You are on page 1of 4

]AMMU AND KASHMIR POWER DEVELOPMENT

CORPORATION LIMITED
OTFICE OF THE CEOLOCISI GEOLOGICAL DIVISION,J MMU.
480-F Nitcolane,TalabTillo, Jammu
Phone/Fax: 0 I 9 1 -2502885
E-mail : - geologistj mu @gmail. com

The Executive Engineer No: GD/JKSPDCIII $o5-o f


CCD-I, Kirthai Date: )B,,il" )1q
Gulabgarh (Paddar)

Sub: Determination of Bearing Capacity and Other Laboratory Test (UCS) at Gulabgarh
(Paddar).

Ref: 1. Your office letter No: HEP/I(-ll9l-92, Dated: 27-9-2019.


2. Chief Engineer Kirthai letter No: CE/Ifirthai/I{EPs/148-51, Dated: 27-06-2019.
3. Your office letter No: HEP/I(-A68-69, Dated: 18-6-2019.

Sir,
Kindly find enclosed herewith the test reports of three number of Plate Load Tests
conducted by Research Officer, Jammu (HRS/MTL) Design Inspection and Quality Control
(DIQC) Jammu and Kashmir Government at Gulabgarh (Paddar), Kisthwar on our request to
determine the soil bearing capacity of land to be developed for infrastructure of Kirthai HEPs at
Gulabgarh.

As intimated by the Research Officer, Jammu (HRS/MTL) DIQC Jammu, the results of the
core samples for UCS shall be submitted later on as it require some time for the tests.

This is for your information and necessary action please.

Yours faithfull

Divisional Geologist (Engg.)


Geological Division
JKPDC, Jammu Encl: 3 (Three)

Copy To:
1. Executive Director (Civil), JKPDC for kind information please.
2. Chief Engineer, Kirthai HEPs for information please.
3. General Manager (Civil) for information please.
4. P.A to M.D for information to Managing Director JKPDC.
Government of Jammu & Kashmir
Office of the Research Officer - Jammu (HRS/MTL)
Design Inspection & Quality Control (DIQC) - Jammu (J&K)
1T* PI*.'fJIltl I*".'*.T -
ca na I ra m m u

Description of Test - Plate Load Test for determination of Soil Bearing Capacity.
Reference: - Divisional Geologist (Engg.) Geological Division JKSPDC, Jammu vide his Letter No.
GD/JKSPDCru/192 Dated : 24.07 .20L9.
Testing Charges: - Received Rs. 89,100/- (Rs. Eighty Nine Thousand & One Hundred only) on account of
testing charges vide G.R. Nos. A- 2322569 Dated 18.10.2019 (03 PLT + UCS of Core Rock
sample).
Report: As desired by Divisional Geologist (Engg.) Geological Division JKSPDC, Jammu vide his letter
under reference, First Plate Load Test was conducted at Gulabgarh Kishtwar for
construction Office Compldx for Kirthai HEP. The site was identified by the concerned
department, where they have excavated trench of 4'-0" depth for conducting of safe Soil
Bearing Capacity test. The moisture content 6,380/o was determined after conducting
the test. At 15 tons, Loading Frame got lifted. The test data is as under:-
Safe Soil Bearing
Capacity
Size of Test Classification of Soil (adopting factor of
S. No. Regd. No. Date of Test Strata
Plate Used safeW as 3)
kq/cm2 t/m2
Gravels =70.20o/o
1. 263119-20 02.L1.2019 30cmx30cm Sand= 20.46% & 1.48 14.8
Silt & Clay =$.34o/o

Load Intensity Cumulative


(in kg/cmzl Settlement (in cms.)
1.1 0.01

2.2 0.01

3.3 0.01

4.4 0.02

5.6 0.04

6.7 0.07

7.8 0.11

8.9 0.15

10.0 0.20

11.1 0.25

L2.2 0.30

13.3 0.34

L4.4 0.37

15.6 0.41

I n
W g/*rLdvv\ d'
MA
, ill-j-sstfsection
Sdrintlfic Asstt.
6il section
Jr. Res. Asstt.
Soil Section ffr{,
Lf MTL-Jammu MTL - Jammu MTL - Jammu B!,-'

No: - RO/HRS-MTLIJMU lTR/zOLgI q qS- q6 Dated:


I q.11. 2o I g
Copy to the: -
1, Chief Engineer: Design Inspection & Quality Control Deptt. (J&K) - Jammu, for kind information.
llT ? Divisional Geologist (Engg.) Geological Division JKSPDC, Jammu.
Offirr: Order File
Government of Jammu & Kashmir
Office of the Research Officer - Jammu (HRS/MTL)
Design Inspection & euatity Controt (DIQC) - Jammu (faX;
ca nar - ra m m u
lT*.'If.rxl{ II"ffJ
Description of Test - Plate Load Test for determination of Soil Bearing Capacity.
Reference: - Divisional Geologist (Engg.) Geological Division JKSPDC, Jammu vide his Letter No.
GD[KSPDC[/192 Dated: 24.07.20L9.
Testing Charges: - Received Rs. 89,100/- (Rs. Eighty Nine Thousand & One Hundred only) on account of
testing charges vide G.R. Nos. A- 2322569 Dated 18.10.2019 (03 pLT + U-CS of Core Rock
sample).
Report: As desired by Divisional Geologist (Engg.) Geological Division JKSpDc, Jammu vide
his letter
under reference, Second Plate Load Test was conduc[ed at Gulabgarh Kishtwar for
construction Office Complek for Kirthai HEP. The site was identified by the concerned
department where they have excavated trench of 4'-0" depth for conducting of safe Soil
Bearing Capacity test. The moisture content 7,53o/o was determined after conducting
the test. At 14 tons, Loading Frame got lifted. The test data is as under:-

Safe Soil Bearing


Size of Test Classification of Soil Capacity
S. No. Regd. No. Date of Test (adopting factor of
Plate Used Strata
safety as 3)
kglcmz tlmz
Gravels=69 .4Lo/o
1. 264/19-20 04.LL.20L9 30cmx30cm Sand= 19.57olo & 1.853 18.53
Silt & CIay = 11 .02o/o

Load Intensity Cumulative


(in ks lcmz) lgltlement (in cms.)
1.1 0.03
2.2 0.05
3.3 0.07
4.4 0.10
5.6 0.13
6.7 0.L7
7.8 0.30
8.9 0.45
10.0 0.57
11. 1 0.64
L2.2 0.68
13.3 0.70
L4.4 0.70

ic Asstt.
Sfuna*L
Jr. Res. Asstt.
il Section Soil Section
MTL - Jammu MTL - Jammu MTL - Jammu

No: - RO/HRS-MTL/JMU lTRl 2OL9 I


Qqq-*scrb Dated:
lq'll.r"rg
Copy to the: -
1. Chief Engineer: Design Inspection & Quality Control Deptt. (J&K) Jammu, for kind
information.
l-r 3.
Divisional Geologist (Engg.) Geological Division JKSPDC, Jammu.
Office Order File.
-Government of Jammu & Kashmir
Office of the Research Officer - Jammu (HRS/MTL)
Design Inspection & Quality Control (DIQC) - Jammu (J&K)
ca na I - rammu
1'."* :If.nJIlI I.1n.T
Description of Test - Plate Load Test for determination of Soil Bearing Capacity'
Divisional Geologist (Engg.) Geological Division JKSPDC, Jammu vide his Letter
No'
Reference: -
GD/JKSPDC/J/192 Dated t 24,07 .20L9.
of
Testing Charges: - Received Rs. 89,100/- (Rs. Eighty Nine Thousand & one Hundred only) on account
t*ting charges vide G.R. Nos. A- 2322569 Dated 18.10.2019 (03 PLT + UCS of Core Rock
sample),
As desired by Divisional Geologist (Engg.) Geological Division JKSPDC, Jammu
vide his letter
Report:
under reference, Third Plaie Load Test was conducted at Gulabgarh Kishtwar for
construction Office Complex for Kirthai HEP. The site was identified by the concerned
Oepa*ment, where they have excavated trench of 4'-0" depth for conducting of safe Soil
Bearing Capacity test. The moisture content 3.260/o was determined after conducting
ttre test. Al15 tons, Loading Frame got lifted. The test data is as under:-
Safe Soil Bearing
Capacity
Size of Test Classification of Soil (adopting factor of
S. No. Regd. No. Date of Test Plate Used Strata safety as 3)
kg/cmz t/mz
Gravels =76.54o/o
06.11.2019 30cmx30cm Sand= 17.98o/o & 1.48 t4.B
1. 26slL9-20
Silt & Ctay =5.48olo

Load Intensity Cumulative


(in kg/cmz) Settlement (in cms.)
1,1 0.01

2.2 0.02

3.3 0.03

4.4 0.04

5.6 0,06

6.7 0.09

7.8 0.11

8.9 0.12

10"0 0.16

t 1.1 0.20

t2.2 0.23

13.3 0.25

L4.4 0.28

15.6 0.31

a"ftrn"+n
Jr. Res, Asstt.
Soil Section
MTL - Jammu MTL - Jammu

No: - RO/HRS-MTLIJMU lTR.lzOLgI 7 qV-98 Dated:


/Q.ll- 4t1
Copy to the: -
1. Chief Engineer: Design Inspection & Quality Control Deptt. (J&K) - Jammu, for kind
information.
llt 2
Divisional Geologist (Engg.) Geological Division JKSPDC, Jammu'
Affi^a ArAar trilo