SAUDI ARAMCO INSPECTION CHECKLIST
Installation of Wellhead Guard Rails. SAIC-L-2088 30-Apr-17 MECH-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

The Buyer has the Right to inspect all materials and workmanship, and
shall have unrestricted entry to the shop of the Fabricator at all times
while work is being performed. The Buyer may reject improper, inferior,
defective, or unsuitable materials and workmanship. All materials and 12-SAMSS-007
A1
workmanship rejected shall be repaired or replaced by the Fabricator as Para 7.2
directed by the Buyer. The company Inspector shall have access to the
Vendor's facilities to see that SAES-H-100 quality elements are in place
prior to and during blasting, priming and coating

In order to reduce field connections to a minimum, shop assembly shall be


as complete as possible, consistent with the feasibility and economy of
the handling and shipping of the assembled units. Sections or assemblies
too long for shipment shall be provided with field joints of the same
12-SAMSS-007
member strength. Lifting lugs for lifting of fully assembled structural units
A2 Para 6.1.8,6.1.9 &
shall be designed for attachment to primary structural members only.
7.6 e)
Lifting lugs shall be attached by means of a complete joint-penetration
groove weld when the assembly weight exceeds 3000kg.All Lifting Lugs
shall be 100% Magnetic Particle Inspected. Full Penetration Groove welds
in Lifting Lugs shall be 100% Ultrasonic Tested.

All material shall be of New Stock.The minimum thickness of any part of 12-SAMSS-007
A3
the structural shape shall be 5mm. Para 4.1.1 , 4.1.2

All welding shall be in accordance with AWS D 1.1/D1.1M-Structural


12-SAMSS-007
A4 Welding Code-Steel or AWS D 1.3-Structural Welding Code-Sheet Steel,
Cl 6.1.6
as appropriate

Welding procedures and individual welders shall be qualified in


accordance with the requirements of ANSI/AWS D1.1/D1.1M or
12-SAMSS-007
A5 ANSI/AWS D1.3 as appropriate. All welding procedures and welding
Para 7.5
performance qualification records shall be made available to the Buyer's
Inspector for review.

All welded structural connections shall use weld filler material conforming 12-SAMSS-007
to ANSI/AWS D1.1 Section 3.3 (including Table 3.1) low hydrogen with an Para 4.11, and
A6
electrode strength of 58ksi (400 Mpa) minimum yield strength and 70ksi SAES-M-001
(480 Mpa) tensile strength, unless otherwise required. Para 7.1.13.1

Saudi Aramco: Company General Use


Structural steel pipe shall be limited to seamless or electric-welded,
12-SAMSS-007
A7 straight-seam pipe. Where steel pipes or tubing are used, all open ends
Para 6.1.4
shall be sealed to prevent internal corrosion.

The welding symbols used on plans and shop drawings shall be per the
12-SAMSS-007
A8 American Welding Society (AWS). The field connection symbols shall
Para 6.1.5
distinguish between assembly yard and erection site connections.

All pieces shall be clearly marked with permanent identifying erection


12-SAMSS-007
A9 mark number. Method and location of marking shall be approved by
Para 6.1.14
Buyer.

Inspection of welding shall be performed in accordance with the Structural 12-SAMSS-007


A10
Welding Code, ANSI/AWS D1.1/D1.1M. Para 7.6

All welds shall have 100% visual inspection performed per ANSI/AWS
12-SAMSS-007
A11 D1.1. In addition, any strikes, gouges, and other indications of careless
Para 7.6 a)
workmanship (such as surface porosity) shall be removed by grinding.

All structural strength welding shall be continuous,unless alternate


12-SAMSS-007
A12 procedures are approved by the Chairman of the Onshore Structures
Para 6.2.6.5
Standards Committee.

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 30-Apr-2017 - REV. 2015.03.00 (Standards Cutoff - March 2015) Rev. 2015.03.00 31-Mar-15
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Installation of Wellhead Guard Rails. SAIC-L-2088 30-Apr-17 MECH-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

SAES-M-001
The edges of all tightly contacting surfaces shall be completely seal Para 7.1.13.3
A13
welded. 12-SAMSS-007
Cl 5.2.3.4

Continuous seal-welding shall be used in places that are not self-draining


or where crevice corrosion is likely to occur. If seal-welding is not 12-SAMSS-007
A14
practical, alternative methods of sealing shall be used with the approval of Para 6.2.6.8
the Saudi Aramco Representative.

The minimum fillet weld size is 3/16 inch (5 mm) for structural welds. Seal 12-SAMSS-007
A15
welds may be 1/8 inch (3 mm) minimum fillet weld. Para 6.2.6.4

12-SAMSS-007
A16 Fabricator shall remove all run-off bars and extension tabs.
Para 6.2.6.9

12-SAMSS-007
A17 All re-entrant corners shall be shaped, notched-free, to a radius.
Para 6.1.11

Vent holes shall be provided for piping & tubular assemblies as required
12-SAMSS-007
A18 by ASTM A 385/A385M.The vent holes shall be located in the bottom side
Para 5.2.3.5
to prevent rain water accumulation.

Before surface preparation, the Fabricator shall remove all sharp corners,
12-SAMSS-007
A19 burrs (including bolt hole burrs), weld spatter, slag, weld flux, loose mill
Para 6.1.15
scale and other foreign matter.

Exposed corners, edges, burrs or rough spots on handrails, guards,


12-SAMSS-007
A20 ladders, platforms and stairs, which might cause injury to personnel using
Para 6.1.16
the assembled structure, shall be ground or filed smooth.

General Notes and references on Standard Drawing, AB - 036685,Sht


Standard
A21 001, R-1 should also be followed for fabrication/installation of Wellhead
Drawing.
Barrier.

REMARKS:

REFERENCE DOCUMENTS:
1- Standard Drawing, AB-036685 Sht 001- Rev-1-- Wellhead Guard Barrier.
2- SAES-M-001-- Structural Design Criteria for Non-Building Structures, 19 Dec 2010
3- 12-SAMSS-007 -- Fabrication of Structural and Miscellaneous Steel, 17 May 2011

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 30-Apr-2017 - REV. 2015.03.00 (Standards Cutoff - March 2015) Rev. 2015.03.00 31-Mar-15
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Installation of Wellhead Guard Rails. SAIC-L-2088 30-Apr-17 MECH-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED