Professional Documents
Culture Documents
ADIBA KHAN
B.ARCH 5TH YEAR
ROLL NO. 1682381002
DATA PRESENTATION (ANTHROPOMETRIC DATA)
INTRODUCTION
Wrinkle free Steam irons 8.18 LABS- APPAREL DESIGN DEPARTMENT
•In India, the readymade garment industry had its
beginning during the first half of the 20th century and machine PATTERN MAKING LAB-
has witnessed impressive growth during the last four SEWING MACHINE (960X540X820)
decades. It is reported to be the second highest Fusing machine Electric boiler CUTTING TABLE (1500X900X900)
contributor to india’s export basket, after „games and WHITE BOARD & SOFT BOARD FOR
jewellry‟. There are around 70,000garment DISPLAY STORAGE SPACE
Needle/ metal Form finishers, top
manufacturing units in the country providing GARMENT CONSTRUCTION LAB
employment to more than detector jet & rotor cabinets WEAVING MACHINE (700X600X820)
3 million persons. The unit would have the following Vaccum tables JACQUARD ROOM (1300X1200X1500)
Clot inspection
facilities:- CHARKHA (900X300X500)
•Manufacturing unit machine
•Design centre 8.17 LABS- TEXTILE DESIGN DEPARTMENT
Auto cleaning and Embroidery machines
Quality control lab DYEING & PRINTING LAB
thread sucking
•Ware house The unit would employ the following key PRINTING MACHINE(2500X1500X760)
machinery: - machine CYLINDRICAL MACHINE FOR DYEING
(3000X2500)
FUNCTION OF A GARMENT Cutting machine Quilting machines WEAVING LAB
MANUFACTURING UNIT WEAVING MACHINE (700X600X820)
Intermediate finishing Dry cleaning JACQUARD ROOM (1300X1200X1500)
It is a complete network of functions like
•Material storage. and steam machine CHARKHA (900X300X500)
•Component manufacture. process
•Assembly. 8.19 LABS- FASHION DESIGN DEPARTMENTPATTERN
•Inter process storage. Industrial sewing Cad software MAKING LAB-
•Packaging. SEWING MACHINE (960X540)/STUDENT
•Dispatch & transport interface , all of which must machine INTERLOCKING MACHINE (1100X600)
work. IRONING MACHINE (1300X700X750)
SMALL TABLE (1700X300X750)
STEAM IRON TABLE (1500X820X820)
1.OFFICES FORACADEMIC STAFF STEAM BOILER (600X450)
MACHINE LAB
Professor 20- 24 sq. Mt. SMALL TABLE (1700XX300X750)
Lecturer 15 sq. Mt. MACHINE (800X500)
Assistants 20 sq. Mt
Typist 15 sq. Mt.
SEMINAR ROOMS
Seminars halls usually have 20,40,60 seats space
required for per student 1.90 to 2m
ANGLE:
• the blackboard should be at least 30 degrees and preferably more
than 45 degrees.
DRAWING STUDIO
• Space required 3.5 to 4.5 sq. Mt. Per student.
• 1/3 to ¼ of floor space large windows, if necessary
additional top lights.
• Natural lighting is preferable and so the north facing
studio is best to receive even day light.
Submitted By ADIBAKHAN
Library Study Roll No. 1682381002
Accurate Institute Of Arch. & Planning
ADMINISTRATION LIBRARY
Administration is the area to run the whole
used by all the students, teachers and
activities in the vicinity. It is to provide
offices for executive directors, deputy outsiders, from industry and for research
director, dean and registrar etc. and for preference work.
Along with spaces for their pa’s and waiting Is provided for issue books, catalogues stacks
area.
for reference section, periodical section,
1.The administrative assistants
and other clerical staff are to be audiovisual section, viewing facilities
provided with an open plan discussion areas photographic facilities etc.
office. Also the admission office Enquiry, issue and catalogue facilities are to be
is to be provided which look
close to the entrance of the library for ease
after the admission related
activities. A board room for the of operation and control.
conference purpose is to be Also, material wing consists of textiles,
provided with all aud Visual costumes and accessories.
facilities.
• .
• For auditorium with more than 800 fixed seats at spectator
STAGE
level, two wheelchair spaces shall be provided for every There are three stage forms:- full stage, small stage and
400 fixed seats and any part thereof. (For example, at least set areas. Full stage
six wheelchair spaces shall be provided if there are 900 • More than 100 sq. Mt. Of stage area
fixed seats.) • Stage ceiling more than 1m above top of proscenium
• The spaces shall be grouped in pairs (not less than two) arch.
and also not separated from the seats for other audiences. • The stage is separated from the auditorium by
• Each wheelchair space shall have unobstructed line of means of an iron safety curtain in the event of
vision to the stage areas at which the relevant activity emergency. Small stage
takes place, and be of minimum size of 800 mm x 1300 • Area not more than 100 sq. Mt, no stage extension,
mm, with the side of 800 mm facing towards the stage stage ceiling not more than 1 m above top of
podium or screen. proscenium and this stage doesn't require an iron
• The minimum width of the passage leading to a wheelchair safety curtain. Set areas Raised acting area without
space from an accessible entrance of the auditorium shall any ceiling projection.
not be less than 1500 mm. Readily removable seats can be
installed in wheelchair spaces when the spaces are not
occupied by wheelchair users.
Submitted By ADIBAKHAN
Page No. 5 Library Study Roll No. 1682381002
Accurate Institute Of Arch. & Planning
STANDAR - OUTDOOR PICH