210 PZ2 Self-contained Photoelectric Sensors Self-contained Photoelectric Sensors PZ2 211

Greatly improved serviceability Lineup Fibreoptic

Self-contained
Mounting the sensor body and routing the cable can be performed
Type Appearance Detecting distance Model Output Photoelectric
independently, reducing time and labour.
If replacing the sensor body with a new one because of damage, or PZ2-51 NPN

Photoelectric Sensors
Thrubeam 7m Proximity
if replacing the sensor body with a different model due to changes PZ2-51P PNP
in specifications, you need only to replace the sensor body.
PZ2-61 NPN Area Sensor

PZ2 Series
Retro-refl ective 2.5 m
PZ2-61P PNP
Pressure
PZ2-41 NPN
Long-range 60 cm Multi Function
PZ2-41P PNP
Diffuse-
refl ective
Refer to P.837 for a list of products PZ2-42 NPN High Precision
complying with EU Directives. Short-range 10 cm
PZ2-42P PNP
PLC/Touch Panel

Static
Options Elimination

Vision System
Support Tools Reflector
S-P01 Free adjuster S-P12 Protective cover Reflector Reflector Reflector PRO
Laser Marker
Freely-adjustable height and Protective cover with R-2 R-3 R-5* reflection
IP67 rated, waterproof construction angle. mounting bracket. (accessory (optional) (optional) tape
Barcode
Both vertical and horizontal Thickness: 3.0 mm for PZ2-61) OP-96436 (optional)
PZ2 sensors use a detachable cable and OP-95388 OP-96629
mountings are available. (Stainless steel). Microscope
IP67 rated construction for peace-of-mind 47 11.6
in sites where equipment may get wet. 31
40

47 31
34 30

PHOTOELECTRIC
SELECTION GUIDE
PZ2-61(P) PZ2-61(P) PZ2-61(P) PZ2-61(P)
P.R.O.* function provides stable detection of Detecting Detecting Detecting Detecting CMOS LASER
distance distance distance distance GV
mirrored surfaces (PZ2-61) when using when using when using when using
PZ2-61 (P): PZ2-61 (P): PZ2-61 (P): PZ2-61 (P): COMPACT LASER
* Polarised Reflection Optics LV-S/H
2.5 m 1.7 m 0.7 m 0.2 to 0.8 m
Reflector
Transmitted light waves are horizontal.
The polarisation of the RGB COLOUR
* The order code for R-5 is R-5. The order code for other reflectors
horizontal light emitted by CZ-V20
is the OP number.
the transmitter is CZ
interrupted by the
reflector, and it returns to FLUORESCENCE
the receiver as scattered A-3 attachment kit (optional) specially designed for PZ2-51 and -51P thrubeam models DETECTION UV
When light hits the reflector, its polarisation is CZ-H52
interrupted and it is reflected in all directions. light. Slit plate only Slit plate and polarising filter
LUSTRE
Slit width Detecting distance Target size Slit width Detecting distance Target size
Reflector
Transmitted light waves are horizontal.
In the case of mirrored DETECTION
surfaces, the horizontal 0.5 mm 500 mm 0.5 x 5 mm 0.5 mm 200 mm 0.5 x 5 mm CZ-H72
light is not received 1 mm 800 mm 1 x 5 mm 1 mm 400 mm 1 x 5 mm HEAVY-DUTY
because it is reflected in PX
2 mm 1500 mm 2 x 5 mm 2 mm 700 mm 2 x 5 mm
the same state when it hits
Polarisation remains unchanged for mirrored the detected object. SEPARATE AMP.
surfaces. PS

SELF-CONTAINED
PZ-G
PZ-V/M
PZ2
PZ2-62
Features PZ-101
❙ Excellent mirror surface detection
AMP-IN-CABLE
❙ IP67 rated waterproof PQ
❙ Sensors can operate side-by-side
MULTI-VOLTAGE
PW

Expert Engineering Sites PASSAGE


PG
www.sensorcentral.com
An on-line guide of
automation knowledge
and techniques

CAD DATA Download:


210 TECHNICAL GUIDE: P.754 www.keyence.com.sg/CADG www.keyence.com.sg 211
212 PZ2 Self-contained Photoelectric Sensors Self-contained Photoelectric Sensors PZ2 213
Specifications Dimensions Unit: mm
Fibreoptic
PHOTOELECTRIC SENSORS
PZ2-41(P)/42(P)/61(P) PZ2-51(P) PZ2 (with mounting bracket)
Retro-reflective Diffuse-reflective Photoelectric
Type Thrubeam Operation mode Sensitivity Operation mode selector switch (Receiver) 3 30
Polarised Long-range Short-range selector switch adjustment trimmer Sensitivity adjustment trimmer 9 7 7
(Transmitter) Proximity
NPN PZ2-51 PZ2-61 PZ2-41 PZ2-42 5 14.5
Model 4.4 Attachment 20
PNP PZ2-51P PZ2-61P PZ2-41P PZ2-42P
mounting trimmer Indicator 14.5 Area Sensor
Indicator 6 6 3.5 11
6 6 3.5 8.2
11 11
0.6 Pressure
9.5 2.5 2.5 20 6
20 9.5
Centre of 2-M3 x 16 Indicator
emitted light Centre of light Multi Function
Appearance
4 30 23 30 23
4 High Precision
Centre of 14.5 14.5 23
received 39
light 3 3
ø3.5, 3-core x 0.18 mm2
2 x ø3.2 2 x ø3.2 21 PLC/Touch Panel
3 mounting ø3.5, 3-core x 0.18 mm2 3 mounting
600 mm (200 x 200 mm 100 mm (100 x 100 mm Cable length: 2 m hole Cable length: 2 m hole 6.5 9.5
Detecting distance 7,000 mm 2,500 mm (with R-2) Static
white mat paper) white mat paper)
Opaque materials Opaque materials Elimination
Detectable object Transparent and opaque materials
(8 x 8 mm min.) (30 x 30 mm min.)
Vision System
Hysteresis — 20% max. of detecting distance PZ2-51(P)
When attachment (A-3) is attached. Mounting bracket (accessory) Flat nut (accessory)
Response time 1.5 ms max. 1 ms max. (2 ms in alternate frequency mode 1.) Laser Marker
3.5
Light source Visible red LED 9
3.5
5
14.5 22xxM3
M3
23 29
23 29
Barcode
screw
screw
Sensitivity adjustment 1-turn trimmer (240°) *Supplied
*Suppliedscrews:
screws:
11 6.8
4 7 7 9 M3
M3x x16:
16:2 2
Operation mode LIGHT-ON/DARK-ON (switch-selectable) D 2 t=1.2
Material:
Microscope
Attachment Material:Stainless
Stainless
30 66 t=1.6
t=1.6 steel
steel
Indicators Output and power 2.: Red LED, Stable operation: Green LED
23 Material:
Material:Stainless
Stainlesssteel
steel
3 Two
Twonuts
nutsshown
shownabove
abovearearesupplied
supplied
Control output NPN or PNP: 100 mA (40 V) max., Residual voltage: 1 V max. for
forthe
thethrubeam
thrubeamtype.
type.
5 31 3.2 3
Protection circuit Reversed polarity, overcurrent protection, surge absorber 3.2
D
15.5
36 23 Connector
PHOTOELECTRIC 0.5 PHOTOELECTRIC
Power supply 12 to 24 VDC ±10% 55 (1) 10
SELECTION GUIDE 1.0 0.9
0.9 (1) 10 SELECTION GUIDE
2.0 1
T: 20 mA max. 9.5
Current consumption 35 mA max.
CMOS LASER R: 25 mA max. 16.4
16.4 Lock
Lock CMOS LASER
Material: Stainless steel
GV Enclosure rating IP67 GV
Ambient light Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.
COMPACT LASER COMPACT LASER
LV-S/H Ambient temperature -20 to +55°C, No freezing LV-S/H
Reflector R-2 (accessory for PZ2-61) Reflector R-3 (optional)
RGB COLOUR Relative humidity 35 to 85%, No condensation RGB COLOUR
CZ-V20 (OP-95388) (OP-96436) R-5 14 11.5
CZ-V20
11.6 2.6 2-M3
Housing Glass-fibre reinforced plastic
CZ CZ
47 31
Weight (including 2-m connector Transmitter/receiver:
Approx. 50 g
FLUORESCENCE cable) Approx. 50 g each FLUORESCENCE
DETECTION UV 36 34 25.4 DETECTION UV
1. The different-frequency type has “D” at the end of the model No. PZ-41D(P)/42D(P)/61D only. 25.6 17.5
CZ-H52 2. The power indicator is equipped with the PZ2-51 only. CZ-H52
31 35
47 42
51.2 3
61
LUSTRE 21 LUSTRE
DETECTION DETECTION
30.4
CZ-H72 PRO reflection tape 40 CZ-H72
Input/Output Circuits 15 2
x (optional)
ø3 3.5
HEAVY-DUTY .6 HEAVY-DUTY
25 OP-96629 30
PX NPN 30
2
x
ø4 3.5 35
5.5
PX
.5 8
PZ2-61/41/42/51 (Receiver) 40
5.5
t=0.7
SEPARATE AMP. 51.2 SEPARATE AMP.
8
PS PS
Brown
SELF-CONTAINED S-P01 S-P01 Head SELF-CONTAINED
protection circuit

PZ-G PZ-G
Load

11.8 A 21 23 27
Short-circuit

PZ-V/M B PZ-V/M
circuit

Black
Main

12 to 24 VDC 10 5 x M3 Supplied
PZ2 17.3 screws 21 PZ2

°
45
21
PZ2-62 PZ2-62
PZ-101 6.5 15.5 PZ-101
Blue 24.5

45°
23

AMP-IN-CABLE 14.5 AMP-IN-CABLE


PQ ø10 PQ
PNP
149 C
MULTI-VOLTAGE PZ2-61P/41P/42P/51P (Receiver) PZ2-51/51P (Transmitter) 216 MULTI-VOLTAGE
PW PW
S-P12 0.4
34

Brown Brown
PASSAGE PASSAGE
PG PG
protection circuit

12.5 36
Short-circuit

5
circuit

Black Pink
circuit

47
Main

Main

12 to 24 VDC 12 to 24 VDC D
(Stop input light emission) 26 6.8 8.9
30
Load

13 43
32 4 x ø7
Blue Blue mounting
46 hole
Supplied
screw 5.5 Supplied
31 23 plate nut
A B C D
13 32 27 17.3 162 40.5 46
24.5

t=3.0

CAD DATA Download:


212 TECHNICAL GUIDE: P.754 CAD DATA Download: www.keyence.com.sg/CADG TECHNICAL GUIDE: P.754 www.keyence.com.sg/CADG www.keyence.com.sg 213

You might also like