17.5
6.5 11
8.5
ø15
ø26
M5×0.8×5 R1/16(R1/8)
Hex. width across flats 10
R1/8
1.15-3
Pressure Gauge Guide
RoHS
Standard Specifications
Model G36 GA36
Type Back side thread Vertical side thread
1 1
Port size (1) R 8 (Option M: With M5 female thread) R 8
(2) (4) Air
Fluid
Indication precision (5) ±3% F.S. (Full span)
Case Rolled steel Stainless steel
G36-10-01 (Surface treatment) (Electrodeposition coating black) (Black melamine painted)
Polycarbonate Polycarbonate
Clear cover (3) (Part no.: G36-00-00-4) (Part no.: G36-00-00-3)
Material
Stud Aluminum die-casted
(Surface treatment) (Black disulfide molybdenum coat treated) Brass
Model (Standard)
Pressure range (1) Indication Connection
Model Note
MPa unit thread
G36-2-01 0 to 0.2
G36-4-01 0 to 0.4
G36-7-01 0 to 0.7 MPa R1 8
G36-10-01 0 to 1.0
GA36-10-01 0 to 1.0
Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
Dimensions
G36-쏔쏔-01(M) GA36-쏔쏔-01
40.5
24.5 24.5
ø37.5
ø37.5
쏔14
7
[M5×0.8×5
35.5
R1/8
쏔12
1.15-4
Pressure Gauge Guide
RoHS
Standard Specifications
Model G46 GA46
Type Back side thread Vertical side thread
Port size (1) R 1/8, R 1/4 (Option M: with M5 female thread)
Fluid (2) (4) Air
Indication precision (5) ±3% F.S. (Full span)
Case Rolled steel Stainless steel
(Surface treatment) (Electrodeposition coating black) (Black melamine painted)
G46-10-02M-C Polycarbonate Polycarbonate
Clear cover (3)
Material Part no.: G46-00-00-4 Part no.: G46-00-00-3
∗ The dimensions in ( ):
Stud Aluminum die-casted
Dimensions Connecting thread R 1/4 Brass
(Surface treatment) (Black disulfide molybdenum coated)
G46-쏔쏔-01 to 02 (M) Bourdon tube Brass
41.5 (44.5) Weight (kg) 0.05 0.075
25.5 Attachment: C Part no.: 1305104-1A
With cover ring —
assembly C2 Part no.: 1305104-9A
ø42.5
쏔14
Note 1) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause
[M5 x 0.8 x 5
product to be damaged. Use a pipe tape for sealing.
Option: For M]
Note 2) Not applicable to water as fluid because its stub is made from aluminum die-casting. Water may cause
corrosion and block the air passage.
R 1/8 (R 1/4)
Note 3) Clear cover: G46-00-00-4 is not compatible with G46-00-00-3.
Note 4) Avoid freezing as this may cause a malfunction.
Note 5) The guaranteed temperature range is 23°C ±5°C.
G46-쏔쏔-01 to 02 (M)-C
G46-쏔쏔-01 to 02 (M)-C2
With cover ring assembly Model (Standard)
(For panel mount) (1)
Pressure range Indication Connection
Type C Model Note
MPa unit thread
(Clear cover is not removable.)
41.5 (44.5) G46-2-01/02 0 to 0.2
3.3
G46-4-01/02 0 to 0.4 1 1
G46-7-01/02 0 to 0.7 R 8, 4
G46-10-01/02 0 to 1.0
MPa —
ø57
ø53
[M5 x 0.8 x 5
G46-10-01 to 02M 0 to 1.0
Option: For M] GA46-10-01 to 02 0 to 1.0 R 1 8, 1
4
Type C2
(Clear cover is removable. The wrench flats protrude.) Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
41.5 (44.5) Panel fitting dimensions
≈6 3.3
Plate thickness Max. 3.5t
3 Other versions of this unit can be made on a Made-to-Order basis. Please consult
R
Model (Made to Order) with SMC for details, as delivery times may be extended.
.5
48
(1)
26
—
G46-P10-01 to 02-X30 (2) 0 to 1.0 0 to 150 1 1
MPa, psi R 8, 4
G46-P2-01 to 02-C/C2-X30 (2) 0 to 0.2 0 to 30 With cover
38 (40)
1.15-5
Pressure Gauge Guide
RoHS
Standard Specifications
Model G43
Type Back side thread
Port size (1) R 1 8, R 1 4
Fluid (2) Air
Indication precision (3) ±3% F.S. (Full span)
Case Stainless steel
Clear cover Glass
Material
Stud Brass
Bourdon tube Brass
G43-10-01
Weight [kg] 0.07
Applicable model IP200, IP8000, IR2000, IR3000, IT2000, IT4000
Note 1) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will
cause product to be damaged.Use a pipe tape for sealing.
Note 2) Avoid freezing as this may cause a malfunction.
Note 3) The guaranteed temperature range is 23°C ±5°C.
Model (Standard)
Pressure range (1) Indication Connection
Model Note
MPa unit thread
G43-2-01 to 02 0 to 0.2 1 1
R 8, R 4
G43-4-01 to 02 0 to 0.4
1
G43-6-01 0 to 0.6 MPa R 8 —
G43-7-01 to 02 0 to 0.7 1 1
R 8, R 4
G43-10-01 to 02 0 to 1.0
Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
ø3 Breathing port
1.15-6
Pressure Gauge Guide
RoHS
How to Order
G 43 10 01
Pressure gauge q w e
ø3 Breathing port
1.15-7
Pressure Gauge Guide
RoHS
Standard Specifications
Model G46E
Type Back side thread
Port size (1) R 1 8 , R 1 4 (Option M: with M5 female thread)
Fluid (3) Air
G46E-10-02M Indication precision (4)
±3% F.S. (Full span)
G46E-10-02M-C
Fluid contact part cleaning Wetted parts degrease washing
Case
Rolled steel (Black melamine painted)
∗ The dimensions in ( ): (Surface treatment)
Dimensions Connection thread R 1/4
Clear cover
Polycarbonate (Hard coated) Part no.: G46-00-00-2
Material (Surface treatment)
G46E-쏔쏔-01 to 02 (M)
40.5 (44.5) Stud
Brass (Electroless nickel plated)
쏔12 (쏔14)
With cover ring assembly Note 1) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will
cause product failure. Use a pipe tape for sealing.
(For panel mount) Note 2) Bourdon tube and internal movable parts (gear, etc.) are made of brass and are not electrolessly nick-
G46E-쏔쏔-01 to 02 (M)-C el plated. This is not an internally copper-free product.
Type C (Clear cover is not removable.) Note 3) Avoid freezing as this may cause a malfunction.
Note 4) The guaranteed temperature range is 23°C ±5°C.
41.5 (45.5)
3.3
Model (Standard)
Pressure range (1) Indication Connection
ø57
ø53
Model Note
MPa unit thread
G46E-2-01 to 02M 0 to 0.2 1
M48 x 2 R 1/8 (R 1/4) R 8
G46E-4-01 to 02M 0 to 0.4 1
[M5 x 0.8 x 5 MPa R 4 —
Option: For M] G46E-7-01 to 02M 0 to 0.7
M5 (Female thread)
G46E-10-01 to 02M 0 to 1.0
G46E-쏔쏔-01 to 02 (M)-C2
Type C2 Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
(Clear cover is removable. The wrench flats protrude.)
40.5 (44.5) Other versions of this unit can be made on a Made-to-Order basis.
≈4 3.3
Model (Made to Order) Please consult SMC for details, as delivery times may be extended.
0 to 0.2 — 1
R 8
G46E-4-02M-C/C2 0 to 0.4 — 1
MPa R 4
G46E-7-02M-C/C2 0 to 0.7 —
M48 x 2 R1/8 (R1/4) M5 (Female thread)
[M5 x 0.8 x 5
G46E-10-02M-C/C2 0 to 1.0 — With cover
Option: For M]
R 4
1 ring assembly
G46E-P2-01 to 02M-C/C2-X30 (2) 0 to 0.2 0 to 30
Panel fitting dimensions M5 (Female thread)
Plate thickness Max. 3.5 t MPa, psi 1 1
R 8, 4
3
.5
48
M5 (Female thread)
26
Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction.
Note 2) Under the New Measurement Law, products for overseas use only (SI unit type for use in Japan)
1.15-8
Pressure Gauge Guide
RoHS
Standard Specifications
Model G46-쏔-02-SRA G46-쏔-02-SRB
Type DT type (Back side thread)
Precision ±3% F.S.
Fluid contact part cleaning Precise cleansing General degreasing
Assembly/Adjustment environments Clean room General production line
G46-10-02-SR
Oil/Water free Oil/Water free
Fluid contact part Stainless steel 316
Case Stainless steel 304 (Black melamine plated)
Material
Clear cover Poly-carbonate (Hard coated) Part no.: G46-00-00-2
Inner equipment Brass
Dimensions
Model (Standard)
46.5
Pressure range Connecting
26.5 Model Indication units Note
MPa thread
쏔14
G46-2-02-SRA
0 to 0.2
G46-2-02-SRB
ø42
G46-4-02-SRA
0 to 0.4
G46-4-02-SRB R(PT)1/4
MPa
G46-7-02-SRA
0 to 0.7
G46-7-02-SRB
G46-10-02-SRA
0 to 1.0
G46-10-02-SRB
1.15-9
Pressure Gauge Guide
Procedure for setting the limit gauge indicator Procedure for setting the limit gauge indicator and the setting needle
(1)Before setting the (green) limit indicator, turn the (1)Before setting the limit indicator and the (green) setting
cover counterclockwise (approximately 6 to 7mm) needle, turn the cover counterclockwise (approximately
until it stops. Then, remove by pulling it towards 6 to 7mm) until it stops. Then, remove by pulling it
you. towards you.
Precautions
Be sure to read before handling. Refer to p.0-26 and
0-27 for Safety Instruction and common precautions
on the products mentioned in this catalogue.
Caution
qDo not apply high load voltage (current) or surge current as this can
cause the switch to malfunction.
wMake sure that no direct impact or vibrations are applied to the body.
eIf operating under pressure pulsations or in high frequency operations,
contact SMC.
• Gauge with pressure switch
Installation
Caution
qDuring transport and installation, do not apply shock to the product,
such as by dropping doing so will affect its precision.
wIn terms of its installation posture, place it perpendicular to the ground,
1. Remove the small screw (1 position) from the pressure gauge.
with the zero point on the dial of the pressure gauge facing down.
2. Place the cover ring on the pressure gauge.
eDo not install it in an area that is exposed to high temperature or 3. Using the small screw that is provided with the cover ring, install the over
humidity, because doing so will lead to improper operation. ring. The installation torque is 0.3 to 0.5N.m.
rTo screw in the pressure gauge, make sure to turn the gauge by
placing a wrench over the square wrench flats. If the pressure gauge is
screwed in by holding it on some other area, it could lead to air
leakage or damage.
1.15-10