The Provincial Government of Bulacan has agreed in principle for the relocation of The Correctional
Facility for Women in Mandaluyong to be transferred to the Municipality of Calumpit. The Facility, to be
used exclusively for women shall be used by approximately 1000 inmates, all of which shall be placed
only under minimum security. The Burea of Jail Management and Penology would like a design for
medium security and one that would provide an atmosphere of relaxation and a sende of community for
the municipality. The focus of this design problem is for the student to develop a sculptural sense in the
form of a structure’s façade and the harmony between the natural colors of materials and the produced
product, which will be a modest building as well as a focus on Site Planning together with a sense of
place. The Project shall cover an area as provided for by the lot plan and shall be maximized to
accommodate future expansion. The entire list of space requirements is listed below.
Space Requirements
- Administrative, Service and Maintenance Areas
o Warden’s Offices
Staff of Seven (7)
Business Manager’s Area
o Accounting Department
o Budget
Toilet and Bath
Storage
Lounge and Locker
o Deputy Warden’s Office
Toilet and bath
Storage
Lounge and Locker
Staff of Five (5)
o Information Center
General Library Area and Storage
Librarians Office with Staff
Assistant Librarians Office
Staff of Five (5)
o Counselors Area
Counselor’s Office
Toilet and Bath
Storage
Lounge and Locker
Staff of Ten (10)
o Security Offices with Lockers and Lounge
Guards Quarters for Fifty
Lockers and Facilities for One Hundred Guards
Armory and Storage
o Entrance Facility
Main Entrance and Discharge Facility for Incoming and Outgoing Inmates
- Processing Area
Interview area for Outgoing Inmates
Holding and Detention for Incoming Inmates
Booking Area
Dressing Area with Restrooms
Storage Facility for Personal items and Clothing
Shower and Delousing Area
Medical Facility
Doctors medical Examination Area and Offices
Lockers and Storage
Nurses Lockers and Lounge
Fingerprinting and Records Area
Offices of Staff for Two (2)
Storage
Holding area for Processed Inmates
Other Areas that may be necessary
- Detention Housing
A Maximum of One Hundred Inmates (100) for every Housing Facility
Detention Cells with Open Toilets
o Two inmates per cell maximum
Guards Areas with Locker and Lounge Areas
Communal and Recreation Areas
Communal Shower and Dressing Facilities
Visitation and Conjugal Areas with Observation Areas
Other Areas that may be necessary
- Ecumenical Chapel
PDF Files
◦ All works to be submitted via PDF shall be easily opened with Adobe
Acrobat Reader X version or lower
◦ Any other E-file submission shall be deemed unacceptable
Concept Sheet
You shall create a narrative or explanation on how your form concepts and abstract came about.
Please use 1500 words at most. It would be helpful if you can include a one-line summary of this
explanation. This shall act as you Design concept.
You shall also include a list of six to nine design considerations that you believe should be part of the
variables affecting your design in relation to your design concept. Kindly explain them.
Drawing Support
E-file submission
PDF Files
◦ All works to be submitted via PDF shall be easily opened with Adobe Acrobat Reader
X version or lower
◦ Any other E-file submission shall be deemed unacceptable
Schedule of Submittals
All previously submitted drawings from March 3 to March 22 shall be submitted as part
of the final output on March 31, 2020 showing progress of your work and with