ARI-myValve® - Version 3.

14
ARI-Excess pressure regulator PREDEX-Calculation
Project data
Project-No. project
Description Regulating Valve
Customer John Cockerill
Contact Luc Malpas
Prepared by marc.de.wilde
Order
TAG-No. 328-PCV-802--
Note Calcul Predex
Media and process data Value Unit
Media selection Saturated steam

Temperature 186.1 °C
Specific.volume[υ] 0.17 m³/kg
Isentropic exponent [κ] 1.13

Upstream pressure [p1] 10.5 bar(g)


Outlet pressure [p2] 2.0 bar(g)
Mass flow [W] 12.0 t/h

Result data Value Unit


Kv-value 91.03
Cv-value 106.2
Stroke position 47.75 %
Outlet velocity 122.5 m/s
Mach number 0.2606
Sound pressure level in 1m 90.35 dB(A)
Insulation 82.35 dB(A)
Sound pressure calculation acc. to DIN EN 60534-8-3 2001.
Attention! Flow limitation/choked flow!
Sound pressure level above 85 dB(A)!
Valve form factor 0.46
Valve factor XT 0.72
Correction factor for Kvs 1.15

Pipe data Nominal Nominal Di[mm] s[mm] Speed Unit


Pipe D1 250 PN 40 258.8 7.1 10.77 m/s
Pipe D2 350 PN 40 338.0 8.8 24.13 m/s
Product data
Productkey 30102400193
Article code 357050150G1
Type ARI- PREDEX 35705
Designation Excess pressure regulator, straight through with diaphragm actuator UDA 40
Material 1.0619+N
Nominal pressure PN 40
Connection flange
Nominal diameter DN150
Kvs 280.0[m³/h]
Stem sealing Stainless steel bellow
Plug Metal plug with flow devider
Set value-range 8 - 16 bar / 116 - 232 psig
Material-membrane EPDM
At selection of the valve, observe following factors:
Material resistance, limits for nominal diameter and temperature

2020/05/27 ARI-Armaturen Albert Richter GmbH & Co.KG, 33756 Schloß Holte-Stukenbrock,Tel:+49(0)5207/994-0: Fax:+49(0)5207 994-297
1 / 4 Web : https://www.ari-armaturen.com Email : myvalve@ari-armaturen.com
project-328-PCV-802---calc-en.pdf
ARI-myValve® - Version 3.14
ARI-Excess pressure regulator PREDEX-Calculation

2020/05/27 ARI-Armaturen Albert Richter GmbH & Co.KG, 33756 Schloß Holte-Stukenbrock,Tel:+49(0)5207/994-0: Fax:+49(0)5207 994-297
2 / 4 Web : https://www.ari-armaturen.com Email : myvalve@ari-armaturen.com
project-328-PCV-802---calc-en.pdf
ARI-myValve® - Version 3.14
ARI-Excess pressure regulator PREDEX-Calculation

Project-No. project
Description Regulating Valve
Customer John Cockerill
Contact Luc Malpas
Prepared by marc.de.wilde
Order
TAG-No. 328-PCV-802--
Note Calcul Predex

Product data
Productkey 30102400193
Article code 357050150G1
Type ARI- PREDEX 35705
Designation Excess pressure regulator, straight
through with diaphragm actuator UDA
40
Material 1.0619+N
Nominal pressure PN 40
Connection flange
Nominal diameter DN150
Kvs 280.0[m³/h]
Stem sealing Stainless steel bellow
Plug Metal plug with flow devider
Set value-range 8 - 16 bar / 116 - 232 psig
Material-membrane EPDM
Dimension in mm
DN H L øD øK nxød
DN150 670 480 300 250 8 x 26
POS Designation Material Sp.p.
1 Body GP240GH+N, 1.0619+N
2 Screwed seat ring X20Cr13+QT, 1.4021+QT *
3 Studs 25CrMo4, 1.7218
4 Gasket GRAPHIT *
5 Bush housing EN-JS1049 / 1.4021+QT
6 Gasket GRAPHIT *
8 Balanced-bellow-unit X20Cr13+QT, 1.4021+QT *
9 Plug X20Cr13+QT, 1.4021+QT *
10 Washer A4 *
11 Head X6CrNiTi18-10, 1.4541 *
12 Bonnet closed EN-GJS-400-18U-LT, EN-JS1049
14 Hexagon nut C35E-A2F, 1.1181-A2F
15 Gasket GRAPHIT *
16 Sealing-bellow-unit 1.4571 / 1.4301 *
17 Adjusting plate EN-GJS-400-18U-LT, EN-JS1049
18 Head EN-GJS-400-15, EN-JS1030
19 Screw joint 11SMn30+C, 1.0715+C
20 Thread pin 45H-A2F
21 Guide bush PTFE25%C
22 Guide coupling X20Cr13+QT, 1.4021+QT
23 Cylindrical balls 102 Cr 6, 1.2067
24 Securing wire X10CrNi18-8, 1.4310
25 Spring 51CrV4, 1.8159 *
26 Spring plate S235JR, 1.0037
27 Axial bearing
28 Pressure plate 11SMn30+C, 1.0715+C
29 Parallel pin St
30 Groove nut 5.8-A2F
31 Pneumatic Actuator UDA *
32 Thread pin 45H-A2F
33 Set value bonnet GX5CrNiMo19-11-2, 1.4408
2020/05/27 ARI-Armaturen Albert Richter GmbH & Co.KG, 33756 Schloß Holte-Stukenbrock,Tel:+49(0)5207/994-0: Fax:+49(0)5207 994-297
3 / 4 Web : https://www.ari-armaturen.com Email : myvalve@ari-armaturen.com
project-328-PCV-802---calc-en.pdf
ARI-myValve® - Version 3.14
ARI-Excess pressure regulator PREDEX-Calculation
34 Coupling X20Cr13+QT, 1.4021+QT *
35 Securing wire X39CrMo17-1+QT, 1.4122+QT *
40 Flow devider X20Cr13+QT, 1.4021+QT

2020/05/27 ARI-Armaturen Albert Richter GmbH & Co.KG, 33756 Schloß Holte-Stukenbrock,Tel:+49(0)5207/994-0: Fax:+49(0)5207 994-297
4 / 4 Web : https://www.ari-armaturen.com Email : myvalve@ari-armaturen.com