ALTERNATIVE FINISHING LAYERS CALCULATION REPORT
BASED ON RFI # 12‐034/AAE/DM/RFI/ST‐218 dated on 2‐Aug.2018 REPLY, REFER TO
(SKETCH.1) FOR R04 FINISHING LAYERS.
Sketch.1
Weight Calculations:‐
1‐ PURLINS
‐ Reference to material data sheet,
Purlins weight/m = 5.75 kg/m
Purlin weight = 5.75 x 2.75 / 2.752 = 2.091 kg/m2
2‐ METAL SHEETS (TIGER Steel)
‐ Reference to material data sheet,
Metal Deck weight (TS 75/300 t=0.7mm) = 8.08 kg/m2
1 | P a g e
3‐ SPRAY FOAM (ECOPUF PE 7504 bf)
‐ Reference to material data sheet the used density is from 30‐35 Kg/m3, by using
average of 32 kg/m3 & slope 1:50.
‐ 10 m (max. span between drain & hump), minimum height of foam at drain 12.5 cm.
‐ At Hump with slope 1:50, maximum height will be (10x1/50) + 12.5 = 32.5 cm.
‐ Average height = (32.5+12.5)/2 = 22.5 cm
Weight per m2 = 0.225 x 1 x 32 = 7.2 kg/m2
(Without deducting the Metal Deck
Corrugation).
‐ Metal Sheet corrugation area = 3x(0.185+0.125)/2 x 0.075 = 0.034875 m2
Weight per m2 = 0.034875 x 32 = 1.116 Kg/m2
SPRAY FOAM WEIGHT /m2 = 7.2 – 1.116 = 6.084 Kg / m2
4‐ WATERPROOFING COAT (MARISEAL 250)
‐ Reference to supplier recommendations & applicator letter, waterproofing will be 2
layers applied by manual roller/brush with consumption rate (1.4 ‐ 2) Kg/m2 both
layers.
Hence average weight for 2 layers /m2 = 1.7 Kg/m2
5‐ SECONDARY WATERPROOFING & FINISHING COAT (MASTERSEAL 588)
‐ Reference to material data sheet the approx. density is 1680 kg/m3.
‐ As per applicator letter, 1 layer to be used for a unit rate of around 1.68 kg/m2.
Hence weight for 1 layer /m2 = 1.68 Kg/m2
6‐ SCENIC PAINTING (Jota shield Topcoat Matt)
‐ Reference to material data sheet & applicator recommendation paints various coats
of average thickness of 0.20 mm, weight per square meter of 0.262 Kg/m2.
Hence weight for 0.20 mm various coats /m2 = 0.262 Kg/m2
7‐ SEALER PROTICTIVE COAT (Jotun Penguard Clear Sealer)
‐ Reference to material data sheet & applicator recommendation, 2 coat of thickness
of 0.10 mm, weight per square meter of 0.33 Kg/m2.
Hence weight for 2 coats of 0.10 mm /m2 = 0.66 Kg/m2
2 | P a g e
TOTAL Weight for R04 system:‐
Layer Weight
(Kg/m2)
PURLINS 2.091
METAL SHEETS 8.08
SPRAY FOAM 6.084
WATERPROOFING COAT 1.7
SECONDARY WATERPROOFING & FINISHING COAT 1.68
SCENIC PAINTING 0.262
SEALER PROTICTIVE COAT 0.66
TOTAL WEIGHT 20.557
Total Weight 20.557 Kg/m2 = 0.20557 KN/ m2 < 0.25 kN/m2 [OK]
THERMAL CALCULATIONS:‐
‐ Reference to IFC specifications Division 07 page # 07 21 00 / 5 point # 2.2.4 the only
information regarding roof R04 the required thermal resistance is 2.64 m2K/W.
‐ Reference to material data sheet of ECOPUF PE 7504 bf the alternative spray foam
under density of 32 Kg/m3, the mentioned K‐Value is 0.022‐0.024 w/m°k.
‐ Spray foam minimum thickness is 12.5 cm including the corrugation of metal sheet,
average minimum thickness = 7.5/2 + 5 = 8.75 cm (where 7.5 is corrugation depth)
Hence, by converting K‐Value to R‐Value (R: thermal resistance)
R = thickness / K,
R= 0.0875/0.024 = 3.645 m2K/W
Spray Foam thermal resistance R= 3.645 m2K/W >2.64 m2K/W [OK]