You are on page 1of 98

0 1 2 3 4 5 6 7 8 9

National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar

TITLE : WINCH DATASPLIT C

DRAWING No. : ES6931033765

REGULATIONS : ATEX

RISK CATEGORY : Cat 3G, IIB, T3

AREA CODE : Zone 2

DESIGN TEMPERATURE : -20°C / +40°C

MAIN SUPPLY : 115/230V 50/60Hz

NOTE : Note.
G.Martina
A H.Tuytelaars M. KRAUS
11-01-2011

H.Tuytelaars
B -- G.Martina M. KRAUS RELEASED
Total number of pages : 98 12-09-2011

REV. ECO DRAWN CHECKED APPROVED REMARK

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = GEN + - 1
0 1 2 3 4 5 6 7 8 9

Higher Level Assignment- / Location Designation overview


CODE Higher Level Assignment DESCRIPTION Higher Level Assignment CODE Location Designation DESCRIPTION Location Designation

=CAB Cabin +ECP5 ECP5 = WNCH 24V IFM SD/DD ATX 8501035865/1

=GEN General +ECP20 ECP20 = BOX EEX-E 300X200X150mm WITH 3 COLOUR LIGHTS A1100659

=INF Information +EJB13 EJB 100x100x60 SS ATX ASSY MEASUREHEAD 8501035839/1 EJB13 MEASUREHEAD ATX

=WNCH Winch

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Higher level assignment- / location designation overview = GEN + - 2
0 1 2 3 4 5 6 7 8 9

Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR

=GEN+/1 Frontpage 12.Sep.2011 tuytelaarsh

=GEN+/2 Higher level assignment- / location designation overview 12.Sep.2011 tuytelaarsh

=GEN+/3 Page overview 12.Sep.2011 tuytelaarsh

=GEN+/3.a Page overview 12.Sep.2011 tuytelaarsh

=GEN+/3.b Page overview 12.Sep.2011 tuytelaarsh

=WNCH+/1 Frontpage 26.Aug.2011 MartinaG2

=WNCH+/21 Block Diagram 25.Aug.2011 MartinaG2

=WNCH+/25 Intrinsically Safe Circuits 14.Jan.2011 MartinaG2

=WNCH+/31 Connectors 15.Aug.2011 tuytelaarsh

=WNCH+/32 Electric symbol overview 14.Jan.2011 MartinaG2

=WNCH+/60 Slipring 25.Aug.2011 MartinaG2

=WNCH+/210 Operator Panel 25.Aug.2011 tuytelaarsh

=WNCH+/1400 Cable overview : 12.Sep.2011 tuytelaarsh

=WNCH+/1401 Cable overview : 12.Sep.2011 tuytelaarsh

=WNCH+/1402 Cable overview : 12.Sep.2011 tuytelaarsh

=WNCH+/1500 Bill of materials electric 12.Sep.2011 tuytelaarsh

=WNCH+/1501 Bill of materials electric 12.Sep.2011 tuytelaarsh

=WNCH+/2500 Hazardous area schedule 12.Sep.2011 tuytelaarsh

=WNCH+/2501 Hazardous area schedule 12.Sep.2011 tuytelaarsh

=WNCH+ECP5/1 Frontpage 11.Aug.2011 tuytelaarsh

=WNCH+ECP5/30 Terminal Strips & Connectors 25.Aug.2011 tuytelaarsh

=WNCH+ECP5/102 Cabin & Winch Lights 12.Sep.2011 tuytelaarsh

=WNCH+ECP5/300 Safety controller EX 24.Aug.2011 tuytelaarsh

=WNCH+ECP5/301 Safety controller 24.Feb.2011 MartinaG2

=WNCH+ECP5/302 Safety controller 24.Aug.2011 tuytelaarsh

=WNCH+ECP5/303 Safety controller 25.Aug.2011 tuytelaarsh

=WNCH+ECP5/304 Safety controller 25.Aug.2011 tuytelaarsh

=WNCH+ECP5/305 Safety controller 11.Aug.2011 tuytelaarsh

=WNCH+ECP5/1100 Terminalconnectionlist : =WNCH+ECP5#-X51 12.Sep.2011 tuytelaarsh

=WNCH+ECP5/1101 Terminalconnectionlist : =WNCH+ECP5#-X52 12.Sep.2011 tuytelaarsh

=WNCH+ECP5/1102 Terminalconnectionlist : =WNCH+ECP5#-X52 12.Sep.2011 tuytelaarsh

=WNCH+ECP5/1103 Terminalconnectionlist : =WNCH+ECP5#-X54 12.Sep.2011 tuytelaarsh

=WNCH+ECP5/1104 Terminalconnectionlist : =WNCH+ECP5#-X54 12.Sep.2011 tuytelaarsh

=WNCH+ECP5/1105 Terminalconnectionlist : =WNCH+ECP5#-X54 12.Sep.2011 tuytelaarsh

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.a

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3
0 1 2 3 4 5 6 7 8 9

Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR

=WNCH+ECP5/1500 Bill of materials electric 12.Sep.2011 tuytelaarsh

=WNCH+ECP5/2500 Hazardous area schedule 12.Sep.2011 tuytelaarsh

=WNCH+ECP20/1 Frontpage 11.Aug.2011 tuytelaarsh

=WNCH+ECP20/30 Terminal Strips & Connectors 15.Aug.2011 tuytelaarsh

=WNCH+ECP20/250 WHM System 25.Aug.2011 MartinaG2

=WNCH+ECP20/1100 Terminalconnectionlist : =WNCH+ECP20#-X202 12.Sep.2011 tuytelaarsh

=WNCH+ECP20/1101 Terminalconnectionlist : =WNCH+ECP20#-X204 12.Sep.2011 tuytelaarsh

=WNCH+ECP20/1500 Bill of materials electric 12.Sep.2011 tuytelaarsh

=WNCH+ECP20/2500 Hazardous area schedule 12.Sep.2011 tuytelaarsh

=WNCH+EJB13/1 Frontpage 11.Aug.2011 tuytelaarsh

=WNCH+EJB13/30 Terminal Strips & Connectors 15.Aug.2011 tuytelaarsh

=WNCH+EJB13/200 Safety controller 25.Aug.2011 tuytelaarsh

=WNCH+EJB13/1100 Terminalconnectionlist : =WNCH+EJB13#-X132 12.Sep.2011 tuytelaarsh

=WNCH+EJB13/1500 Bill of materials electric 12.Sep.2011 tuytelaarsh

=WNCH+EJB13/2500 Hazardous area schedule 12.Sep.2011 tuytelaarsh

=INF+/2600 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2601 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2602 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2603 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2604 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2605 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2606 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2607 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2608 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2609 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2610 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2611 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2612 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2613 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2614 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2615 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2616 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2617 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2618 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.b

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3.a
0 1 2 3 4 5 6 7 8 9

Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR

=INF+/2619 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2620 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2621 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2622 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2623 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2624 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2625 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2626 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2627 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2628 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2629 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2630 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2631 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2632 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2633 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2634 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2635 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2636 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2637 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2638 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2639 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2640 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2641 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2642 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2643 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2644 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2645 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2646 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2647 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

=INF+/2648 Electrical inspection sheet 12.Sep.2011 tuytelaarsh

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3.a PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE =WNCH/1

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3.b
0 1 2 3 4 5 6 7 8 9

Energieweg 26, 2964 LE, Groot-Ammers, The Netherlands, (t) +31 184 608 700, (f) +31 184 608 790

Winch

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
=GEN/3.b PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 21

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 26.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = WNCH + - 1
0 1 2 3 4 5 6 7 8 9 10 11 12 13

PLG53 PLG50 PLG51 PLG52 PLG56 PLG71 PLG4 PLG3 PLG62 PLG61
/210.9 /210.4 /210.0 /210.2 /210.5 /60.1 +ECP5/102.5 +ECP5/300.6 +ECP20/250.2 +ECP20/250.4

W234 W203 W201 W202 W204 W255 W253


RADOX RADOX RADOX RADOX RADOX W185 1 W148 W149 RADOX RADOX
6x0,5 mm² 6x0,5 mm² 6x0,5 mm² 6x0,5 mm² 10x0,5 mm² SABIX-SLPRNG RADOX RADOX 8 meter 8 meter
/210.9 /210.4 /210.0 /210.2 /210.5 7x1 mm² 5 meter 5 meter 5x1,5 mm² 3x1,5 mm²
/210.9 /60.1 5x2,5 mm² 12x1,5 mm² +ECP20/250.2 +ECP20/250.4
#M1

/210.9 /210.4 /210.0 /210.2 /210.5


/210.9 +ECP5/102.5 +ECP5/300.0
P14 P12 P10 P11 P13 +ECP5/300.6

-210U9 -210U5 -210U1 -210U3 -210U6 -60S1


Encoder 3 LOADPIN ENCODER 1 ENCODER 2 MMD Slipring PLG40
/210.8 /210.4 /210.0 /210.2 /210.5 /60.1
+ECP5 +ECP20/250.8

+ECP20
X51 X54 X202 X202 -250W8
reel empty
Wnch Juctionbox ECP5 WHM +ECP20/250.8

X51 X54 X54 X202 X202 X202

W150 W151 W152 W153 W157 W158 W159 W160 W161 W162 W163 W164 W165 W169 W250 W252 W251 W254
RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX ZH RADOX GEXOL
3x2,5 mm² 3x2,5 mm² 3x2,5 mm² 5x1,5 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 5x1,5 mm² 1x6 mm² 2x1,5 mm² 75 meter
+ECP5/102.5 +ECP5/102.8 +ECP5/102.9 +ECP5/303.6 +ECP5/303.0 +ECP5/304.3 +ECP5/304.4 +ECP5/304.5 +ECP5/304.6 +ECP5/304.7 +ECP5/304.8 +ECP5/302.3 +ECP5/305.4 +ECP5/301.1 +ECP20/250.1 +ECP20/250.2 +ECP20/250.3 1x8 AWG
+ECP20/250.8

+EJB13/200.3
SKT28
+EJB13
PLG28
+EJB13/200.3

X132
X132 X132
PE
+ECP20/250.1
-SKT40
W154 W155
Molded-2 Molded-2
-102H5 -102H9 2x.. mm² 2x.. mm² -303Y1 -304Y4 -304Y6 -304Y8 -305Y4 -301S1 -250Z3 -250U8
Winch light 1 Flood Light 2 +EJB13/200.1 +EJB13/200.2 Hydraulic Levelwind Spooling Low Wire Emergency SOUNDER Earth clamp
+ECP5/102.5 +ECP5/102.9 Motor Down Right Gear Spray Stop +ECP20/250.4 +ECP20/250.8
Displacemant 1 +ECP5/304.4 +ECP5/304.6 +ECP5/304.8 +ECP5/305.4 Cabin
+ECP5/303.1 +ECP5/301.1

PE
MASSA
-102H8 -200S1 -200S2 -304Y3 -304Y5 -304Y7 -302Y3 +ECP20/250.2
Flood Light 1 Measurehead Measurehead Levelwind Spooling High Slow
+ECP5/102.8 Left Right Up Left Gear Speed 1
+ECP5/303.6 +ECP5/303.7 +ECP5/304.3 +ECP5/304.5 +ECP5/304.7 +ECP5/302.3

1 THIS DRAWING IS OUR PROPERTY AND IS CONFIDENTIAL. IT IS NOT ALLOWED TO COPY OR TO SHOW TO THIRD PARTIES WITHOUT OUR WRITTEN PERMISSION. 25
Scale 1: 1 Electric Hydraulic HIGHER LEVEL LOCATION PAGE:
TYPE OF UNIT : DATASPLIT C ZONE2 AIRSTART Block Diagram ASSIGNMENT: DESIGNATION:
ENGINEER WINCH DATAS ES6931033765
WINCHFRAME AS-BUILT

PAGE MOD 25.Aug.2011


Energieweg 26, 2964 LE, Groot-Ammers, The Netherlands
(t) +31 184 608 700, (f) +31 184 608 790 PROJECTNUMBER: NLOA10526 = WNCH + - 21
0 1 2 3 4 5 6 7 8 9 10 11 12 13

21 THIS DRAWING IS OUR PROPERTY AND IS CONFIDENTIAL. IT IS NOT ALLOWED TO COPY OR TO SHOW TO THIRD PARTIES WITHOUT OUR WRITTEN PERMISSION. 31
Scale 1: 1 Electric Hydraulic HIGHER LEVEL LOCATION PAGE:
TYPE OF UNIT : DATASPLIT C ZONE2 AIRSTART Intrinsically Safe Circuits ASSIGNMENT: DESIGNATION:
ENGINEER WINCH DATAS ES6931033765

AS-BUILT

PAGE MOD 14.Jan.2011


Energieweg 26, 2964 LE, Groot-Ammers, The Netherlands
(t) +31 184 608 700, (f) +31 184 608 790 PROJECTNUMBER: NLOA10526 = WNCH + - 25
0 1 2 3 4 5 6 7 8 9

CONNECTORS

=WNCH-PLG3 = PLG3 Supply Winch


=WNCH-PLG4 = PLG4 Winch Lights
=WNCH-SKT28 = SKT28 Measuringhead
=WNCH-PLG40 = PLG40 Earth Reel
=WNCH-SKT40 = SKT40 Earth Reel
=WNCH-PLG50 = PLG50 Winch Loadcell
=WNCH-PLG51 = PLG51 Winch Encoder 2
=WNCH-PLG53 = PLG53 Winch Encoder 3
=WNCH-PLG56 = PLG56 Winch MMD
=WNCH-PLG52 = PLG52 Winch Encoder 3
=WNCH-PLG71 = PLG71 Winch Slipring 1
=WNCH+#-210U1-P10 = P10 Encoder 1
=WNCH+#-210U3-P11 = P11 Encoder 2
=WNCH+#-210U5-P12 = P12 Loadpin
=WNCH+#-210U6-P13 = P13 MMD
=WNCH+#-210U9-P14 = P14 Encoder 3

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
25 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 32

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 15.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Connectors = WNCH + - 31
0 1 2 3 4 5 6 7 8 9

ELECTRIC SYMBOL OVERVIEW


SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION

+ -
TERMINAL PROXIMITY SWITCH VALVE

CONNECTOR BATTERY CAPACITOR

SOCKET G GENERATOR INDUCTIVITY

PLUG TRANSFORMER RESISTOR

COIL (FOR CONTACTOR) CONVERTER / RECTIFIER DIODE (SEMICONDUCTOR)

NORMALY OPEN CONTACT SIGNAL LAMP EARTH / GROUND

NORMALY CLOSED CONTACT ACOUSTIC SIGNAL DEVICE (HORN)

CHANGE-OVER CONTACT MEASURING INSTRUMENT

M
SAFETY FUSE MOTOR
1~

CIRCUITBREAKER LIGHT

MOTOR-OVERLOAD SWITCH HEATING


I> I> I>

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
31 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 60

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 14.Jan.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electric symbol overview = WNCH + - 32
0 1 2 3 4 5 6 7 8 9

Slipring

Connections to:
CAB page 60

=WNCH

PLG71 1 2 3 4 5 6 7 8 9 ... 19
A0019154
/21.4
/60.1
=WNCH+

W185 1 2 3 4 5 6 ye/gn
/21.4

-60S1
Slipring
12 Rings Slipring
A0018944 PT06E-
/21.4 14-12SW (SR)

PT02E-
14-12PW

PT01E-
14-12PW S
-RING S S S S S S S S S S S
PT06E- R R R R R R R R R R R R
14-12SW (SR) 2 3 4 5 6 7 8 9 10 11 12
1

TOOL
-60A1

Slipring

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
32 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 210

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Slipring = WNCH + - 60
0 1 2 3 4 5 6 7 8 9

Encoder 1
Loadpin Encoder 2
Loadpin Loadpin Loadpin
MMD Encoder 3
Loadpin

Connections to: Connections to: Connections to: Connections to: Connections to:
CAB+DSHB CAB+DSHB CAB+DSHB CAB+DSHB CAB+DSHB
page 210 page 210 page 210 page 210 page 210

PLG51 PLG52 PLG50 PLG56 PLG53


Encoder 1 A B C D E G F Encoder 2 A B C D E G F Loadpin A B C D E F G H J K MMD A B C D E F G H J K Encoder 3 A B C D E F
A1068679 A1068679 A1068680 A1068674 A1068678
A1082717 A1082717 A1082717 A1082717 A1082716

W201 1 2 3 4 5 6 W202 1 2 3 4 5 6 W203 1 2 3 4 5 6 W204 1 2 3 4 5 6 7 8 W234 1 2 3 4


/21.1 /21.2 /21.1 /21.3 /21.0

/21.1 /21.2 /21.1


A1105838 A1105838 A1061788 /21.3 /21.0
A1061783 A1061783 A1061787 A1065759 A1058158
A1068688 A1068688 A1068690 A1068691 A1068689
P10 P11 P12 P13 P14
A B C D E G F A B C D E G F A B C E G J A B C D E F G H A C D E F
+5VDC

RTN

A\

B\

SHLD

+5VDC

RTN

A\

B\

SHLD

SIG+

EX-

EX+

SIG-

SH.CAL

SHLD

WEAKMARK

WEAKMARK/

GND

ANALOG-

+9-30Vdc

STRONGMARK

STRONGMARK/

V SENSOR

CH. B

GND

CH. A

SHLD
-210U1 -210U3 -210U5 -210U6 -210U9
ENCODER 1 ENCODER 2 LOADPIN MMD Encoder 3
/21.1 /21.2 A1082800 /21.3 /21.0

Kerrhead /21.1

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
60 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1400

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Operator Panel = WNCH + - 210
0 1 2 3 4 5 6 7 8 9

Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=WNCH+-PLG4 =WNCH+ECP5-X51
=WNCH-W148 RADOX 5x2,5 mm² 5 meter A1055970
TERMINAL STRIP X51 JUNCTION BOX ECP5

=WNCH+-PLG3 =WNCH+ECP5-X54
=WNCH-W149 RADOX 12x1,5 mm² 5 meter A1064044
0VDC GROUND ANALOGUE OUTPUTS TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+ECP5-X52

0VDC GROUND ANALOGUE OUTPUTS

=WNCH+ECP5-PE

+12/24VDC SUPPLY OUTPUTS

=WNCH+ECP5-X51 =WNCH+-102H5
=WNCH-W150 RADOX 3x2,5 mm² A1049117
TERMINAL STRIP X51 JUNCTION BOX ECP5 Winch light 1

=WNCH+ECP5-X51 =WNCH+-102H8
=WNCH-W151 RADOX 3x2,5 mm² A1049117
TERMINAL STRIP X51 JUNCTION BOX ECP5 Flood Light 1

=WNCH+ECP5-X51 =WNCH+-102H9
=WNCH-W152 RADOX 3x2,5 mm² A1049117
TERMINAL STRIP X51 JUNCTION BOX ECP5 Flood Light 2

=WNCH+-SKT28 =WNCH+ECP5-X54
=WNCH-W153 RADOX 5x1,5 mm² A1049158
Connector Measurehead SKT28 TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+ECP5-X52

Measurehead Right

=WNCH+EJB13-X132 =WNCH+-200S1
=WNCH-W154 Molded-2 2x.. mm² A1040277
TERMINAL STRIP X132 JUNCTION BOX EJB13 Measurehead Left

=WNCH+EJB13-X132 =WNCH+-200S2
=WNCH-W155 Molded-2 2x.. mm² A1040277
TERMINAL STRIP X132 JUNCTION BOX EJB13 Measurehead Right

=WNCH+ECP5-X54 =WNCH+-303Y1
=WNCH-W157 RADOX 3x1 mm² A1049118
TERMINAL STRIP X54 JUNCTION BOX JB5 Hydraulic Motor Displacemant 1

=WNCH+ECP5-304K0

Hydraulic Motor Displacemant 1

=WNCH+ECP5-X52 =WNCH+-304Y3
=WNCH-W158 RADOX 3x1 mm² A1049118
Levelwind Up Levelwind Up

=WNCH+ECP5-X54

TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+ECP5-X52 =WNCH+-304Y4
=WNCH-W159 RADOX 3x1 mm² A1049118
Levelwind Down Levelwind Down

Unit serial no.


THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
210 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1401

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =WNCH#-W148 < = > =WNCH#-W159 = WNCH + - 1400
0 1 2 3 4 5 6 7 8 9

Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=WNCH+ECP5-X54

TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+ECP5-X52 =WNCH+-304Y5
=WNCH-W160 RADOX 3x1 mm² A1049118
Spooling Left Spooling Left

=WNCH+ECP5-X54

TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+ECP5-X52 =WNCH+-304Y6
=WNCH-W161 RADOX 3x1 mm² A1049118
Spooling Right Spooling Right

=WNCH+ECP5-X54

TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+ECP5-X52 =WNCH+-304Y7
=WNCH-W162 RADOX 3x1 mm² A1049118
High Gear High Gear

=WNCH+ECP5-X54

TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+ECP5-X52 =WNCH+-304Y8
=WNCH-W163 RADOX 3x1 mm² A1049118
Low Gear Low Gear

=WNCH+ECP5-X54

TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+ECP5-X52 =WNCH+-302Y3
=WNCH-W164 RADOX 3x1 mm² A1049118
Spare Slow Speed 1

=WNCH+ECP5-X54

TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+ECP5-X52 =WNCH+-305Y4
=WNCH-W165 RADOX 3x1 mm² A1049118
Wire Spray Wire Spray

=WNCH+ECP5-X54

TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+ECP5-X52 =WNCH+-301S1
=WNCH-W169 RADOX 3x1 mm² A1049118
Emergency Stop Winch Emergency Stop Cabin

=WNCH+ECP5-X54

TERMINAL STRIP X54 JUNCTION BOX JB5

=WNCH+-PLG71 =WNCH+-60S1
=WNCH-W185 SABIX-SLPRNG 7x1 mm² A1111587
Slipring Slipring

Unit serial no.


THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1400 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1402

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =WNCH#-W159 < = > =WNCH#-W185 = WNCH + - 1401
0 1 2 3 4 5 6 7 8 9

Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=WNCH+-PLG51 =WNCH+-210U1-P10
=WNCH-W201 RADOX 6x0,5 mm² A1064046
Encoder 1 Loadpin

=WNCH+-PLG52 =WNCH+-210U3-P11
=WNCH-W202 RADOX 6x0,5 mm² A1064046
Encoder 2 Encoder 2

=WNCH+-PLG50 =WNCH+-210U5-P12
=WNCH-W203 RADOX 6x0,5 mm² A1064046
Loadpin Encoder 2

=WNCH+-PLG56 =WNCH+-210U6-P13
=WNCH-W204 RADOX 10x0,5 mm² A1064047
MMD Loadpin

=WNCH+-PLG53 =WNCH+-210U9-P14
=WNCH-W234 RADOX 6x0,5 mm² A1064046
Encoder 3 Encoder 3

=WNCH+-SKT40 =WNCH+ECP20-X202
=WNCH-W250 RADOX 5x1,5 mm² A1049158
TERMINAL STRIP X202 JUNCTION BOX ECP20

=WNCH+ECP20-X202 =WNCH+-250Z3
=WNCH-W251 RADOX 2x1,5 mm² A1064704
TERMINAL STRIP X202 JUNCTION BOX ECP20 SOUNDER

=WNCH+ECP20-X204

TERMINAL STRIP X204 JUNCTION BOX JB20

=WNCH+ECP20-X202 =WNCH+-PE
=WNCH-W252 ZH 1x6 mm² A0020481
TERMINAL STRIP X202 JUNCTION BOX ECP20

=WNCH+-PLG61 =WNCH+ECP20-X202
=WNCH-W253 RADOX 3x1,5 mm² 8 meter A1082865
Green Light TERMINAL STRIP X202 JUNCTION BOX ECP20

=WNCH+-250U8 =WNCH+-250W8
=WNCH-W254 GEXOL 1x8 AWG 75 meter A1024932
EARTH CLAMP EARTH CLAMP

=WNCH+-PLG62 =WNCH+ECP20-X202
=WNCH-W255 RADOX 5x1,5 mm² 8 meter A1049158
Wellhead Monitor TERMINAL STRIP X202 JUNCTION BOX ECP20

Unit serial no.


THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1401 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =WNCH#-W201 < = > =WNCH#-W255 = WNCH + - 1402
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN

=WNCH+-ECP5 1 ECP5 NOV ASEP Elmar 8501035865 =WNCH+ECP5/102 0

=WNCH+-EJB13 1 EJB 100x100x60 NOV ASEP Elmar 8501035839 =WNCH+EJB13/200 0

=WNCH+-102H5 1 LIGHT NOV ASEP Elmar A0000321 =WNCH+ECP5/102 5

=WNCH+-102H5 2 TL TUBE NOV ASEP Elmar A0016118 =WNCH+ECP5/102 5

=WNCH+-102H8 1 EX-FLOOD LIGHT NOV ASEP Elmar A1045242 =WNCH+ECP5/102 8

=WNCH+-102H9 1 EX-FLOOD LIGHT NOV ASEP Elmar A1045242 =WNCH+ECP5/102 9

=WNCH+-102H8 1 LIGHT BULB NOV ASEP Elmar A1058685 =WNCH+ECP5/102 8

=WNCH+-102H9 1 LIGHT BULB NOV ASEP Elmar A1058685 =WNCH+ECP5/102 9

=WNCH+-PLG71 1 PLUG 19X12 NOV ASEP Elmar A0019154 =WNCH+/60 1

=WNCH+-PLG3 1 PLUG NOV ASEP Elmar A1068665 =WNCH+ECP5/300 6

=WNCH+-PLG3 1 CAP SHELL SIZE 32 NOV ASEP Elmar A1061894 =WNCH+ECP5/300 6

=WNCH+-PLG56 1 RECEPTACLE 10PS NOV ASEP Elmar A1068674 =WNCH+/210 5

=WNCH+-PLG61 1 PLUG 3P NOV ASEP Elmar A1068676 =WNCH+ECP20/250 4

=WNCH+-PLG62 1 PLUG 5P NOV ASEP Elmar A1068677 =WNCH+ECP20/250 2

=WNCH+-PLG53 1 PLUG 6P NOV ASEP Elmar A1068678 =WNCH+/210 9

=WNCH+-PLG52 1 PLUG 8P NOV ASEP Elmar A1068679 =WNCH+/210 2

=WNCH+-PLG51 1 PLUG 8P NOV ASEP Elmar A1068679 =WNCH+/210 0

=WNCH+-PLG50 1 PLUG 10P NOV ASEP Elmar A1068680 =WNCH+/210 4

=WNCH+-PLG53 1 DUST CAP+CHAIN (PS) NOV ASEP Elmar A1082716 =WNCH+/210 9

=WNCH+-PLG50 1 DUST CAP+CHAIN (PS) NOV ASEP Elmar A1082717 =WNCH+/210 4

=WNCH+-PLG51 1 DUST CAP+CHAIN (PS) NOV ASEP Elmar A1082717 =WNCH+/210 0

=WNCH+-PLG52 1 DUST CAP+CHAIN (PS) NOV ASEP Elmar A1082717 =WNCH+/210 2

=WNCH+-PLG56 1 DUST CAP+CHAIN (PS) NOV ASEP Elmar A1082717 =WNCH+/210 5

=WNCH+-PLG61 1 DUST CAP+CHAIN (PS) NOV ASEP Elmar A1082717 =WNCH+ECP20/250 4

=WNCH+-PLG62 1 DUST CAP+CHAIN (PS) NOV ASEP Elmar A1082718 =WNCH+ECP20/250 2

=WNCH+-PLG4 1 PLUG 8P NOV ASEP Elmar A1089483 =WNCH+ECP5/102 5

=WNCH+-60S1 1 SLIPRING NOV ASEP Elmar A0018944 =WNCH+/60 1

=WNCH+-301S1 1 EMERGENCY SWITCH NOV ASEP Elmar A0021161 =WNCH+ECP5/301 1

=WNCH+-200S1 1 ACTION SWITCH NOV ASEP Elmar A1025975 =WNCH+EJB13/200 1

=WNCH+-200S2 1 ACTION SWITCH NOV ASEP Elmar A1025975 =WNCH+EJB13/200 2

=WNCH+-SKT28 1 SOCKET 19S NOV ASEP Elmar A1068696 =WNCH+EJB13/200 3

=WNCH+-SKT28 1 CAP SHELL SIZE 22 NOV ASEP Elmar A1079465 =WNCH+EJB13/200 3

=WNCH+-SKT28 1 CABLE CLAMP NOV ASEP Elmar A1089990 =WNCH+EJB13/200 3

=WNCH+-SKT40 1 RECEPTACLE NOV ASEP Elmar A1098756 =WNCH+ECP20/250 1

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1402 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1501

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = WNCH + - 1500
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN

=WNCH+-250U8 1 CLAMP NOV ASEP Elmar A0017613 =WNCH+ECP20/250 8

=WNCH+-210U9-P14 1 DUST CAP+CHAIN (R) NOV ASEP Elmar A1058158 =WNCH+/210 9

=WNCH+-210U1-P10 1 DUST CAP+CHAIN (PS) NOV ASEP Elmar A1061783 =WNCH+/210 0

=WNCH+-210U3-P11 1 DUST CAP+CHAIN (PS) NOV ASEP Elmar A1061783 =WNCH+/210 2

=WNCH+-210U5-P12 1 BACKSHELL NOV ASEP Elmar A1061787 =WNCH+/210 4

=WNCH+-210U5-P12 1 DUST CAP+CHAIN NOV ASEP Elmar A1061788 =WNCH+/210 4

=WNCH+-210U6-P13 1 DUST CAP+CHAIN (PS) NOV ASEP Elmar A1065759 =WNCH+/210 5

=WNCH+-210U1-P10 1 SOCKET 7S NOV ASEP Elmar A1068688 =WNCH+/210 0

=WNCH+-210U3-P11 1 SOCKET 7S NOV ASEP Elmar A1068688 =WNCH+/210 2

=WNCH+-210U9-P14 1 CONNECTOR NOV ASEP Elmar A1068689 =WNCH+/210 9

=WNCH+-210U5-P12 1 PLUG NOV ASEP Elmar A1068690 =WNCH+/210 4

=WNCH+-210U6-P13 1 SOCKET NOV ASEP Elmar A1068691 =WNCH+/210 5

=WNCH+-210U5 1 LOAD PIN NOV ASEP Elmar A1082800 =WNCH+/210 4

=WNCH+-210U1-P10 1 FIXED ADAPTOR NOV ASEP Elmar A1105838 =WNCH+/210 0

=WNCH+-210U3-P11 1 FIXED ADAPTOR NOV ASEP Elmar A1105838 =WNCH+/210 2

=WNCH+-250W8 1 REEL NOV ASEP Elmar A0016294 =WNCH+ECP20/250 8

=WNCH+-303Y1 1 VARIABLE DISPLACEMENT MOTOR NOV ASEP Elmar A1019407 =WNCH+ECP5/303 1

=WNCH+-304Y7 1 DIRECTIONAL SPOOL VALVE NOV ASEP Elmar A1025568 =WNCH+ECP5/304 7

=WNCH+-304Y8 1 DIRECTIONAL SPOOL VALVE NOV ASEP Elmar A1025568 =WNCH+ECP5/304 8

=WNCH+-304Y6 1 CONTROL BLOCK NOV ASEP Elmar A1046772 =WNCH+ECP5/304 6

=WNCH+-304Y5 1 CONTROL BLOCK NOV ASEP Elmar A1046772 =WNCH+ECP5/304 5

=WNCH+-304Y3 1 5/3 VALVE NOV ASEP Elmar A1051269 =WNCH+ECP5/304 3

=WNCH+-302Y3 1 SLOW SPEED MANIFOLD NOV ASEP Elmar A1073711 =WNCH+ECP5/302 3

=WNCH+-305Y4 1 SOLENOID 24VDC NOV ASEP Elmar A1090380 =WNCH+ECP5/305 4

=WNCH+-304Y8 1 PLUG 2P+PE NOV ASEP Elmar A1099133 =WNCH+ECP5/304 8

=WNCH+-305Y4 1 PLUG 2P+PE NOV ASEP Elmar A1099133 =WNCH+ECP5/305 4

=WNCH+-304Y7 1 PLUG 2P+PE NOV ASEP Elmar A1099133 =WNCH+ECP5/304 7

=WNCH+-303Y1 1 PLUG 2P+PE NOV ASEP Elmar A1099133 =WNCH+ECP5/303 1

=WNCH+-302Y3 1 PLUG 2P+PE NOV ASEP Elmar A1099133 =WNCH+ECP5/302 3

=WNCH+-304Y4 1 SOLENOID 24VDC NOV ASEP Elmar A1099136 =WNCH+ECP5/304 4

=WNCH+-304Y3 1 SOLENOID 24VDC NOV ASEP Elmar A1099136 =WNCH+ECP5/304 3

=WNCH+-250Z3 1 SOUNDER NOV ASEP Elmar A1100644 =WNCH+ECP20/250 4

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = WNCH + - 1501
0 1 2 3 4 5 6 7 8 9

Hazardous area schedule


CODE SERIAL SPECIFICATIONS MANUFAC. / TYPE NUMBER PROT. TYPE / CERTIFICATE VOLTAGE / CURRENT POWER A. NUMBER

Ceag Ex eds IIC T4


Fluorescent Light Assy ExsIIB4, 2x18 Watt, 110V-250V 47-63Hz
=WNCH+-102H5 A0000321
EEx de
ELLK92018/18 PTB 96 ATEX 2144 A

Chalmit Ltd II 2G EEx de IIC T3


=WNCH+-102H8 Flood Light 230V/50Hz 150W zone1 EEX-D A1045242
FLOODLIGHT 230V/50HZ 150W BAS99ATEX2228 A

Chalmit Ltd II 2G EEx de IIC T3


=WNCH+-102H9 Flood Light 230V/50Hz 150W zone1 EEX-D A1045242
FLOODLIGHT 230V/50HZ 150W BAS99ATEX2228 A

Honeywell II 2 GD EEx d IIC T6 T85°C


=WNCH+-200S1 Action Switch Honeywell ATEX EEx d A1025975
14CE101-6 KEMA03ATEX2514X A

Honeywell II 2 GD EEx d IIC T6 T85°C


=WNCH+-200S2 Action Switch Honeywell ATEX EEx d A1025975
14CE101-6 KEMA03ATEX2514X A

Amphenol Ex II 3 G Ex nA II T3
=WNCH+-210U1-P10 EX Straight plug, 16-1, Shell size 16 A1068688
DS-3106A-16S-1S-621 EPSILON 07 ATEX 2240X A

Amphenol Ex II 3 G Ex nA II T3
=WNCH+-210U3-P11 EX Straight plug, 16-1, Shell size 16 A1068688
DS-3106A-16S-1S-621 EPSILON 07 ATEX 2240X A

Epsilon Compliance Ex II 3 G Ex nA II T3
=WNCH+-210U5-P12 EX Loadpin plug A1068690
34120-18-1SN EPSILON 07 ATEX 2240X A

Epsilon Compliance Ex II 3 G Ex nA II T3
=WNCH+-210U6-P13 EX Straight Socket, 20-27, Shell Size 16 A1068691
DS-3106A20-27S EPSILON 07 ATEX 2240X A

Epsilon Compliance Ex II 3 G Ex nA II T3
=WNCH+-210U9-P14 EX Connector for backup depth display A1068689
PT06E1006PSR EPSILON 07 ATEX 2240X A

Medc EEx ia IIC T4


=WNCH+-250Z3 SOUNDER EEXIA 12V DB7PBC012NRR A1100644
DB7PBC012NR BAS 00 ATEX 1259 A

Stahl II 2G EEx edqm ia/ib [ia/ib] T4 690 V 1,5W


=WNCH+-301S1 Emergency switch EEx dem IIC T6 IP66 RED incl. box 80x93x72 A0021161
8040/1180.015-060 PTB01ATEX1105 23 A

Pneutec II 3 G Ex nA IIB T4 X
=WNCH+-302Y3 Plug 2p+PE EEx nA II ATEX (connector) A1099133
[EX] C18209W21A-Pneutec D1239927 A

Pneutec II 3 G Ex nA IIB T4 X
=WNCH+-303Y1 Plug 2p+PE EEx nA II ATEX (connector) A1099133
[EX] C18209W21A-Pneutec D1239927 A

Hawe II 2 G EEx m II 120°C (T4)


=WNCH+-304Y5 Control block PSL size 3, 2 sections A1046772
PSL 31/210-3 A1046772 TUV-A02ATEX0007X A

Hawe II 2 G EEx m II 120°C (T4)


=WNCH+-304Y6 Control block PSL size 3, 2 sections A1046772
PSL 31/210-3 A1046772 TUV-A02ATEX0007X A

Pneutec II 3 G Ex nA IIB T4 X
=WNCH+-304Y7 Plug 2p+PE EEx nA II ATEX (connector) A1099133
[EX] C18209W21A-Pneutec D1239927 A

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2501

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = WNCH + - 2500
0 1 2 3 4 5 6 7 8 9

Hazardous area schedule


CODE SERIAL SPECIFICATIONS MANUFAC. / TYPE NUMBER PROT. TYPE / CERTIFICATE VOLTAGE / CURRENT POWER A. NUMBER

Pneutec II 3 G Ex nA IIB T4 X
=WNCH+-304Y8 Plug 2p+PE EEx nA II ATEX (connector) A1099133
[EX] C18209W21A-Pneutec D1239927 A

Pneutec II 3 G Ex nA IIB T4 X
=WNCH+-305Y4 Plug 2p+PE EEx nA II ATEX (connector) A1099133
[EX] C18209W21A-Pneutec D1239927 A

Bartec Nederland B.V. Ex II 3G Ex de nA nC IIC T3 X


=WNCH+-ECP5 ECP5 WINCH CONTROL IFM ATX 8501035865
8501035865 A

Bartec Nederland B.V. II 3G Ex nA II T3 X


=WNCH+-EJB13 EJB 100x100x60 SS ATX ASSY MEASUREHEAD 8501035839
BARTEC A-STD-S1006 A

Amphenol Ex II 3G Ex nA T3
=WNCH+-PLG3 Mil PLUG 23P SIZE 32 STRAIGHT ADG ASSY ATX A1068665
Ex Assembly ADG Serie ATEX 2240X A

Amphenol Ex II 3G Ex nA T3
=WNCH+-PLG4 Mil PLUG 8P SIZE 32 STRAIGHT ADG ASSY ATX A1089483
Ex Assembly ADG Serie EPSILON 07 ATEX 2240X A

ASEP B.V. Ex ll 3G Ex nA ll T3
=WNCH+-PLG50 EX Straight Plug, 10P, Shell size 12 A1068680
PT06SE12-10P-SR EEx nA Epsilon 07 ATEX 2240X A

ASEP B.V. II 3 G Ex nA II T3
=WNCH+-PLG51 EX Straight Plug, 8P, Shell size 1 A1068679
PT06SE12-8P-SR (Ex nA) ATEX 2240X A

ASEP B.V. II 3 G Ex nA II T3
=WNCH+-PLG52 EX Straight Plug, 8P, Shell size 1 A1068679
PT06SE12-8P-SR (Ex nA) ATEX 2240X A

NOV ASEP Elmar Ex ll 3G Ex nA ll T3


=WNCH+-PLG53 EX Straight plug 6P, Shell size 10 A1068678
PT06SE10-6P-SR (Ex nA) Epsilon 07 ATEX 2240X A

ASEP B.V. Ex ll 3G Ex nA ll T3
=WNCH+-PLG56 EX Thru Bulkhead Receptacle 10PS, Shell size 12 A1068674
PTB12-10PS (Ex nA) Epsilon 07 ATEX 2240X A

NOV ASEP Elmar Ex ll 3G Ex nA ll T3


=WNCH+-PLG61 EX STRAIGHT PLUG 3P, SHELL SIZE 12 A1068676
PT06SE12-3P-SR (Ex nA) Epsilon 07 ATEX 2240X A

NOV ASEP Elmar Ex ll 3G Ex nA ll T3


=WNCH+-PLG62 EX STRAIGHT PLUG 5P, SHELL SIZE 14 A1068677
PT06SE14-5P-SR (Ex nA) Epsilon 07 ATEX 2240X A

Amphenol EEx d IIC T6


=WNCH+-PLG71 EX measure plug 19X12 A0019154
016-377PN Sira 03 ATEX 1101 X 30 A

NOV ASEP Elmar EPSILON07ATEX2240X


=WNCH+-SKT28 SOCKET 19S SHELL SIZE 22 ATX A1068696
DS3106A-22-14S (Ex nA) II 3 G Ex nA II T3 A

Amphenol EEx d IIC T6


=WNCH+-SKT40 PANEL MOUNT 19X12 FEMALE 16 CA A1098756
EX-17-1-16-312SN Sira 03 ATEX 1101 X A

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +ECP5/1

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = WNCH + - 2501
0 1 2 3 4 5 6 7 8 9

National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar

Winch

ECP5 = WNCH 24V IFM SD/DD ATX


8501035865/1

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+/2501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 30

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = WNCH + ECP5 - 1
0 1 2 3 4 5 6 7 8 9

TERMINAL STRIP NUMBERING CONNECTORS

=WNCH+ECP5-X51 = TERMINAL STRIP X51 JUNCTION BOX ECP5 =WNCH+ECP5#-SKTC2 = SKTC2 Interface Programming (RS232)
=WNCH+ECP5-X52 = TERMINAL STRIP X52 JUNCTION BOX JB5
=WNCH+ECP5-X54 = TERMINAL STRIP X54 JUNCTION BOX JB5

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 102

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminal Strips & Connectors = WNCH + ECP5 - 30
0 1 2 3 4 5 6 7 8 9

+-ECP5
8501035865

Connections to: Connections to:


CAB+ECP2 CAB+ECP2
page 102 page 102

PLG4 B C F H D E
A1089483 1 2 5 3 4 W148
+/21.7 +/21.7

X51 1 2 PE X51 3 4 PE 5 6 PE 7 8 PE

1 2 3
+ECP5 1 2 3 1 2 3
W150 W151 W152
+/21.0 +/21.0 +/21.1

-102H5
TL 2x18W -102H8 L1 N PE -102H9 L1 N PE
115/230V EX 230V 150W 230V 150W
A0000321 A1045242 A1045242
A0016118 A1058685 A1058685
+/21.0 +/21.1
+/21.0
Winch light 1 Flood Light 1 Flood Light 2
Winch

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
30 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 300

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cabin & Winch Lights = WNCH + ECP5 - 102
0 1 2 3 4 5 6 7 8 9

300U0 = PLug on IFM


SKTC1 = Connector IFM

-300U0
EX IFM CR7020
A1066396
A1056781
/300.0 CAN 1 CAN 1 CAN 2 CAN 2
/301.0 VBB s VBB o VBB r GND s GND o GND a GND RxD TxD ERROR TEST
/302.0
/303.0
H L H L
/304.0
/305.0

VBB s VBB o VBB r GND s GND o GND a GND RxD TxD ERROR TEST CAN 1 H CAN 1 L CAN 2 H CAN 2 L

SKTC1 23 05 34 01 15 12 33 06 07 13 24 14 32 26 25
/300.0
X54 23 05 34 01 15 12 33 06 07 13 24 14 32 26 25
11
-300K4
/300.3 12 14

+24Vdc-IFM TEST INPUT :


- NORMAL TO GROUND
- FOR SOFTWARE TO +12/24VDC
-300R9
-300F0 -300F1 -300F2 120 Ohm
IFM IFM IFM EEx nA
VBB s VBB o CIRCUIT A1065791
2A 16A 10A
EEx de EEx de EEx de
A1085712 A1085715 A1085714
A1079006 A1079006 A1079006

24VDC-E

0VDC-E

A2 -300K4
24VDC
EEx nC
0VDC-E A1 A1029768
14 11 /300.5
12

24VDC-IFM

PE
/30.6
/300.3
A1043677 X52 1 2
A1083957 B C D E
A
SKTC2
Ex e Ex e

W149 1 2 3 4 9 12 W149 5 6
+/21.8 +/21.8
+/21.8
/300.0
+/21.8 A1061894
/300.6 A1068665
PLG3 R P E T PLG3 A B

Connections to: Connections to:


CAB+ECP2 CAB+ECP2
page 101 Interface page 300
Programming
(RS232)

Supply
JB4
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
102 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 301

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 24.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller EX = WNCH + ECP5 - 300
0 1 2 3 4 5 6 7 8 9

-300U0 INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT


/300.0

Emergency
Spare Spare Spare Spare Spare Spare Spare
Stop Winch

IX0.00 IW03 DI / AI IX0.01 IW04 DI / AI IX0.02 IW05 DI / AI IX0.03 IW06 DI / AI IX0.04 IW07 DI / AI IX0.05 IW08 DI / AI IX0.06 IW09 DI / AI IX0.07 IW10 DI / AI

SKTC1 08 27 09 28 10 29 11 30
/300.0
X54 08 27 09 28 10 29 11 30

+24VDC-IFM

X52 3

Ex e Ex e

W169 1 2
+/21.8

BK

GY

-301S1
Emergency
Stop Winch
A0021161
+/21.8

Spare Spare Spare Spare Spare Spare Spare Spare

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
300 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 302

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 24.Feb.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller = WNCH + ECP5 - 301
0 1 2 3 4 5 6 7 8 9

-300U0 OUTPUT OUTPUT OUTPUT OUTPUT INPUT INPUT INPUT INPUT


/300.0

Slow Hydr. Motor Hydr. Motor


Brake 1 Brake 2 Spare Spare Spare
Speed 1 Speed 1 Speed 2
IX0.11 DI

QX0.00 DO/AO QX0.01 DO/AO QX0.02 DO/AO QX0.03 DO/AO IX0.12 DI IX0.13 DI IX0.14 DI IX0.15 DI

SKTC1 44 45 46 47 20 02 21 38
/300.0
X54 44 45 46 47 20 02 21 38

11 +24VDC-IFM +24VDC-IFM +24VDC-IFM +24VDC-IFM


-304K1
/304.1 0VDC-E 0VDC-E 0VDC-E 0VDC-E
12 14

+A1 -A2 3 +A1 -A2 3 +A1 -A2 3 +A1 -A2 3

1 1 1 1

-302U5 -302U6 -302U7 -302U8


EEx n EEx n EEx n EEx n
A1066385 A1066385 A1066385 A1066385
/302.8

24VDC-IFM 24VDC-IFM
0VDC 0VDC
0VDC-E 0VDC-E

X52 4 5 sp sp X52 6 7 sp sp

Ex e Ex e

W164 1 2
+/21.6

-302Y3
-10M26
24 VDC
A1073711
A1099133
+/21.6

Brake 1 Brake 2 Spare Slow Spare Speedsensor Spare Spare Spare


Speed Hydr. Motor

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
301 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 303

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 24.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller = WNCH + ECP5 - 302
0 1 2 3 4 5 6 7 8 9

-300U0 OUTPUT OUTPUT OUTPUT OUTPUT INPUT INPUT INPUT INPUT


/300.0

Hydraulic
Hydraulic
Motor Brake Measurehead Measurehead High
Motor Spare Spare
Displacemant 2 Feedback Left Right Speed
Displacemant 1
Spare

QX0.04 DO/AO QX0.05 DO/AO QX0.06 DO/AO QX0.07 DO/AO IX1.04 DI IX1.05 DI IX1.06 DI IX1.07 DI

SKTC1 36 54 17 53 19 55 18 37
/300.0
X54 36 54 17 53 19 55 18 37

11
-304K0
/304.1
12 14

PE

0VDC-E +24VDC-IFM +24VDC-IFM

Inside JB Inside JB

W157 2 1 W153 1 2 3 4 5
+/21.3 +/21.2

+EJB13/200.3 A B JB13- 1 C D V
SKT28
PLG28
+EJB13 +EJB13/200.3 A B C D V

-303Y1 X132 1 2 3 4 PE
-10A26
EEx n [R]
13 13
A1019407
A1099133 -200S1 -200S2
+/21.3 +EJB13/200.1 +EJB13/200.2
14 14

MEA
+EJB13/200.1

Hydraulic Spare Spare Spare Spare Measurehead Measurehead Spare


Motor Left Right
Displacemant 1

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
302 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 304

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller = WNCH + ECP5 - 303
0 1 2 3 4 5 6 7 8 9

-300U0 OUTPUT INPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT


/300.0

Second Levelwind Levelwind Spooling Spooling High Low


Spare
drum Up Down Left Right Gear Gear

IX1.08 DI IX1.09 DI IX1.10 DI IX1.11 DI IX1.12 DI IX1.13 DI IX1.14 DI IX1.15 DI

SKTC1 39 03 40 22 41 42 43 04
/300.0
X54 39 03 40 22 41 42 43 04

-304K0 A1 -304K1 A1
A1029768 A1029768
24VDC 24VDC
EEx nC A2 EEx nC A2
A1029768 A1029768

14 14

12 11 /303.1 12 11 /302.1

0VDC-E 0VDC-E

0VDC-E 0VDC-E 0VDC-E 0VDC-E 0VDC-E 0VDC-E

Inside JB Inside JB

W158 2 1 W159 2 1 W160 2 1 W161 2 1 W162 2 1 W163 2 1


+/21.3 +/21.4 +/21.4 +/21.5 +/21.5 +/21.6

-304Y3 -304Y4 -304Y5 -304Y6 -304Y7 -304Y8


-10V19.3 -10V19.3 10M20.1 10M20.2 24Vdc 24Vdc
24VDC 24VDC 24VDC 24VDC 1,29A 1,29A
A1051269 A1099136 A1046772 A1046772 A1025568 A1025568
A1099136 +/21.4 +/21.4 +/21.5 A1099133 A1099133
+/21.3 +/21.5 +/21.6

Spare Spare Levelwind Levelwind Spooling Spooling High Low


Up Down Left Right Gear Gear

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
303 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 305

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller = WNCH + ECP5 - 304
0 1 2 3 4 5 6 7 8 9

-300U0 OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT


/300.0

Slewing Wire Slewing Slewing Enable


Spare Freewheel Spare
ON/OFF Spray Left Right Manifold

QX1.00 DO/AO QX1.01 DO QX1.02 DO QX1.03 DO/AO QX1.04 DO/AO QX1.05 DO QX1.06 DO QX1.07 DO/AO

SKTC1 48 49 31 50 51 52 16 35
/300.0
X54 48 49 31 50 51 52 16 35

0VDC-E

Inside JB Inside JB

W165 2 1
+/21.7

-305Y4
-10M26
EEx n [R]
A1090380
A1099133
+/21.7

Spare Spare Spare Wire Spare Spare Spare Enable


Spray Manifold

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
304 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller = WNCH + ECP5 - 305
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=WNCH-W152

=WNCH-W151

=WNCH-W150

CABLE NAME

CABLE NAME

=WNCH-W148
=WNCH+ECP5-X51
TERMINAL STRIP X51 JUNCTION BOX ECP5

RADOX 3x2,5 mm²

RADOX 3x2,5 mm²

RADOX 3x2,5 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE

RADOX 5x2,5 mm²


FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

1 =WNCH+-102H5 1 =WNCH+-PLG4 B 1 =WNCH+ECP5/102.5

2 =WNCH+-102H5 2 =WNCH+-PLG4 C 2 =WNCH+ECP5/102.5

Winch light 1 =WNCH+-PLG4 F PE =WNCH+ECP5/102.5

=WNCH+ECP5-X51

3 =WNCH+-102H5

Winch light 1 3 =WNCH+ECP5-X51 1 =WNCH+ECP5/102.6

= 4 =WNCH+ECP5-X51 2 =WNCH+ECP5/102.7

= PE =WNCH+ECP5-X51 PE =WNCH+ECP5/102.7

Flood Light 1 1 =WNCH+-102H8 L1 5 =WNCH+-PLG4 D 3 =WNCH+ECP5/102.8

= 2 =WNCH+-102H8 N 6 =WNCH+-PLG4 E 4 =WNCH+ECP5/102.8

= 3 =WNCH+-102H8 PE PE =WNCH+ECP5-X51 PE =WNCH+ECP5/102.8

Flood Light 2 1 =WNCH+-102H9 L1 7 =WNCH+ECP5-X51 5 =WNCH+ECP5/102.9

= 2 =WNCH+-102H9 N 8 =WNCH+ECP5-X51 6 =WNCH+ECP5/102.9

= 3 =WNCH+-102H9 PE PE =WNCH+ECP5-X51 PE =WNCH+ECP5/102.9

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
305 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1101

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =WNCH+ECP5#-X51 TERMINAL STRIP X51 JUNCTION = WNCH + ECP5 - 1100
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=WNCH-W161

=WNCH-W160

=WNCH-W159

=WNCH-W158

=WNCH-W153

=WNCH-W164

=WNCH-W169

=WNCH-W149

CABLE NAME

CABLE NAME
=WNCH+ECP5-X52
TERMINAL STRIP X52 JUNCTION BOX JB5

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 5x1,5 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 12x1,5 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

0VDC GROUND ANALOGUE OUTPUTS 5 =WNCH+-PLG3 A 1 =WNCH+ECP5-X54 14 =WNCH+ECP5/300.6

= 6 =WNCH+-PLG3 B 2 =WNCH+ECP5-X54 32 =WNCH+ECP5/300.6

Emergency Stop Winch 2 =WNCH+-301S1 GY 3 =WNCH+ECP5-X54 08 =WNCH+ECP5/301.1

- =WNCH+ECP5/302.0

Spare 1 =WNCH+-302Y3 - =WNCH+ECP5/302.3

Speedsensor Hydr. Motor =WNCH+ECP5-302U5 -A2 - =WNCH+ECP5/302.5

Hydr. Motor Speed 1 - =WNCH+ECP5/302.5

= 4 =WNCH+ECP5-302U5 1 =WNCH+ECP5/302.5

= 5 =WNCH+ECP5-302U6 1 =WNCH+ECP5/302.5

= sp =WNCH+ECP5/302.6

= =WNCH+ECP5-302U6 -A2 - =WNCH+ECP5/302.6

= sp =WNCH+ECP5/302.6

Hydr. Motor Speed 2 =WNCH+ECP5-302U7 -A2 - =WNCH+ECP5/302.7

Spare - =WNCH+ECP5/302.7

= 6 =WNCH+ECP5-302U7 1 =WNCH+ECP5/302.7

= 7 =WNCH+ECP5-302U8 1 =WNCH+ECP5/302.7

= sp =WNCH+ECP5/302.8

= =WNCH+ECP5-302U8 -A2 - =WNCH+ECP5/302.8

= sp =WNCH+ECP5/302.8

Measurehead Right 5 =WNCH+-SKT28 V PE =WNCH+ECP5/303.7

- =WNCH+ECP5-304K0 A2 =WNCH+ECP5/304.1

Spare - =WNCH+ECP5-304K1 A2 =WNCH+ECP5/304.1

Levelwind Up 2 =WNCH+-304Y3 - =WNCH+ECP5/304.3

Levelwind Down 2 =WNCH+-304Y4 - =WNCH+ECP5/304.4

Spooling Left 2 =WNCH+-304Y5 - =WNCH+ECP5/304.5

Spooling Right 2 =WNCH+-304Y6 - =WNCH+ECP5/304.6

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1102

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =WNCH+ECP5#-X52 TERMINAL STRIP X52 JUNCTION = WNCH + ECP5 - 1101
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=WNCH-W149

=WNCH-W165

=WNCH-W163

=WNCH-W162

CABLE NAME

CABLE NAME

=WNCH-W149
=WNCH+ECP5-X52
TERMINAL STRIP X52 JUNCTION BOX JB5

RADOX 12x1,5 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE

RADOX 12x1,5 mm²


FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

High Gear 2 =WNCH+-304Y7 - =WNCH+ECP5/304.7

Low Gear 2 =WNCH+-304Y8 - =WNCH+ECP5/304.8

Wire Spray 2 =WNCH+-305Y4 - =WNCH+ECP5/305.4

+ =WNCH+-PLG3 R 1 =WNCH+ECP5/300.0

+12/24VDC SUPPLY SENSORS AND MODULE + =WNCH+ECP5-300F0 2 =WNCH+ECP5/300.0

= 3 =WNCH+-PLG3 P - =WNCH+ECP5/300.0

4 =WNCH+-PLG3

+12/24VDC SUPPLY VIA RELAY - =WNCH+ECP5/300.2

0VDC GROUD SEN-SORS AND MODULE - =WNCH+ECP5-X54 01 =WNCH+ECP5/300.2

= - =WNCH+ECP5/300.2

= - =WNCH+ECP5-X54 15 =WNCH+ECP5/300.2

= - =WNCH+ECP5/300.2

= - =WNCH+ECP5-X54 12 =WNCH+ECP5/300.2

= - =WNCH+ECP5/300.2

= - =WNCH+ECP5-X54 33 =WNCH+ECP5/300.2

= - =WNCH+ECP5/300.2

= - =WNCH+ECP5-300K4 12 =WNCH+ECP5/300.2

= - =WNCH+ECP5/300.2

0VDC GROUD OUTPUTS - =WNCH+ECP5/300.2

= - =WNCH+ECP5/300.2

= - =WNCH+ECP5-300K4 A2 =WNCH+ECP5/300.2

= - =WNCH+ECP5/300.2

= - =WNCH+ECP5-SKTC2 C =WNCH+ECP5/300.2

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1103

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =WNCH+ECP5#-X52 TERMINAL STRIP X52 JUNCTION = WNCH + ECP5 - 1102
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=WNCH-W169

=WNCH-W149

=WNCH-W159

=WNCH-W153

=WNCH-W163

CABLE NAME

CABLE NAME
=WNCH+ECP5-X54
TERMINAL STRIP X54 JUNCTION BOX JB5

RADOX 3x1 mm²

RADOX 12x1,5 mm²

RADOX 3x1 mm²

RADOX 5x1,5 mm²

RADOX 3x1 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

0VDC GROUD SEN-SORS AND MODULE =WNCH+ECP5-X52 - 01 =WNCH+ECP5-SKTC1 01 =WNCH+ECP5/300.2

Hydr. Motor Speed 2 =WNCH+ECP5-302U6 3 02 =WNCH+ECP5-SKTC1 02 =WNCH+ECP5/302.6

= =WNCH+ECP5-302U7 +A1 + =WNCH+ECP5/302.7

= + =WNCH+ECP5/302.7

Spare 03 =WNCH+ECP5-SKTC1 03 =WNCH+ECP5/304.2

Low Gear 1 =WNCH+-304Y8 04 =WNCH+ECP5-SKTC1 04 =WNCH+ECP5/304.8

+12/24VDC SUPPLY OUTPUTS =WNCH+ECP5-300F1 05 =WNCH+ECP5-SKTC1 05 =WNCH+ECP5/300.1

=WNCH+ECP5-X54

0VDC GROUND ANALOGUE OUTPUTS =WNCH+ECP5-SKTC2 A 06 =WNCH+ECP5-SKTC1 06 =WNCH+ECP5/300.4

= =WNCH+ECP5-SKTC2 B 07 =WNCH+ECP5-SKTC1 07 =WNCH+ECP5/300.4

Emergency Stop Winch =WNCH+ECP5-X52 3 08 =WNCH+ECP5-SKTC1 08 =WNCH+ECP5/301.1

Spare 09 =WNCH+ECP5-SKTC1 09 =WNCH+ECP5/301.3

= 10 =WNCH+ECP5-SKTC1 10 =WNCH+ECP5/301.5

= 11 =WNCH+ECP5-SKTC1 11 =WNCH+ECP5/301.7

Interface Programming (RS232) =WNCH+ECP5-X52 - 12 =WNCH+ECP5-SKTC1 12 =WNCH+ECP5/300.3

0VDC GROUND ANALOGUE OUTPUTS 13 =WNCH+ECP5-SKTC1 13 =WNCH+ECP5/300.5

= =WNCH+ECP5-X52 1 14 =WNCH+ECP5-SKTC1 14 =WNCH+ECP5/300.7

=WNCH+ECP5-X54

0VDC GROUD OUTPUTS =WNCH+ECP5-X52 - 15 =WNCH+ECP5-SKTC1 15 =WNCH+ECP5/300.2

Slewing Right 16 =WNCH+ECP5-SKTC1 16 =WNCH+ECP5/305.7

Spare 17 =WNCH+ECP5-SKTC1 17 =WNCH+ECP5/303.3

Measurehead Right 4 =WNCH+-SKT28 D 18 =WNCH+ECP5-SKTC1 18 =WNCH+ECP5/303.7

Brake Feedback 19 =WNCH+ECP5-SKTC1 19 =WNCH+ECP5/303.5

Measurehead Left 1 =WNCH+-SKT28 A + =WNCH+ECP5/303.6

Hydr. Motor Speed 1 =WNCH+ECP5-302U5 3 20 =WNCH+ECP5-SKTC1 20 =WNCH+ECP5/302.5

= =WNCH+ECP5-302U6 +A1 + =WNCH+ECP5/302.6

Spare =WNCH+ECP5-302U7 3 21 =WNCH+ECP5-SKTC1 21 =WNCH+ECP5/302.7

= =WNCH+ECP5-302U8 +A1 + =WNCH+ECP5/302.8

Levelwind Down 1 =WNCH+-304Y4 22 =WNCH+ECP5-SKTC1 22 =WNCH+ECP5/304.4

+12/24VDC SUPPLY SENSORS AND MODULE =WNCH+ECP5-300F0 23 =WNCH+ECP5-SKTC1 23 =WNCH+ECP5/300.0

= 9 =WNCH+-PLG3 E + =WNCH+ECP5/300.1

0VDC GROUND ANALOGUE OUTPUTS =WNCH+ECP5-300K4 11 24 =WNCH+ECP5-SKTC1 24 =WNCH+ECP5/300.5

= =WNCH+ECP5-X54 32 25 =WNCH+ECP5-SKTC1 25 =WNCH+ECP5/300.8

=WNCH+ECP5-300R9

Spare 1 =WNCH+-301S1 BK + =WNCH+ECP5/301.1

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1102 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1104

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =WNCH+ECP5#-X54 TERMINAL STRIP X54 JUNCTION = WNCH + ECP5 - 1103
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=WNCH-W165

=WNCH-W164

=WNCH-W162

=WNCH-W161

=WNCH-W160

=WNCH-W158

=WNCH-W157

CABLE NAME

CABLE NAME
=WNCH+ECP5-X54
TERMINAL STRIP X54 JUNCTION BOX JB5

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

0VDC GROUND ANALOGUE OUTPUTS =WNCH+ECP5-X54 14 26 =WNCH+ECP5-SKTC1 26 =WNCH+ECP5/300.8

=WNCH+ECP5-300R9

Spare 27 =WNCH+ECP5-SKTC1 27 =WNCH+ECP5/301.2

= 28 =WNCH+ECP5-SKTC1 28 =WNCH+ECP5/301.4

= 29 =WNCH+ECP5-SKTC1 29 =WNCH+ECP5/301.6

= 30 =WNCH+ECP5-SKTC1 30 =WNCH+ECP5/301.8

Freewheel 31 =WNCH+ECP5-SKTC1 31 =WNCH+ECP5/305.3

0VDC GROUND ANALOGUE OUTPUTS =WNCH+ECP5-X52 2 32 =WNCH+ECP5-SKTC1 32 =WNCH+ECP5/300.7

=WNCH+ECP5-X54

0VDC GROUND ANALOGUE OUTPUTS =WNCH+ECP5-X52 - 33 =WNCH+ECP5-SKTC1 33 =WNCH+ECP5/300.3

+12/24VDC SUPPLY VIA RELAY =WNCH+ECP5-X54 05 34 =WNCH+ECP5-SKTC1 34 =WNCH+ECP5/300.1

Enable Manifold 35 =WNCH+ECP5-SKTC1 35 =WNCH+ECP5/305.8

Hydraulic Motor Displacemant 1 =WNCH+ECP5-304K0 11 36 =WNCH+ECP5-SKTC1 36 =WNCH+ECP5/303.1

High Speed 37 =WNCH+ECP5-SKTC1 37 =WNCH+ECP5/303.8

Spare =WNCH+ECP5-302U8 3 38 =WNCH+ECP5-SKTC1 38 =WNCH+ECP5/302.8

2 =WNCH+-303Y1 - =WNCH+ECP5/303.0

Second drum =WNCH+ECP5-304K0 A1 39 =WNCH+ECP5-SKTC1 39 =WNCH+ECP5/304.1

=WNCH+ECP5-304K1

Levelwind Up 1 =WNCH+-304Y3 40 =WNCH+ECP5-SKTC1 40 =WNCH+ECP5/304.3

Spooling Left 1 =WNCH+-304Y5 41 =WNCH+ECP5-SKTC1 41 =WNCH+ECP5/304.5

Spooling Right 1 =WNCH+-304Y6 42 =WNCH+ECP5-SKTC1 42 =WNCH+ECP5/304.6

High Gear 1 =WNCH+-304Y7 43 =WNCH+ECP5-SKTC1 43 =WNCH+ECP5/304.7

Brake 1 =WNCH+ECP5-304K1 11 44 =WNCH+ECP5-SKTC1 44 =WNCH+ECP5/302.1

Brake 2 45 =WNCH+ECP5-SKTC1 45 =WNCH+ECP5/302.2

Slow Speed 1 2 =WNCH+-302Y3 46 =WNCH+ECP5-SKTC1 46 =WNCH+ECP5/302.3

Spare 47 =WNCH+ECP5-SKTC1 47 =WNCH+ECP5/302.4

= =WNCH+ECP5-302U5 +A1 + =WNCH+ECP5/302.5

Speedsensor Hydr. Motor + =WNCH+ECP5/302.5

Spare 48 =WNCH+ECP5-SKTC1 48 =WNCH+ECP5/305.1

Slewing ON/OFF 49 =WNCH+ECP5-SKTC1 49 =WNCH+ECP5/305.2

Wire Spray 1 =WNCH+-305Y4 50 =WNCH+ECP5-SKTC1 50 =WNCH+ECP5/305.4

Spare 51 =WNCH+ECP5-SKTC1 51 =WNCH+ECP5/305.5

Slewing Left 52 =WNCH+ECP5-SKTC1 52 =WNCH+ECP5/305.6

Spare 53 =WNCH+ECP5-SKTC1 53 =WNCH+ECP5/303.4

= 54 =WNCH+ECP5-SKTC1 54 =WNCH+ECP5/303.2

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1103 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1105

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =WNCH+ECP5#-X54 TERMINAL STRIP X54 JUNCTION = WNCH + ECP5 - 1104
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=WNCH-W153

CABLE NAME

CABLE NAME
=WNCH+ECP5-X54
TERMINAL STRIP X54 JUNCTION BOX JB5

RADOX 5x1,5 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Measurehead Left 2 =WNCH+-SKT28 B 55 =WNCH+ECP5-SKTC1 55 =WNCH+ECP5/303.6

Measurehead Right 3 =WNCH+-SKT28 C + =WNCH+ECP5/303.7

+12/24VDC SUPPLY VIA RELAY + =WNCH+ECP5-300F2 =WNCH+ECP5/300.1

= + =WNCH+ECP5-300K4 14 =WNCH+ECP5/300.2

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1104 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =WNCH+ECP5#-X54 TERMINAL STRIP X54 JUNCTION = WNCH + ECP5 - 1105
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN

=WNCH+ECP5-300F0 1 FUSE HOLDER NOV ASEP Elmar A1079006 =WNCH+ECP5/300 0

=WNCH+ECP5-300F0 1 FUSE 4A NOV ASEP Elmar A1085712 =WNCH+ECP5/300 0

=WNCH+ECP5-300F2 1 FUSE 10A NOV ASEP Elmar A1085714 =WNCH+ECP5/300 1

=WNCH+ECP5-300F2 1 FUSE HOLDER NOV ASEP Elmar A1079006 =WNCH+ECP5/300 1

=WNCH+ECP5-300F1 1 FUSE 16A NOV ASEP Elmar A1085715 =WNCH+ECP5/300 1

=WNCH+ECP5-300F1 1 FUSE HOLDER NOV ASEP Elmar A1079006 =WNCH+ECP5/300 1

=WNCH+ECP5-300K4 1 ELECTRONIC TERMINAL RELAY NOV ASEP Elmar A1029768 =WNCH+ECP5/300 3

=WNCH+ECP5-304K0 1 ELECTRONIC TERMINAL RELAY NOV ASEP Elmar A1029768 =WNCH+ECP5/304 1

=WNCH+ECP5-304K1 1 ELECTRONIC TERMINAL RELAY NOV ASEP Elmar A1029768 =WNCH+ECP5/304 1

=WNCH+ECP5-300R9 1 RESISTOR NOV ASEP Elmar A1065791 =WNCH+ECP5/300 9

=WNCH+ECP5-SKTC2 1 CAP SHELL SIZE 12 NOV ASEP Elmar A1043677 =WNCH+ECP5/300 3

=WNCH+ECP5-SKTC2 1 RECEPTACLE NOV ASEP Elmar A1083957 =WNCH+ECP5/300 3

=WNCH+ECP5-300U0 1 SAFETY CONTROLLER NOV ASEP Elmar A1066396 =WNCH+ECP5/300 0

=WNCH+ECP5-300U0 1 CONNECTOR FOR IFM NOV ASEP Elmar A1056781 =WNCH+ECP5/300 0

=WNCH+ECP5-302U6 1 ELECTRONIC SIGNAL CONVERTER NOV ASEP Elmar A1066385 =WNCH+ECP5/302 6

=WNCH+ECP5-302U5 1 ELECTRONIC SIGNAL CONVERTER NOV ASEP Elmar A1066385 =WNCH+ECP5/302 5

=WNCH+ECP5-302U7 1 ELECTRONIC SIGNAL CONVERTER NOV ASEP Elmar A1066385 =WNCH+ECP5/302 7

=WNCH+ECP5-302U8 1 ELECTRONIC SIGNAL CONVERTER NOV ASEP Elmar A1066385 =WNCH+ECP5/302 8

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1105 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = WNCH + ECP5 - 1500
0 1 2 3 4 5 6 7 8 9

Hazardous area schedule


CODE SERIAL SPECIFICATIONS MANUFAC. / TYPE NUMBER PROT. TYPE / CERTIFICATE VOLTAGE / CURRENT POWER A. NUMBER

A.T.X. S.A. II 2G EEx de IIC T4 250 V


=WNCH+ECP5-300F0 Fuse holder EEx de (Fuse Carrier) max 40A A1079006
909069 + 096299 LCIE 02 ATEX 0003 U 2A

A.T.X. S.A. II 2G EEx de IIC T4 250 V


=WNCH+ECP5-300F1 Fuse holder EEx de (Fuse Carrier) max 40A A1079006
909069 + 096299 LCIE 02 ATEX 0003 U 2A

A.T.X. S.A. II 2G EEx de IIC T4 250 V


=WNCH+ECP5-300F2 Fuse holder EEx de (Fuse Carrier) max 40A A1079006
909069 + 096299 LCIE 02 ATEX 0003 U 2A

Wago Ex II 3 GD EEx nA nC II T4 24 VDC


=WNCH+ECP5-300K4 Electronic Terminal Relay 24VDC EEx nC A1029768
859-304 02 ATEX 132280 U 10m A 320mW

ASEP B.V. II 3 G ATEX EEx nA II T3 U


=WNCH+ECP5-300R9 Resistor in clamp 120 Ohm Ex 3 G nA A1065791
[EX] MF25 120R-Multicomp CRT-D1167129 A

ASEP B.V. II 3 G Ex nA nC II T 3
[EX] Epsilon Certified Safety controller IFM and Connector EX II 3
=WNCH+ECP5-300U0 A1066396
G n II T3
[EX] ECOMAT100 CR7020 EX II 3 G n II T3 EPSILON07ATEX2224X A

ASEP B.V. II 3 G Ex nA II
=WNCH+ECP5-302U5 Electronic Signal converter to 5V EEx n A1066385
[EX] AP00947-ASEP AP EPSILON07ATEX2239U A

ASEP B.V. II 3 G Ex nA II
=WNCH+ECP5-302U6 Electronic Signal converter to 5V EEx n A1066385
[EX] AP00947-ASEP AP EPSILON07ATEX2239U A

ASEP B.V. II 3 G Ex nA II
=WNCH+ECP5-302U7 Electronic Signal converter to 5V EEx n A1066385
[EX] AP00947-ASEP AP EPSILON07ATEX2239U A

ASEP B.V. II 3 G Ex nA II
=WNCH+ECP5-302U8 Electronic Signal converter to 5V EEx n A1066385
[EX] AP00947-ASEP AP EPSILON07ATEX2239U A

Wago Ex II 3 GD EEx nA nC II T4 24 VDC


=WNCH+ECP5-304K0 Electronic Terminal Relay 24VDC EEx nC A1029768
859-304 02 ATEX 132280 U 10m A 320mW

Wago Ex II 3 GD EEx nA nC II T4 24 VDC


=WNCH+ECP5-304K1 Electronic Terminal Relay 24VDC EEx nC A1029768
859-304 02 ATEX 132280 U 10m A 320mW

ASEP B.V. II 3G Ex nA II T3
=WNCH+ECP5-SKTC2 Mil Receptacle 10P Shell size 12 EEx nA (II 3G Ex nA II T3) A1083957
[EX] 62LC-12E12-10SN(771)-Amphenol EPSILON07ATEX2240X A

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +ECP20/1

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = WNCH + ECP5 - 2500
0 1 2 3 4 5 6 7 8 9

National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar

Winch

ECP20 = BOX EEX-E 300X200X150mm


WITH 3 COLOUR LIGHTS
A1100659

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+ECP5/2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 30

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = WNCH + ECP20 - 1
0 1 2 3 4 5 6 7 8 9

TERMINAL STRIP NUMBERING CONNECTORS

=WNCH+ECP20-X202 = TERMINAL STRIP X202 JUNCTION BOX ECP20


=WNCH+ECP20-X204 = TERMINAL STRIP X204 JUNCTION BOX JB20

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 250

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 15.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminal Strips & Connectors = WNCH + ECP20 - 30
0 1 2 3 4 5 6 7 8 9

=WNCH+

=WNCH+
PLG62 PLG61
Wellhead A B C D E Green Light A B C
Monitor A1068676
A1068677 A1082717
A1082718

W255 1 2 3 4 5 W253 1 2 3
+/21.9 +/21.10

PLG40 1
+ECP20

X202 1 2 3 3 PE 4 5 6 6 6 -250W8
reel empty
A0016294
+/21.11

W254 BK
+/21.11

PE

BK RD WH/RD RD
-250U2 + - J4 J6 J5 J7 GREEN
24V 1A
Exn -200U1 -250U8
LIGHT Earth clamp
A1105891
A0017613
+ - FLASHING
CONTROLLER RED +/21.11
RD A1101219
OG GN

J3 J1 J2
BLUE
BK BK BK
7+ 9- 1+ 2-
A1101673 24V
9175/10-12-11K
10+ 11- RD RD RD EARTH
-250A3 REEL
-250H4 -250H5 -250H6
RED BLUE GREEN
A1100637 A1101217 A1101216
X204 1 2

+ W250 1 2 3 W252 GN/YE W251 1 2


+/21.9 +/21.9 +/21.10

-VE
-250Z3
12Vdc
2+(I/S) A1100644
Note: Coax cable maximum lenght is 18 ft
1 2 3 4 +/21.10
A1098756
SKT40
PE

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
30 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : WHM System = WNCH + ECP20 - 250
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=WNCH-W255

=WNCH-W250

CABLE NAME

CABLE NAME

=WNCH-W255

=WNCH-W253

=WNCH-W252
=WNCH+ECP20-X202
TERMINAL STRIP X202 JUNCTION BOX ECP20

RADOX 5x1,5 mm²

RADOX 5x1,5 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE

RADOX 5x1,5 mm²

RADOX 3x1,5 mm²

ZH 1x6 mm²
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

=WNCH+ECP20-250U2 + 1 =WNCH+-PLG62 A 1 =WNCH+ECP20/250.2

=WNCH+ECP20-250U2 - 2 =WNCH+-PLG62 B 2 =WNCH+ECP20/250.2

1 =WNCH+-SKT40 1 3 =WNCH+ECP20/250.2

3 =WNCH+-PLG62

3 =WNCH+-SKT40 4 3 =WNCH+ECP20/250.2

2 =WNCH+-SKT40

4 =WNCH+-PLG61 A 1 =WNCH+ECP20/250.4

=WNCH+ECP20-250H4 BK 5 =WNCH+-PLG61 B 2 =WNCH+ECP20/250.4

=WNCH+ECP20-200U1

=WNCH+ECP20-200U1 J6 6 =WNCH+-PLG61 C 3 =WNCH+ECP20/250.4

=WNCH+ECP20-200U1 J5 6 =WNCH+ECP20/250.4

=WNCH+ECP20-200U1 J7 6 =WNCH+ECP20/250.4

5 =WNCH+-PLG62 E PE =WNCH+-PE GN/YE =WNCH+ECP20/250.3

4 =WNCH+-PLG62

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
250 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1101

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =WNCH+ECP20#-X202 TERMINAL STRIP X202 JUNCTION = WNCH + ECP20 - 1100
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

CABLE NAME

CABLE NAME

=WNCH-W251
=WNCH+ECP20-X204
TERMINAL STRIP X204 JUNCTION BOX JB20

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE

RADOX 2x1,5 mm²


FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

=WNCH+ECP20-250A3 10+ 1 =WNCH+-250Z3 2+(I/S) 1 =WNCH+ECP20/250.3

=WNCH+ECP20-250A3 11- 2 =WNCH+-250Z3 -VE 2 =WNCH+ECP20/250.4

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =WNCH+ECP20#-X204 TERMINAL STRIP X204 JUNCTION = WNCH + ECP20 - 1101
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN

=WNCH+ECP20-250A3 1 ISOLATOR NOV ASEP Elmar A1101673 =WNCH+ECP20/250 3

=WNCH+ECP20-250H4 1 LED MODULE ASEP B.V. A1100637 =WNCH+ECP20/250 4

=WNCH+ECP20-250H6 1 LED MODULE ASEP B.V. A1101216 =WNCH+ECP20/250 6

=WNCH+ECP20-250H5 1 LED MODULE ASEP B.V. A1101217 =WNCH+ECP20/250 5

=WNCH+ECP20-200U1 1 BLINKING MODULE ASEP B.V. A1101219 =WNCH+ECP20/250 4

=WNCH+ECP20-250U2 1 DC/DC Converter NOV ASEP Elmar A1105891 =WNCH+ECP20/250 3

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = WNCH + ECP20 - 1500
0 1 2 3 4 5 6 7 8 9

Hazardous area schedule


CODE SERIAL SPECIFICATIONS MANUFAC. / TYPE NUMBER PROT. TYPE / CERTIFICATE VOLTAGE / CURRENT POWER A. NUMBER

ASEP B.V. Ex II 3G ATEX EEx nA IIB T4 X


=WNCH+ECP20-200U1 Intelli-Flash Flasher A1101219
650201 A

NOV ASEP Elmar Ex II 3G Ex nA IIB T4 X


=WNCH+ECP20-250U2 DC/DC Converter 12-->24VDC 1A Exn certified A1105891
MINI-PS-12-24DC/24DC/1 Exn A

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +EJB13/1

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = WNCH + ECP20 - 2500
0 1 2 3 4 5 6 7 8 9

National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar

Winch

EJB 100x100x60 SS ATX ASSY MEASUREHEAD


8501035839/1
EJB13 MEASUREHEAD ATX

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+ECP20/2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 30

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = WNCH + EJB13 - 1
0 1 2 3 4 5 6 7 8 9

TERMINAL STRIP NUMBERING CONNECTORS

=WNCH+EJB13-X132 = TERMINAL STRIP X132 JUNCTION BOX EJB13 =WNCH+EJB13-PLG28 = PLG28 EJB13 Measuringhead

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 200

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 15.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminal Strips & Connectors = WNCH + EJB13 - 30
0 1 2 3 4 5 6 7 8 9

+-EJB13
8501035839

X132 1 2 3 4
+/21.2
A1079466
A1068697 A B C D
PLG28
EEx e EEx e

SKT28 A B C D
A1068696
W154 1 2 W155 1 2
A1089990
+/21.1 +/21.2
A1079465
+/21.2

MEA X54 + 55 + 18
+ECP5/303.6
=WNCH+ECP5

13 13

-200S1 -200S2 JB13- 1


A1025975 A1025975
+ECP5/303.6
14 +ECP5/303.7
14

Measurehead Measurehead
Left Right

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
30 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller = WNCH + EJB13 - 200
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=WNCH-W155

=WNCH-W154

CABLE NAME

CABLE NAME
=WNCH+EJB13-X132
TERMINAL STRIP X132 JUNCTION BOX EJB13

Molded-2 2x.. mm²

Molded-2 2x.. mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Measurehead Left 1 =WNCH+-200S1 13 1 =WNCH+EJB13-PLG28 A =WNCH+EJB13/200.1

= 2 =WNCH+-200S1 14 2 =WNCH+EJB13-PLG28 B =WNCH+EJB13/200.1

Measurehead Right 1 =WNCH+-200S2 13 3 =WNCH+EJB13-PLG28 C =WNCH+EJB13/200.2

= 2 =WNCH+-200S2 14 4 =WNCH+EJB13-PLG28 D =WNCH+EJB13/200.2

= PE =WNCH+ECP5/303.7

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
200 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =WNCH+EJB13#-X132 TERMINAL STRIP X132 JUNCTION = WNCH + EJB13 - 1100
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN

=WNCH+EJB13-PLG28 1 PLUG 19P NOV ASEP Elmar A1068697 =WNCH+EJB13/200 3

=WNCH+EJB13-PLG28 1 DUST CAP NOV ASEP Elmar A1079466 =WNCH+EJB13/200 3

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = WNCH + EJB13 - 1500
0 1 2 3 4 5 6 7 8 9

Hazardous area schedule


CODE SERIAL SPECIFICATIONS MANUFAC. / TYPE NUMBER PROT. TYPE / CERTIFICATE VOLTAGE / CURRENT POWER A. NUMBER

ASEP B.V. II 3 G Ex nA II T3
=WNCH+EJB13-PLG28 EX Cable connecting plug,19P, Shell size 22 (DS series) A1068697
[EX] DS-3102A-22-14P (Ex nA)-Amphenol EPSILON07ATEX2240X A

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE =INF+/2600

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = WNCH + EJB13 - 2500
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-102H5


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
=WNCH+EJB13/2500 PREVIOUS PAGE AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2601

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2600
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-102H8


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2600 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2602

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2601
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-102H9


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2601 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2603

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2602
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-200S1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2602 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2604

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2603
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-200S2


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2603 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2605

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2604
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-210U1-P10


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2604 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2606

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2605
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-210U3-P11


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2605 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2607

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2606
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-210U5-P12


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2606 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2608

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2607
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-210U6-P13


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2607 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2609

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2608
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-210U9-P14


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2608 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2610

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2609
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-250Z3


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2609 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2611

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2610
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-301S1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2610 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2612

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2611
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-302Y3


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2611 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2613

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2612
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-303Y1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2612 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2614

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2613
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-304Y5


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2613 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2615

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2614
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-304Y6


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2614 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2616

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2615
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-304Y7


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2615 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2617

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2616
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-304Y8


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2616 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2618

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2617
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-305Y4


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2617 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2619

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2618
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-ECP5


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2618 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2620

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2619
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-EJB13


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2619 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2621

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2620
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-PLG3


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2620 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2622

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2621
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-PLG4


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2621 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2623

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2622
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-PLG50


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2622 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2624

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2623
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-PLG51


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2623 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2625

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2624
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-PLG52


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2624 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2626

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2625
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-PLG53


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2625 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2627

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2626
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-PLG56


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2626 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2628

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2627
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-PLG61


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2627 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2629

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2628
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-PLG62


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2628 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2630

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2629
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-PLG71


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2629 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2631

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2630
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-SKT28


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2630 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2632

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2631
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+-SKT40


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2631 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2633

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2632
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-300F0


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2632 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2634

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2633
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-300F1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2633 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2635

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2634
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-300F2


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2634 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2636

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2635
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-300K4


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2635 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2637

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2636
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-300R9


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2636 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2638

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2637
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-300U0


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2637 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2639

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2638
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-302U5


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2638 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2640

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2639
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-302U6


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2639 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2641

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2640
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-302U7


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2640 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2642

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2641
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-302U8


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2641 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2643

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2642
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-304K0


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2642 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2644

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2643
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-304K1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2643 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2645

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2644
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP5-SKTC2


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2644 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2646

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2645
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP20-200U1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2645 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2647

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2646
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+ECP20-250U2


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2646 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2648

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2647
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =WNCH+EJB13-PLG28


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus

complete and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2647 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE

B --
H.Tuytelaars
G.Martina M. KRAUS RELEASED TITLE : WINCH DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12-09-2011 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033765
Format: A4 PAGE MOD 12.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2648

You might also like