You are on page 1of 307

DESIGN FOR COLUMN

TOP 1 C1
(2 GIRDER CONNECTIONS)

Given
Pd1 = 1357.088 kN PD PU MY MZ
Pu1 = 1409.079 kN -1309.59 -1368.37 -0.009 -0.032 -1118.1 -1749.5 4.41 6.81
Lu = 3800 mm 1357.088 1409.079 0.009 0.032 812.972 1766.7 4.1 6.89
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 0.9631028494

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 3000 1.60E+09 5.33E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 533333.33333 MY 0.009 0.009
1357.088 1409.079
B2 266666.66667 MZ 0.032 0.032
USE 1357.088 1409.079 0.041 0.041

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.8236762
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 1.8237 cu.mm B2

B1
k = 0.84118 k1 = 0.841184
k2 = 0.941184
C1
0.4 Ec Ig
E1 = = 6.33702E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 6121.184692 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.841184 Cm = 1 ok!
Pc = 6121.2 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.4428546057139 > 1


≤ 34-12(m1/m2) δ
r USE, 1.442854606
r = 105

30.44284 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 51.84395119 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 35931.5145 KN-mm = 35.9315145 KN-m

Moment to be use: 35.9315145 KN-m

Column Design:
CC= 58

Pu = 1409.079 kN
Mu = 51.843951187 kN.m
e = Mu/Pu = 36.79279 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 2167.814

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.632016
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.066439
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C1
(2 GIRDER CONNECTIONS)

Given
Pd1 = 1357.088 kN PD PU MY MZ
Pu1 = 1362.828 kN -1309.587 -1322.11 -0.007 -0.031 -1118.1 -1452.1 3.88 6.55
Lu = 3800 mm 1357.088 1362.828 -0.007 0.031 812.972 1469.34 3.6 6.59
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 0.9957881699

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 3000 1.60E+09 5.33E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 533333.33333 MY 0.007 0.007
1357.088 1362.828
B2 266666.66667 MZ 0.031 0.031
USE 1357.088 1362.828 0.038 0.038

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.8236762
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 1.8237 cu.mm B2

B1
k = 0.84118 k1 = 0.841184
k2 = 0.941184
C1
0.4 Ec Ig
E1 = = 6.23323E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 6020.9371376 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.841184 Cm = 0.2 not ok!
Pc = 6020.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.5728997265609 < 1


≤ 34-12(m1/m2) δ
r USE, 1
r = 105

30.44284 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 34.752114 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 34752.114 KN-mm = 34.752114 KN-m

Moment to be use: 34.752114 KN-m

Column Design:
CC= 58

Pu = 1362.828 kN
Mu = 0.038 kN.m
e = Mu/Pu = 0.027883 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 2096.658

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.611271
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 4.87E-05
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln 3700 mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C1
(2 GIRDER CONNECTIONS)

Given
Pd1 = 1357.088 kN PD PU MY MZ
Pu1 = 1324.634 kN -1309.59 -1238.92 -0.007 4.518 ### ### 3.87 6.56
Lu = 3800 mm 1357.088 1324.634 0.007 4.584 813 ### 3.65 6.62
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.0245003526

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 3000 1.60E+09 5.33E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 533333.33333 MY 0.007 0.007
1357.088 1324.634
B2 266666.66667 MZ 4.518 4.584
USE 1357.088 1324.634 4.525 4.591

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.8236762
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 1.8237 cu.mm B2

B1
k = 0.84118 k1 = 0.841184
k2 = 0.941184
C1
0.4 Ec Ig
E1 = = 6.14483E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 5935.5460698 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.841184 Cm = 0.2057503812 not ok!
Pc = 5935.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.5694433228 < 1


≤ 34-12(m1/m2) δ
r USE, 1
r = 105

30.44284 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 33.77817 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 33778.167 KN-mm = 33.778167 KN-m

Moment to be use: 33.778167 KN-m

Column Design:
CC= 58

Pu = 1324.634 kN
Mu = 4.591 kN.m
e = Mu/Pu = 3.465863 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 2037.898

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.594139
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.005883
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C1
(2 GIRDER CONNECTIONS)

Given
Pd1 = 1357.088 kN PD PU MY MZ
Pu1 = 1200.254 kN -1309.59 -1227.98 -68.078 -0.381 ### ### 4.41 6.81
Lu = 3800 mm 1357.088 1200.254 68.225 0.37 813 ### 4.1 6.89
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.1306673421

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 3000 1.60E+09 5.33E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 533333.33333 MY 68.078 68.225
1357.088 1200.254
B2 266666.66667 MZ 0.381 0.37
USE 1357.088 1200.254 68.459 68.595

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.823676
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 1.8237 cu.mm B2

B1
k = 0.84118 k1 = 0.841184
k2 = 0.941184
C1
0.4 Ec Ig
E1 = = 5.83865E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 5639.7894094 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.841184 Cm = 0.9992069393 ok!
Pc = 5639.8 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.3950700412 > 1
≤ 34-12(m1/m2) δ
r USE, 1.39507

r = 105

30.44284 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 95.69483 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 30606.477 KN-mm = 30.606477 KN-m

Moment to be use: 68.595 KN-m

Column Design:
CC= 58

Pu = 1200.254 kN
Mu = 95.694829474 kN.m
e = Mu/Pu = 79.72882 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 1846.545

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.012 0.01 0.01 Pn
Kn = = 0.538351
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.012 - 0.01 0.012 - ρg Rn = Pne
= 0.122635
fc' Ag h

ρg = 0.0106285714 As = ρgAg
As = 1302 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.47890127388535
20 mm 4.14649681528662 16 8
25 mm 2.65375796178344
28 mm 2.11555959963603
32 mm 1.61972531847134
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C1
(2 GIRDER CONNECTIONS)

Given
Pd1 = 1357.088 kN PD PU MY MZ
Pu1 = 838.194 kN -1309.59 -876.097 -68.076 -0.373 ### ### 3.88 6.55
Lu = 3800 mm 1357.088 838.194 68.223 0.362 813 ### 3.6 6.59
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.6190619355

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 3000 1.60E+09 5.33E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 533333.33333 MY 68.076 68.223
1357.088 838.194
B2 266666.66667 MZ 0.373 0.362
USE 1357.088 838.194 68.449 68.585

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.823676
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 1.8237 cu.mm B2

B1
k = 0.84118 k1 = 0.841184
k2 = 0.941184
C1
0.4 Ec Ig
E1 = = 4.74987E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 4588.0988715 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.841184 Cm = 0.2007931764 not ok!
Pc = 4588.1 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.5288102334 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.44284 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 68.585 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 21373.947 KN-mm = 21.373947 KN-m

Moment to be use: 68.585 KN-m

Column Design:
CC= 58

Pu = 838.194 kN
Mu = 68.585 kN.m
e = Mu/Pu = 81.82473 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 1289.529

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.375956
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.087893
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C1
(2 GIRDER CONNECTIONS)

Given
Pd1 = 1357.088 kN PD PU MY MZ
Pu1 = 1320.858 kN -1309.59 -839.163 6.293 -0.022 ### ### 3.87 6.56
Lu = 3800 mm 1357.088 1320.858 6.314 0.03 813 ### 3.65 6.62
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.0274291408

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 3000 1.60E+09 5.33E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 533333.33333 MY 6.293 6.314
1357.088 1320.858
B2 266666.66667 MZ 0.022 0.03
USE 1357.088 1320.858 6.315 6.344

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.823676
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 1.8237 cu.mm B2

B1
k = 0.84118 k1 = 0.841184
k2 = 0.941184
C1
0.4 Ec Ig
E1 = = 6.13595E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 5926.9716852 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.841184 Cm = 0.2018284994 not ok!
Pc = 5927.0 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.569103874 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.44284 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 33.68188 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 33681.879 KN-mm = 33.681879 KN-m

Moment to be use: 33.681879 KN-m

Column Design:
CC= 58

Pu = 1320.858 kN
Mu = 6.344 kN.m
e = Mu/Pu = 4.802939 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 2032.089

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.592446
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.00813
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C1
(2 GIRDER CONNECTIONS)

Given
Pd1 = 1357.088 kN PD PU MY MZ
Pu1 = 1253.005 kN -1309.59 -1175.23 -0.076 -67.888 ### ### 4.41 6.81
Lu = 3800 mm 1357.088 1253.005 0.065 67.969 813 ### 4.1 6.89
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.0830667076

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 3000 1.60E+09 5.33E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 533333.33333 MY 0.076 0.065
1357.088 1253.005
B2 266666.66667 MZ 67.888 67.969
USE 1357.088 1253.005 67.964 68.034

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.823676
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 1.8237 cu.mm B2

B1
k = 0.84118 k1 = 0.841184
k2 = 0.941184
C1
0.4 Ec Ig
E1 = = 5.97207E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 5768.665529 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.841184 Cm = 0.2004115589 not ok!
Pc = 5768.7 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.5630723782 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.44284 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 68.034 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 31951.6275 KN-mm = 31.9516275 KN-m

Moment to be use: 68.034 KN-m

Column Design:
CC= 58

Pu = 1253.005 kN
Mu = 68.034 kN.m
e = Mu/Pu = 54.29667 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 1927.7

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.562012
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.087187
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C1
(2 GIRDER CONNECTIONS)

Given
Pd1 = 1357.088 kN PD PU MY MZ
Pu1 = 890.945 kN -1309.59 -823.346 -0.074 -67.88 ### ### 3.88 6.55
Lu = 3800 mm 1357.088 890.945 0.062 67.961 813 ### 3.6 6.59
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.5232006465

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 3000 1.60E+09 5.33E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 533333.33333 MY 0.074 0.062
1357.088 890.945
B2 266666.66667 MZ 67.88 67.961
USE 1357.088 890.945 67.954 68.023

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.823676
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 1.8237 cu.mm B2

B1
k = 0.84118 k1 = 0.841184
k2 = 0.941184
C1
0.4 Ec Ig
E1 = = 4.93033E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 4762.4096512 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.841184 Cm = 0.2004057451 not ok!
Pc = 4762.4 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.5329340967 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.44284 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 68.023 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 22719.0975 KN-mm = 22.7190975 KN-m

Moment to be use: 68.023 KN-m

Column Design:
CC= 58

Pu = 890.945 kN
Mu = 68.023 kN.m
e = Mu/Pu = 76.34927 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 1370.685

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.399617
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.087173
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C1
(2 GIRDER CONNECTIONS)

Given
Pd1 = 1357.088 kN PD PU MY MZ
Pu1 = 1324.634 kN -1309.59 -842.939 -0.003 4.527 ### ### 3.87 6.56
Lu = 3800 mm 1357.088 1324.634 0.007 4.584 813 ### 3.65 6.62
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.0245003526

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 3000 1.60E+09 5.33E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 533333.33333 MY 0.003 0.007
1357.088 1324.634
B2 266666.66667 MZ 4.527 4.584
USE 1357.088 1324.634 4.53 4.591

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.823676
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 1.8237 cu.mm B2

B1
k = 0.84118 k1 = 0.841184
k2 = 0.941184
C1
0.4 Ec Ig
E1 = = 6.14483E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 5935.5460698 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.841184 Cm = 0.2053147462 not ok!
Pc = 5935.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.5694433228 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.44284 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 33.77817 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 33778.167 KN-mm = 33.778167 KN-m

Moment to be use: 33.778167 KN-m

Column Design:
CC= 58

Pu = 1324.634 kN
Mu = 4.591 kN.m
e = Mu/Pu = 3.465863 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 2037.898

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.594139
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.005883
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C2
1ST FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 1365.443 kN
Pu1 = 1418.333 kN PD PU MY MZ
Lu = 3800 mm -1317.943 -1377.62 -0.009 -0.032 -1547.2 -1773.2 5.56 6.81
f'c = 28 Mpa 1365.443 1418.333 0.009 0.032 1125.23 1790.43 5.26 6.89
Ec = 24870.062324 Mpa
βdns = 0.9627097445

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 312630.20833 fixed 1.0 MU Non-Sway (Beam No. )
C2 416840.27778 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 0.009 0.009
1365.443 1418.333
B3 266666.66667 MZ 0.032 0.032
USE 1365.443 1418.333 0.041 0.041

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.39430894
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm
B3 B2
k = 0.81972 k1 = 0.8197154
k2 = 0.9197154 B1
0.4 Ec Ig C1
E1 = = 6.33828E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 6447.3022627 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.819715 Cm = 1 ok!
Pc = 6447.3 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.4150639030042 > 1


≤ 34-12(m1/m2) δ
r USE, 1.415063903

r = 105
29.66589 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 51.17931168 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 36167.4915 KN-mm = 36.1674915 KN-m

Moment to be use: 36.1674915 KN-m

Column Design:
CC= 58

Pu = 1418.333 kN
Mu = 51.179311684 kN.m
e = Mu/Pu = 36.08413 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 2182.051

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.636166
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.065587
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.6666666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln 3700 mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C2
1ST FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 1365.443 kN
Pu1 = 1371.298 kN PD PU MY MZ
Lu = 3800 mm -1317.943 -1330.58 -0.007 -0.031 -1547.2 -1759.9 4.91 6.81
f'c = 28 Mpa 1365.443 1371.298 -0.007 0.031 1125.23 1777.08 4.61 6.89
Ec = 24870.062324 Mpa
βdns = 0.9957303227

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 312630.20833 fixed 1.0 MU Non-Sway (Beam No. )
C2 416840.27778 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 0.007 0.007
1365.443 1371.298
B3 266666.66667 MZ 0.031 0.031
USE 1365.443 1371.298 0.038 0.038

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.39430894
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm
B3 B2
k = 0.81972 k1 = 0.8197154
k2 = 0.9197154 B1
0.4 Ec Ig C1
E1 = = 6.23341E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 6340.6277054 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.819715 Cm = 1 ok!
Pc = 6340.6 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.4052092164073 > 1


≤ 34-12(m1/m2) δ
r USE, 1.405209216

r = 105
29.66589 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 49.137495 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 34968.099 KN-mm = 34.968099 KN-m

Moment to be use: 34.968099 KN-m

Column Design:
CC= 58

Pu = 1371.298 kN
Mu = 49.137494995 kN.m
e = Mu/Pu = 35.83284 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 2109.689

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.61507
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.062971
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = o

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.666666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln 3700 mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C2
1ST FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 1365.443 kN
Pu1 = 1333.455 kN PD PU MY MZ
Lu = 3800 mm -1317.943 -1292.74 -0.007 4.518 ### ### 4.95 6.55
f'c = 28 Mpa 1365.443 1333.455 0.007 4.584 1125 ### 4.67 6.59
Ec = 24870.062324 Mpa
βdns = 1.023988811

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 312630.20833 fixed 1.0 MU Non-Sway (Beam No. )
C2 416840.27778 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 0.007 0.007
1365.443 1333.455
B3 266666.66667 MZ 4.518 4.584
USE 1365.443 1333.455 4.525 4.591

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.39430894
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm
B3 B2
k = 0.81972 k1 = 0.8197154
k2 = 0.9197154 B1
0.4 Ec Ig C1
E1 = = 6.14638E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 6252.1012505 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.819715 Cm = 0.9942496188 ok!
Pc = 6252.1 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.389344044 > 1


≤ 34-12(m1/m2) δ
r USE, 1.389344

r = 105
29.66589 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 47.24201 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 34003.1025 KN-mm = 34.0031025 KN-m

Moment to be use: 34.0031025 KN-m

Column Design:
CC= 58

Pu = 1333.455 kN
Mu = 47.242007935 kN.m
e = Mu/Pu = 35.42827 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 2051.469

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.598096
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.060541
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.6666666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln 3700 mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C2
1ST FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 1365.443 kN
Pu1 = 1231.498 kN PD PU MY MZ
Lu = 3800 mm -1317.94 -1212.37 -68.237 -0.115 ### ### 60 -33
f'c = 28 Mpa 1365.443 1231.498 68.385 0.104 1125 ### 59 -33
Ec = 24870.062324 Mpa
βdns = 1.1087659095

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 312630.20833 fixed 1.0 MU Non-Sway (Beam No. )
C2 416840.27778 MU1
Pd (kN) Pu (kN)
B1 379687.5 (kN.m)
B2 400000 MY 68.237
1365.443 1231.498
B3 266666.66667 MZ 0.115
USE 1365.443 1231.498 68.352

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm
B3 B2
k = 0.81972 k1 = 0.819715
k2 = 0.919715 B1
0.4 Ec Ig C1
E1 = = 5.89929E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 6000.7528192 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.819715 Cm = 0.9991998715 ok!
Pc = 6000.8 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.37561087456 > 1


≤ 34-12(m1/m2) δ
r USE, 1.375611

r = 105

29.66589 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 94.214213 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 31403.199 KN-mm = 31.403199 KN-m

Moment to be use: 68.489 KN-m

Column Design:

Pu = 1231.498 kN
Mu = 94.214213188 kN.m
e = Mu/Pu = 76.50375 mm 350
234
γ = = 0.668571
350
Pn = Pu/Ф = 1894.612

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.552365
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.120737
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
C2 TOP 2 C2
1ST FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 1365.443 kN
Pu1 = 866.993 kN PD PU MY MZ
Lu = 3800 mm -1317.94 -858.041 -68.235 -0.107 -1547.2 -1052.9 59 -33
f'c = 28 Mpa 1365.443 866.993 68.382 0.096 1125.23 1059.51 59 -33
Ec = 24870.062324 Mpa
βdns = 1.5749181366

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 312630.20833 fixed 1.0 MU Non-Sway (Beam No. )
MU2 C2 416840.27778 MU1 MU2
Pd (kN) Pu (kN)
(kN.m) B1 379687.5 (kN.m) (kN.m)
68.385 B2 400000 MY 68.235 68.382
1365.443 866.993
0.104 B3 266666.66667 MZ 0.107 0.096
68.489 USE 1365.443 866.993 68.342 68.478

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm
B3 B2
k = 0.81972 k1 = 0.819715
k2 = 0.919715 B1
0.4 Ec Ig C1
E1 = = 4.8313E+12N-mm^2
1 + Bdns

π^2EI
Pc = = 4914.4020529 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.819715 Cm = 0.9992055843 ok!
Pc = 4914.4 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.3065355199348 > 1


≤ 34-12(m1/m2) δ
r USE, 1.30653552

r = 105

29.66589 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 89.46893933 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 22108.3215 KN-mm = 22.1083215 KN-m

Moment to be use: 68.478 KN-m

Column Design:
CC= 58 CC= 58

Pu = 866.993 kN
Mu = 89.468939334 kN.m
mm e = Mu/Pu = 103.1945 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 1333.835

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.388873
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.114656
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C2
1ST FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 1365.443 kN
Pu1 = 1331.186 kN PD PU MY MZ
Lu = 3800 mm -1317.94 -846.393 6.293 -0.022 -1547.2 -1052.9 59 -33
f'c = 28 Mpa 1365.443 1331.186 6.314 0.03 1125.23 1039.73 59 -33
Ec = 24870.062324 Mpa
βdns = 1.0257341949

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 312630.20833 fixed 1.0 MU Non-Sway (Beam No. )
C2 416840.27778 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 6.293 6.314
1365.443 1331.186
B3 266666.66667 MZ 0.022 0.03
USE 1365.443 1331.186 6.315 6.344

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm
B3 B2
k = 0.81972 k1 = 0.819715
k2 = 0.919715 B1
0.4 Ec Ig C1
E1 = = 6.14109E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 6246.7144052 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.819715 Cm = 0.9981715006 ok!
Pc = 6246.7 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.3943585706967 > 1


≤ 34-12(m1/m2) δ
r USE, 1.394358571

r = 105

29.66589 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 47.33184051 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 33945.243 KN-mm = 33.945243 KN-m

Moment to be use: 33.945243 KN-m

Column Design:
CC= 40

Pu = 1331.186 kN
Mu = 47.331840511 kN.m
e = Mu/Pu = 35.55614 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 2047.978

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.597078
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.060657
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C2
1ST FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 1365.443 kN
Pu1 = 1266.95 kN PD PU MY MZ
Lu = 3800 mm -1317.94 -1176.91 -0.109 -67.834 ### ### 60 -33
f'c = 28 Mpa 1365.443 1266.95 0.097 67.914 ### ### 59 -33
Ec = 24870.062324 Mpa
βdns = 1.0777402423

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 312630.20833 fixed 1.0 MU Non-Sway (Beam No. )
C2 416840.27778 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 0.109 0.097
1365.443 1266.95
B3 266666.66667 MZ 67.834 67.914
USE 1365.443 1266.95 67.943 68.011

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.394309
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm
B3 B2
k = 0.81972 k1 = 0.819715
k2 = 0.919715 B1
0.4 Ec Ig C1
E1 = = 5.98738E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 6090.3585149 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.819715 Cm = 0.9996000647 ok!
Pc = 6090.4 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.3832755542 > 1
≤ 34-12(m1/m2) δ
r USE, 1.383276

r = 105

29.66589 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 94.07795 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 32307.225 KN-mm = 32.307225 KN-m

Moment to be use: 68.011 KN-m

Column Design:
CC= 58

Pu = 1266.95 kN
Mu = 94.077953718 kN.m
e = Mu/Pu = 74.25546 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 1949.154

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.013 0.011629 0.011 Pn
Kn = = 0.568266
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.013 - 0.011 0.013 - ρg Rn = Pne
= 0.120563
fc' Ag h

ρg = 0.0116285714 As = ρgAg
As = 1424.5 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 7.08847531847134
20 mm 4.53662420382166 16 8
25 mm 2.90343949044586
28 mm 2.31460418562329
32 mm 1.77211882961783
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C2
1ST FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 1365.443 kN
Pu1 = 902.446 kN PD PU MY MZ
Lu = 3800 mm -1317.94 -822.589 -0.106 -67.826 ### ### 59 -33
f'c = 28 Mpa 1365.443 902.446 0.095 67.906 ### ### 59 -33
Ec = 24870.062324 Mpa
βdns = 1.513046764

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 312630.20833 fixed 1.0 MU Non-Sway (Beam No. )
C2 416840.27778 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 0.106 0.095
1365.443 902.446
B3 266666.66667 MZ 67.826 67.906
USE 1365.443 902.446 67.932 68.001

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.394309
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm
B3 B2
k = 0.81972 k1 = 0.819715
k2 = 0.919715 B1
0.4 Ec Ig C1
E1 = = 4.95025E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 5035.3949467 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.819715 Cm = 0.9995941236 ok!
Pc = 5035.4 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.3134592127 > 1
≤ 34-12(m1/m2) δ
r USE, 1.313459

r = 105

29.66589 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 89.31654 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 23012.373 KN-mm = 23.012373 KN-m

Moment to be use: 68.001 KN-m

Column Design:
CC= 58

Pu = 902.446 kN
Mu = 89.316539923 kN.m
e = Mu/Pu = 98.97162 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 1388.378

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.404775
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.114461
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C2
1ST FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 1365.443 kN
Pu1 = 1333.455 kN PD PU MY MZ
Lu = 3800 mm -1317.94 -848.662 -0.003 4.527 ### ### 59 -33
f'c = 28 Mpa 1365.443 1333.455 0.007 4.584 ### ### 59 -33
Ec = 24870.062324 Mpa
βdns = 1.023988811

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 312630.20833 fixed 1.0 MU Non-Sway (Beam No. )
C2 416840.27778 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 0.003 0.007
1365.443 1333.455
B3 266666.66667 MZ 4.527 4.584
USE 1365.443 1333.455 4.53 4.591

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.394309
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm
B3 B2
k = 0.81972 k1 = 0.819715
k2 = 0.919715 B1
0.4 Ec Ig C1
E1 = = 6.14638E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 6252.1012505 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.819715 Cm = 0.9946852538 ok!
Pc = 6252.1 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.3899527913 > 1
≤ 34-12(m1/m2) δ
r USE, 1.389953

r = 105

29.66589 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 47.26271 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 34003.1025 KN-mm = 34.0031025 KN-m

Moment to be use: 34.0031025 KN-m

Column Design:
CC= 58

Pu = 1333.455 kN
Mu = 47.262707233 kN.m
e = Mu/Pu = 35.4438 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 2051.469

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.598096
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.060568
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C3
1ST FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 1331.938 kN
Pu1 = 1388.562 kN PD PU MY MZ
Lu = 3775 mm -1284.44 -1347.85 -0.009 -0.032 -431 ### 1.56 -0.2
f'c = 28 Mpa 1331.938 1388.562 0.009 0.032 313 596 1.55 -0.3
Ec = 24870.062324 Mpa
βdns = 0.9592211223

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 300 300 4000 6.75E+08 1.69E+05
Column 2 (C2) 300 300 3000 6.75E+08 2.25E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 3000 1.60E+09 5.33E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 168750 fixed 1.0 MU1
Pd (kN) Pu (kN)
C2 225000 (kN.m)
B1 379687.5 MY 0.009
1331.938 1388.562
B2 379687.5 MZ 0.032
B3 400000 USE 1331.938 1388.562 0.041
B4 533333.33333

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.465231
0.35 ΣIgbeam (1/Lbeam)
C2
0.7 ΣIgcol. (1/Lcol.) B4
ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

B3B3 B2 B1
ψm = smaller of ψA and ψB = 0.4652 cu.mm

k = 0.77326 k1 = 0.773262 B1
k2 = 0.873262

B2 C1
0.4 Ec Ig
E1 = = 3.42734E+12
N-mm^2 C1
1 + Bdns

π^2EI
Pc = = 3969.8143621 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3775 mm
Dimension = 300 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 6.75E+08 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.773262 Cm = 1 ok!
Pc = 3969.8 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.873969709 > 1


≤ 34-12(m1/m2) δ
r USE, 1.87397

r = 90

32.43403 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 62.45096 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 33325.488 KN-mm = 33.325488 KN-m

Moment to be use: 33.325488 KN-m

Column Design:

Pu = 1388.562 kN
Mu = 62.450955048 kN.m
e = Mu/Pu = 44.97527 mm 300
220
γ = = 0.733333
300
Pn = Pu/Ф = 2136.249

300 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.733333 0.7
ρg 0.029 0.027667 0.028 Pn
Kn = = 0.847718
f'cAg
0.6 - 0.7 0.6 - 0.733333
=
0.029 - 0.028 0.029 - ρg Rn = Pne
= 0.127088
fc' Ag h

ρg = 0.0276666667 As = ρgAg
As = 2490 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 12.390525477707
20 mm 7.92993630573248 20 8
25 mm 5.07515923566879
28 mm 4.04588587027168
32 mm 3.09763136942675

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 90 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 160
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 150
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 612.5 mm
2) L = b = h = 300 mm
3) L = 450 = 450 mm

Conf't zone
L = 612.5
SUMMARY
Conf't zone
ln ### mm 1 - 75 mm
Intermediate zone 5 - 150 mm
Intermediate zone
Rest @ 300 mm

L = 612.5
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 320 mm


B.) 48dt = 576 mm
C.) least dimension of column = 300 mm

Say, S = 300 mm
DESIGN FOR COLUMN
C3 TOP 1 C3
1ST FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 1331.938 kN
Pu1 = 1222.893 kN PD PU MY MZ
Lu = 3775 mm -1284.44 -1162.88 -67.441 0.044 -431 -590 1.56 -0.2
f'c = 28 Mpa 1331.938 1222.893 67.588 -0.055 313.48 596.46 1.55 -0.3
Ec = 24870.062324 Mpa
βdns = 1.0891696984

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 300 300 4000 6.75E+08 1.69E+05
Column 2 (C2) 300 300 3000 6.75E+08 2.25E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 3000 1.60E+09 5.33E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
MU2 C1 168750 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
(kN.m) C2 225000 (kN.m) (kN.m)
0.009 B1 379687.5 MY 67.441 67.588
1331.938 1222.893
0.032 B2 379687.5 MZ 0.044 0.055
0.041 B3 400000 USE 1331.938 1222.893 67.485 67.643
B4 533333.33333

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.465231
0.35 ΣIgbeam (1/Lbeam)
C2
B4 0.7 ΣIgcol. (1/Lcol.) B4
ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

B1 B3B3 B2 B1
ψm = smaller of ψA and ψB = 0.4652 cu.mm

k = 0.77326 k1 = 0.773262 B1
k2 = 0.873262

B2 C1
0.4 Ec Ig
E1 = = 3.21416E+12
N-mm^2 C1
1 + Bdns

π^2EI
Pc = = 3722.8876887 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3775 mm
Dimension = 300 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 6.75E+08 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.773262 Cm = 0.2009343169 not ok!
Pc = 3722.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.711709481255 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 90

32.43403 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 67.643 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 29349.432 KN-mm = 29.349432 KN-m

Moment to be use: 67.643 KN-m

Column Design:
CC= 40 CC= 40

Pu = 1222.893 kN
Mu = 67.643 kN.m
mm e = Mu/Pu = 55.31392 mm 300 mm
220
γ = = 0.733333
300
Pn = Pu/Ф = 1881.374

300 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.733333 0.7
ρg 0.022 0.016667 0.018 Pn
Kn = = 0.746577
f'cAg
0.6 - 0.7 0.6 - 0.733333
=
0.022 - 0.018 0.022 - ρg Rn = Pne
= 0.137654
fc' Ag h

ρg = 0.0166666667 As = ρgAg
As = 1500 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 7.46417197452229
20 mm 4.77707006369427 16 12
25 mm 3.05732484076433
28 mm 2.43728064474197
32 mm 1.86604299363057

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 57.33333 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 150
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 612.5 mm
2) L = b = h = 300 mm
3) L = 450 = 450 mm

Conf't zone
L = 612.5
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 612.5
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 300 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C3
1ST FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 1331.938 kN
Pu1 = 1196.611 kN PD PU MY MZ
Lu = 3775 mm -1284.44 -1189.16 0.054 -67.802 -431 -590 1.56 -0.2
f'c = 28 Mpa 1331.938 1196.611 -0.065 67.882 313.48 596.46 1.55 -0.3
Ec = 24870.062324 Mpa
βdns = 1.1130918903

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 300 300 4000 6.75E+08 1.69E+05
Column 2 (C2) 300 300 3000 6.75E+08 2.25E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 3000 1.60E+09 5.33E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 168750 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 225000 (kN.m) (kN.m)
B1 379687.5 MY 0.054 0.065
1331.938 1196.611
B2 379687.5 MZ 67.802 67.882
B3 400000 USE 1331.938 1196.611 67.856 67.947
B4 533333.33333

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.465231
0.35 ΣIgbeam (1/Lbeam)
C2
0.7 ΣIgcol. (1/Lcol.) B4
ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

B3B3 B2 B1
ψm = smaller of ψA and ψB = 0.4652 cu.mm

k = 0.77326 k1 = 0.773262 B1
k2 = 0.873262

B2 C1
0.4 Ec Ig
E1 = = 3.17777E+12
N-mm^2 C1
1 + Bdns

π^2EI
Pc = = 3680.741091 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3775 mm
Dimension = 300 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 6.75E+08 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.773262 Cm = 0.2005357117 not ok!
Pc = 3680.7 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.706049417102 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 90

32.43403 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 67.947 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 28718.664 KN-mm = 28.718664 KN-m

Moment to be use: 67.947 KN-m

Column Design:
CC= 40

Pu = 1196.611 kN
Mu = 67.947 kN.m
e = Mu/Pu = 56.78286 mm 300 mm
220
γ = = 0.733333
300
Pn = Pu/Ф = 1840.94

300 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.733333 0.7
ρg 0.028 0.022667 0.024 Pn
Kn = = 0.730532
f'cAg
0.6 - 0.7 0.6 - 0.733333
=
0.028 - 0.024 0.028 - ρg Rn = Pne
= 0.138272
fc' Ag h

ρg = 0.0226666667 As = ρgAg
As = 2040 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 10.1512738853503
20 mm 6.4968152866242 20 8
25 mm 4.15796178343949
28 mm 3.31470167684908
32 mm 2.53781847133758

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 90 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 160
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 150
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 612.5 mm
2) L = b = h = 300 mm
3) L = 450 = 450 mm

Conf't zone
L = 612.5
SUMMARY
Conf't zone
ln ### mm 1 - 75 mm
Intermediate zone 5 - 150 mm
Intermediate zone
Rest @ 300 mm

L = 612.5
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 320 mm


B.) 48dt = 576 mm
C.) least dimension of column = 300 mm

Say, S = 300 mm
DESIGN FOR COLUMN
TOP 2 C3
1ST FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 1331.938 kN
Pu1 = 1341.922 kN PD PU MY MZ
Lu = 3775 mm -1284.44 -1301.21 -0.007 -0.031 ### ### 1.56 -0.2
f'c = 28 Mpa 1331.938 1341.922 -0.007 0.031 313 596 1.55 -0.3
Ec = 24870.062324 Mpa
βdns = 0.9925599252

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 3000 1.60E+09 5.33E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m)
B1 379687.5 MY 0.007
1331.938 1341.922
B2 379687.5 MZ 0.031
B3 400000 USE 1331.938 1341.922 0.038
B4 533333.33333

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)
C2
0.7 ΣIgcol. (1/Lcol.) B4
ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

B3B3 B2 B1
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79309 k1 = 0.793095 B1
k2 = 0.893095

B2 C1
0.4 Ec Ig
E1 = = 6.24333E+12
N-mm^2 C1
1 + Bdns

π^2EI
Pc = = 6874.3549842 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3775 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.793095 Cm = 1 ok!
Pc = 6874.4 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.3518554813 > 1


≤ 34-12(m1/m2) δ
r USE, 1.351855

r = 105

28.51365 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 46.25916 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 34219.011 KN-mm = 34.219011 KN-m

Moment to be use: 34.219011 KN-m

Column Design:

Pu = 1341.922 kN
Mu = 46.259157585 kN.m
e = Mu/Pu = 34.47231 mm 350
270
γ = = 0.771429
350
Pn = Pu/Ф = 2064.495

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.601894
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.059282
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 612.5 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 612.5
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 612.5
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
C3 TOP 2 C3
1ST FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 1331.938 kN
Pu1 = 865.897 kN PD PU MY MZ
Lu = 3775 mm -1284.44 -816.059 -67.438 0.052 ### ### 1.56 -0.2
f'c = 28 Mpa 1331.938 865.897 67.586 -0.063 313 596 1.55 -0.3
Ec = 24870.062324 Mpa
βdns = 1.538217594

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 3000 1.60E+09 5.33E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
MU2 C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
(kN.m) C2 416840.27778 (kN.m) (kN.m)
0.007 B1 379687.5 MY 67.438 67.586
1331.938 865.897
0.031 B2 379687.5 MZ 0.052 0.063
0.038 B3 400000 USE 1331.938 865.897 67.49 67.649
B4 533333.33333

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)
C2
B4 0.7 ΣIgcol. (1/Lcol.) B4
ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

B1 B3B3 B2 B1
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79309 k1 = 0.793095 B1
k2 = 0.893095

B2 C1
0.4 Ec Ig
E1 = = 4.90116E+12
N-mm^2 C1
1 + Bdns

π^2EI
Pc = = 5396.5287632 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3775 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.793095 Cm = 0.2009401469 not ok!
Pc = 5396.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.5088665241 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.51365 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 67.649 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 22080.3735 KN-mm = 22.0803735 KN-m

Moment to be use: 67.649 KN-m

Column Design:
CC= 40 CC= 40

Pu = 865.897 kN
Mu = 67.649 kN.m
mm e = Mu/Pu = 78.12592 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1332.149

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.388382
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.086693
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 612.5 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 612.5
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 612.5
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C3
1ST FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 1331.938 kN
Pu1 = 839.616 kN PD PU MY MZ
Lu = 3775 mm -1284.44 -842.341 0.056 -67.794 ### ### 1.56 -0.2
f'c = 28 Mpa 1331.938 839.616 -0.068 67.874 313 596 1.55 -0.3
Ec = 24870.062324 Mpa
βdns = 1.5863656719

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 3000 1.60E+09 5.33E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 379687.5 MY 0.056 0.068
1331.938 839.616
B2 379687.5 MZ 67.794 67.874
B3 400000 USE 1331.938 839.616 67.85 67.942
B4 533333.33333

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)
C2
0.7 ΣIgcol. (1/Lcol.) B4
ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

B3B3 B2 B1
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79309 k1 = 0.793095 B1
k2 = 0.893095

B2 C1
0.4 Ec Ig
E1 = = 4.80992E+12
N-mm^2 C1
1 + Bdns

π^2EI
Pc = = 5296.0663691 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3775 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.793095 Cm = 0.2005416385 not ok!
Pc = 5296.1 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.5072158021 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.51365 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 67.942 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 21410.208 KN-mm = 21.410208 KN-m

Moment to be use: 67.942 KN-m

Column Design:
CC= 40

Pu = 839.616 kN
Mu = 67.942 kN.m
e = Mu/Pu = 80.92033 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1291.717

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.376594
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.087069
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 612.5 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 612.5
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 612.5
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C3
1ST FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 1331.938 kN
Pu1 = 1303.432 kN PD PU MY MZ
Lu = 3775 mm -1284.44 -1262.72 6.289 -0.03 ### ### 1.56 -0.2
f'c = 28 Mpa 1331.938 1303.432 6.314 0.03 313 596 1.55 -0.3
Ec = 24870.062324 Mpa
βdns = 1.0218699556

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 3000 1.60E+09 5.33E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m)
B1 379687.5 MY 6.289
1331.938 1303.432
B2 379687.5 MZ 0.03
B3 400000 USE 1331.938 1303.432 6.319
B4 533333.33333

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)
C2
0.7 ΣIgcol. (1/Lcol.) B4
ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

B3B3 B2 B1
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79309 k1 = 0.793095 B1
k2 = 0.893095

B2 C1
0.4 Ec Ig
E1 = = 6.15283E+12
N-mm^2 C1
1 + Bdns

π^2EI
Pc = = 6774.7009224 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3775 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.793095 Cm = 0.2015762926 not ok!
Pc = 6774.7 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.5380171724 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.51365 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 33.23752 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 33237.516 KN-mm = 33.237516 KN-m

Moment to be use: 33.237516 KN-m

Column Design:

Pu = 1303.432 kN
Mu = 6.344 kN.m
e = Mu/Pu = 4.867151 mm 350
270
γ = = 0.771429
350
Pn = Pu/Ф = 2005.28

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.58463
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.00813
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 612.5 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 612.5
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 612.5
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
C3 TOP 3 C3
1ST FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 1331.938 kN
Pu1 = 1303.432 kN PD PU MY MZ
Lu = 3775 mm -1284.44 -826.476 6.293 -0.022 ### ### 1.56 -0.2
f'c = 28 Mpa 1331.938 1303.432 6.314 0.03 313 596 1.55 -0.3
Ec = 24870.062324 Mpa
βdns = 1.0218699556

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 3000 1.60E+09 5.33E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
MU2 C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
(kN.m) C2 416840.27778 (kN.m) (kN.m)
6.314 B1 379687.5 MY 6.293 6.314
1331.938 1303.432
0.03 B2 379687.5 MZ 0.022 0.03
6.344 B3 400000 USE 1331.938 1303.432 6.315 6.344
B4 533333.33333

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)
C2
B4 0.7 ΣIgcol. (1/Lcol.) B4
ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

B1 B3B3 B2 B1
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79309 k1 = 0.793095 B1
k2 = 0.893095

B2 C1
0.4 Ec Ig
E1 = = 6.15283E+12
N-mm^2 C1
1 + Bdns

π^2EI
Pc = = 6774.7009224 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3775 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.793095 Cm = 0.9981715006 ok!
Pc = 6774.7 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.342583521 > 1


≤ 34-12(m1/m2) δ
r USE, 1.342584

r = 105

28.51365 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 44.62414 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 33237.516 KN-mm = 33.237516 KN-m

Moment to be use: 33.237516 KN-m

Column Design:
CC= 40 CC= 40

Pu = 1303.432 kN
Mu = 44.624141259 kN.m
mm e = Mu/Pu = 34.23588 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 2005.28

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.58463
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.057187
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 612.5 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 612.5
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 612.5
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C3
1ST FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 1331.938 kN
Pu1 = 1301.713 kN PD PU MY MZ
Lu = 3775 mm -1284.44 -824.758 -0.003 4.527 ### ### 1.56 -0.2
f'c = 28 Mpa 1331.938 1301.713 0.007 4.584 313 596 1.55 -0.3
Ec = 24870.062324 Mpa
βdns = 1.023219404

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 3000 1.60E+09 5.33E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 312630.20833 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 379687.5 MY 0.003 0.007
1331.938 1301.713
B2 379687.5 MZ 4.527 4.584
B3 400000 USE 1331.938 1301.713 4.53 4.591
B4 533333.33333

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)
C2
0.7 ΣIgcol. (1/Lcol.) B4
ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

B3B3 B2 B1
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79309 k1 = 0.793095 B1
k2 = 0.893095

B2 C1
0.4 Ec Ig
E1 = = 6.14872E+12
N-mm^2 C1
1 + Bdns

π^2EI
Pc = = 6770.1823275 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3775 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.793095 Cm = 0.9946852538 ok!
Pc = 6770.2 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 1.3375933242 > 1


≤ 34-12(m1/m2) δ
r USE, 1.337593

r = 105

28.51365 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 44.39965 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 33193.6815 KN-mm = 33.1936815 KN-m

Moment to be use: 33.1936815 KN-m

Column Design:
CC= 40

Pu = 1301.713 kN
Mu = 44.39964678 kN.m
e = Mu/Pu = 34.10863 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 2002.635

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.583859
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.056899
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 612.5 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 612.5
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 612.5
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1
2ND FLOOR (2 GIRDER CONNECTIONS)
Given
Pd1 = 786.149 kN
Pu1 = 839.712 kN PD PU MY MZ
Lu = 3800 mm -750.524 -809.176 0.012 -0.022 -1101 -1222 3.26
f'c = 28 Mpa 786.149 839.712 -0.012 0.022 798.43 1232 3.1
Ec = 24870.062324 Mpa
βdns = 0.9362126539

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.012
786.149 839.712
B1 266666.66667 B3 266666.66667 MZ 0.022
B2 266666.66667 B4 266666.66667 USE 786.149 839.712 0.034

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.735514
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 3.126302
B B4

ψm = smaller of ψA and ψB = 2.7355 cu.mm B3 C2

k = 0.98678 k1 = 0.993091
k2 = 0.986776

0.4 Ec Ig
A B1
E1 = = 6.42502E+12
N-mm^2
1 + Bdns B2
C1
π^2EI
Pc = = 4509.9360928 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.986776 Cm = 0.2 not ok!
Pc = 4509.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.532095609777 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

35.71188 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 21.412656 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 21412.656 KN-mm = 21.412656 KN-m

Moment to be use: 21.412656 KN-m

Column Design:

Pu = 839.712 kN
Mu = 0.034 kN.m
e = Mu/Pu = 0.04049 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1291.865

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.376637
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 4.36E-05
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
C1 TOP 1 C1
2ND FLOOR (2 GIRDER CONNECTIONS)
Given
Pd1 = 786.149 kN
Pu1 = 708.786 kN PD PU MY MZ
0.42 Lu = 3800 mm -750.524 -700.879 37.349 -0.152 -1101 -1181 2.82 0.42
0.46 f'c = 28 Mpa 786.149 708.786 -37.408 0.157 798.43 1191 2.67 0.46
Ec = 24870.062324 Mpa
βdns = 1.1091486006

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


MU1 MU2 For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
(kN.m) (kN.m) C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
0.012 0.012 C2 416840.27778 C3 416840.27778 MY 37.349 37.408
786.149 708.786
0.022 0.022 B1 266666.66667 B3 266666.66667 MZ 0.152 0.157
0.034 0.034 B2 266666.66667 B4 266666.66667 USE 786.149 708.786 37.501 37.565

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.735514
0.35 ΣIgbeam (1/Lbeam)

B4 ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 3.126302
B B4

ψm = smaller of ψA and ψB = 2.7355 cu.mm B3 C2

k = 0.98678 k1 = 0.993091
k2 = 0.986776
B1
0.4 Ec Ig
A B1
E1 = = 5.89822E+12
N-mm^2
1 + Bdns B2
C1
π^2EI
Pc = = 4140.1517791 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.986776 Cm = 0.2006814854 not ok!
Pc = 4140.2 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.518312025566 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

35.71188 ≤ 46
ing for Mc: Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 37.565 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 18074.043 KN-mm = 18.074043 KN-m

Moment to be use: 37.565 KN-m

Column Design:
CC= 40 CC= 40

Pu = 708.786 kN
Mu = 37.565 kN.m
350 mm e = Mu/Pu = 52.99907 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1090.44

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
0.376637 Kn = = 0.317913
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
4.36E-05 = 0.04814
fc' Ag h

ρg = 0.01 As = ρgAg
sq. mm As = 1225 sq. mm

re Use FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
8 20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
MARY SUMMARY
f't zone Conf't zone
mm ln ### mm 1 - 64 mm
mm Intermediate zone 5 - 128 mm
diate zone Intermediate zone
mm Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C1
2ND FLOOR (2 GIRDER CONNECTIONS)
Given
Pd1 = 786.149 kN
Pu1 = 728.678 kN PD PU MY MZ
Lu = 3800 mm -750.524 -680.987 -0.125 -37.09 -1101 -961 2.76 0.29
f'c = 28 Mpa 786.149 728.678 0.12 37.122 798.43 971 2.65 0.3
Ec = 24870.062324 Mpa
βdns = 1.078870228

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.125 0.12
786.149 728.678
B1 266666.66667 B3 266666.66667 MZ 37.09 37.122
B2 266666.66667 B4 266666.66667 USE 786.149 728.678 37.215 37.242

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.735514
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 3.126302
B B4

ψm = smaller of ψA and ψB = 2.7355 cu.mm B3 C2

k = 0.98678 k1 = 0.993091
k2 = 0.986776

0.4 Ec Ig
A B1
E1 = = 5.98412E+12
N-mm^2
1 + Bdns B2
C1
π^2EI
Pc = = 4200.4523483 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.986776 Cm = 0.2002899952 not ok!
Pc = 4200.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.520360020894 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

35.71188 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 37.242 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 18581.289 KN-mm = 18.581289 KN-m

Moment to be use: 37.242 KN-m

Column Design:
CC= 40

Pu = 728.678 kN
Mu = 37.242 kN.m
e = Mu/Pu = 51.10899 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1121.043

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.326835
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.047726
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C1
2ND FLOOR (2 GIRDER CONNECTIONS)
Given
Pd1 = 786.149 kN
Pu1 = 823.458 kN PD PU MY MZ
Lu = 3275 mm -750.524 -792.922 0.009 -0.019 -1101 -1222 3.26 0.42
f'c = 28 Mpa 786.149 823.458 0.009 0.019 798.43 1232 3.1 0.46
Ec = 24870.062324 Mpa
βdns = 0.9546922855

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3500 1.25E+09 3.57E+05
Column 2 (C2) 350 350 3200 1.25E+09 3.91E+05
Column 3 (C3) 350 350 3200 1.25E+09 3.91E+05
Beam 1 (B1) 450 300 5200 2.28E+09 4.38E+05
Beam 2 (B2) 450 300 5500 2.28E+09 4.14E+05
Beam 3 (B3) 450 300 5500 2.28E+09 4.14E+05
Beam 4 (B4) 450 300 5200 2.28E+09 4.38E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 357291.66667 C2 390787.76042 (kN.m) (kN.m)
C2 390787.76042 C3 390787.76042 MY 0.009 0.009
786.149 823.458
B1 438100.96154 B3 414204.54545 MZ 0.019 0.019
B2 414204.54545 B4 438100.96154 USE 786.149 823.458 0.028 0.028

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.7554255
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.8340267
B B4

ψm = smaller of ψA and ψB = 1.7554 cu.mm B3 C2

k = 0.87947 k1 = 0.879473
k2 = 0.937771

0.4 Ec Ig
A B1
E1 = = 6.36428E+12
N-mm^2
1 + Bdns B2
C1
π^2EI
Pc = = 7571.4994655 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3275 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.879473 Cm = 0.2 not ok!
Pc = 7571.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.467841791476 < 1


≤ 34-12(m1/m2) δ
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

27.43117 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 20.998179 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 20998.179 KN-mm = 20.998179 KN-m

Moment to be use: 20.998179 KN-m

Column Design:
CC= 40

Pu = 823.458 kN
Mu = 0.028 kN.m
e = Mu/Pu = 0.034003 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1266.858

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.369346
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 3.59E-05
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 529.16666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 529.1667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 529.1667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm
Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C1
2ND FLOOR (2 GIRDER CONNECTIONS)
Given
Pd1 = 786.149 kN
Pu1 = 494.068 kN PD PU MY MZ
Lu = 3275 mm -750.524 -493.794 37.346 -0.146 -1101 -1181 2.82 0.42
f'c = 28 Mpa 786.149 494.068 -37.404 0.151 798.43 1191 2.67 0.46
Ec = 24870.062324 Mpa
βdns = 1.5911757086

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3500 1.25E+09 3.57E+05
Column 2 (C2) 350 350 3200 1.25E+09 3.91E+05
Column 3 (C3) 350 350 3200 1.25E+09 3.91E+05
Beam 1 (B1) 450 300 5200 2.28E+09 4.38E+05
Beam 2 (B2) 450 300 5500 2.28E+09 4.14E+05
Beam 3 (B3) 450 300 5500 2.28E+09 4.14E+05
Beam 4 (B4) 450 300 5200 2.28E+09 4.38E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 357291.66667 C2 390787.76042 (kN.m) (kN.m)
C2 390787.76042 C3 390787.76042 MY 37.346 37.404
786.149 494.068
B1 438100.96154 B3 414204.54545 MZ 0.146 0.151
B2 414204.54545 B4 438100.96154 USE 786.149 494.068 37.492 37.555

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.7554255
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.8340267
B B4

ψm = smaller of ψA and ψB = 1.7554 cu.mm B3 C2

k = 0.87947 k1 = 0.879473
k2 = 0.937771

0.4 Ec Ig
A B1
E1 = = 4.80099E+12
N-mm^2
1 + Bdns B2
C1
π^2EI
Pc = = 5711.6742587 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3275 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.879473 Cm = 0.2006710158 not ok!
Pc = 5711.7 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.452148677136 < 1


≤ 34-12(m1/m2) δ
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

27.43117 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 37.555 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 12598.734 KN-mm = 12.598734 KN-m

Moment to be use: 37.555 KN-m

Column Design:
CC= 40

Pu = 494.068 kN
Mu = 37.555 kN.m
e = Mu/Pu = 76.0118 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 760.1046

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.221605
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.048127
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 529.16666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 529.1667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 529.1667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm
Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C1
2ND FLOOR (2 GIRDER CONNECTIONS)
Given
Pd1 = 786.149 kN
Pu1 = 513.959 kN PD PU MY MZ
Lu = 3275 mm -750.524 -473.902 -0.128 -37.084 -1101 -961 2.76 0.29
f'c = 28 Mpa 786.149 513.959 0.124 37.116 798.43 971 2.65 0.3
Ec = 24870.062324 Mpa
βdns = 1.5295947731

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3500 1.25E+09 3.57E+05
Column 2 (C2) 350 350 3200 1.25E+09 3.91E+05
Column 3 (C3) 350 350 3200 1.25E+09 3.91E+05
Beam 1 (B1) 450 300 5200 2.28E+09 4.38E+05
Beam 2 (B2) 450 300 5500 2.28E+09 4.14E+05
Beam 3 (B3) 450 300 5500 2.28E+09 4.14E+05
Beam 4 (B4) 450 300 5200 2.28E+09 4.38E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 357291.66667 C2 390787.76042 (kN.m) (kN.m)
C2 390787.76042 C3 390787.76042 MY 0.128 0.124
786.149 513.959
B1 438100.96154 B3 414204.54545 MZ 37.084 37.116
B2 414204.54545 B4 438100.96154 USE 786.149 513.959 37.212 37.24

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.7554255
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.8340267
B B4

ψm = smaller of ψA and ψB = 1.7554 cu.mm B3 C2

k = 0.87947 k1 = 0.879473
k2 = 0.937771

0.4 Ec Ig
A B1
E1 = = 4.91787E+12
N-mm^2
1 + Bdns B2
C1
π^2EI
Pc = = 5850.7203414 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3275 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.879473 Cm = 0.2003007519 not ok!
Pc = 5850.7 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.453066414051 < 1


≤ 34-12(m1/m2) δ
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

27.43117 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 37.24 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 13105.9545 KN-mm = 13.1059545 KN-m

Moment to be use: 37.24 KN-m

Column Design:
CC= 40

Pu = 513.959 kN
Mu = 37.24 kN.m
e = Mu/Pu = 72.45714 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 790.7062

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.230527
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.047724
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 529.16666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 529.1667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 529.1667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm
Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C1
2ND FLOOR (2 GIRDER CONNECTIONS)
Given
Pd1 = 786.149 kN
Pu1 = 784.976 kN PD PU MY MZ
Lu = 3800 mm -750.524 -754.44 2.793 -0.019 -1101 -1222 3.26 0.42
f'c = 28 Mpa 786.149 784.976 2.78 0.019 798.43 1232 3.1 0.46
Ec = 24870.062324 Mpa
βdns = 1.0014943132

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 2.793 2.78
786.149 784.976
B1 266666.66667 B3 266666.66667 MZ 0.019 0.019
B2 266666.66667 B4 266666.66667 USE 786.149 784.976 2.799 2.812

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.7355143
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 3.1263021
B B4

ψm = smaller of ψA and ψB = 2.7355 cu.mm B3 C2

k = 0.98678 k1 = 0.993091
k2 = 0.986776

0.4 Ec Ig
A B1
E1 = = 6.21546E+12
N-mm^2
1 + Bdns B2
C1
π^2EI
Pc = = 4362.8379423 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.986776 Cm = 0.2018492176 not ok!
Pc = 4362.8 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.526244934904 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

35.71188 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 20.016888 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 20016.888 KN-mm = 20.016888 KN-m

Moment to be use: 20.016888 KN-m

Column Design:
CC= 40
Pu = 784.976 kN
Mu = 2.812 kN.m
e = Mu/Pu = 3.582275 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1207.655

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.352086
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.003604
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C1
2ND FLOOR (2 GIRDER CONNECTIONS)
Given
Pd1 = 786.149 kN
Pu1 = 506.155 kN PD PU MY MZ
Lu = 3800 mm -750.524 -754.44 2.793 -0.019 -1101 -1181 2.82 0.42
f'c = 28 Mpa 786.149 506.155 2.786 0.011 798.43 1191 2.67 0.46
Ec = 24870.062324 Mpa
βdns = 1.5531783742

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 2.793 2.786
786.149 506.155
B1 266666.66667 B3 266666.66667 MZ 0.019 0.011
B2 266666.66667 B4 266666.66667 USE 786.149 506.155 2.797 2.812

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.7355143
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 3.1263021
B B4

ψm = smaller of ψA and ψB = 2.7355 cu.mm B3 C2

k = 0.98678 k1 = 0.993091
k2 = 0.986776

0.4 Ec Ig
A B1
E1 = = 4.87244E+12
N-mm^2
1 + Bdns B2
C1
π^2EI
Pc = = 3420.1274064 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.986776 Cm = 0.2021337127 not ok!
Pc = 3420.1 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.498333096373 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

35.71188 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 12.9069525 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 12906.9525 KN-mm = 12.9069525 KN-m

Moment to be use: 12.9069525 KN-m

Column Design:
CC= 40
Pu = 506.155 kN
Mu = 2.812 kN.m
e = Mu/Pu = 5.55561 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 778.7

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.227026
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.003604
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C1
2ND FLOOR (2 GIRDER CONNECTIONS)
Given
Pd1 = 786.149 kN
Pu1 = 784.626 kN PD PU MY MZ
Lu = 3800 mm -750.524 -482.903 0.003 2.001 -1101 -961 2.76 0.29
f'c = 28 Mpa 786.149 784.626 -0.009 2.032 798.43 971 2.65 0.3
Ec = 24870.062324 Mpa
βdns = 1.0019410522

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.003 0.009
786.149 784.626
B1 266666.66667 B3 266666.66667 MZ 2.001 2.032
B2 266666.66667 B4 266666.66667 USE 786.149 784.626 2.004 2.041

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.7355143
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 3.1263021
B B4

ψm = smaller of ψA and ψB = 2.7355 cu.mm B3 C2

k = 0.98678 k1 = 0.993091
k2 = 0.986776

0.4 Ec Ig
A B1
E1 = = 6.21408E+12
N-mm^2
1 + Bdns B2
C1
π^2EI
Pc = = 4361.8643624 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.986776 Cm = 0.2072513474 not ok!
Pc = 4361.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.52620793772 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

35.71188 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 20.007963 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 20007.963 KN-mm = 20.007963 KN-m

Moment to be use: 20.007963 KN-m

Column Design:
CC= 40
Pu = 784.626 kN
Mu = 2.041 kN.m
e = Mu/Pu = 2.601239 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1207.117

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.351929
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.002616
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C2
2ND FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 788.196 kN
Pu1 = 845.914 kN PD PU MY MZ -431 -589.8 1.56 -0.2
Lu = 3800 mm -752.571 -815.378 0.012 -0.022 -774 -1187 2.89 0.42
f'c = 28 Mpa 788.196 845.914 -0.012 0.022 562 1197 2.73 0.46
Ec = 24870.062324 Mpa
βdns = 0.9317684776

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.012 0.012
788.196 845.914
B1 266666.66667 B4 266666.66667 MZ 0.022 0.022
B2 379687.5 B5 379687.5 USE 788.196 845.914 0.034 0.034
B3 400000 B6 400000

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959 B6 B B4

ψm = smaller of ψA and ψB = 1.3943 cu.mm


B5 C2

k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig
E1 = = 6.43981E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 6100.8554705 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.2 not ok!
Pc = 6100.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.49072126333 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 21.570807 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 21570.807 KN-mm = 21.570807 KN-m

Moment to be use: 21.570807 KN-m

Column Design:
CC= 40

Pu = 845.914 kN
Mu = 0.034 kN.m
e = Mu/Pu = 0.040193 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1301.406

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.379419
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 4.36E-05
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES
A.) 16db = 256 mm
B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C2 TOP 3
2ND FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 788.196 kN
Pu1 = 827.992 kN PD PU MY MZ -431 -590 1.56 -0.2
Lu = 3800 mm -752.571 -797.456 0.009 -0.019 -774 -947 2.52 0.29
f'c = 28 Mpa 788.196 827.992 0.009 0.019 562 958 2.41 0.3
Ec = 24870.062324 Mpa
βdns = 0.9519367337

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.009 0.009
788.196 827.992
B1 266666.66667 B4 266666.66667 MZ 0.019 0.019
B2 379687.5 B5 379687.5 USE 788.196 827.992 0.028 0.028
B3 400000 B6 400000

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959 B6 B B4

ψm = smaller of ψA and ψB = 1.3943 cu.mm


B5 C2

k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig
E1 = = 6.37327E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 6037.8187885 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.2 not ok!
Pc = 6037.8 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.48950364769 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 21.113796 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 21113.796 KN-mm = 21.113796 KN-m

Moment to be use: 21.113796 KN-m

Column Design:
CC= 40

Pu = 827.992 kN
Mu = 0.028 kN.m
e = Mu/Pu = 0.033817 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1273.834

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.37138
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 3.59E-05
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES
A.) 16db = 256 mm
B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C2
2ND FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 788.196 kN
Pu1 = 789.219 kN PD PU MY MZ -431 -590 1.56 -0.2
Lu = 3800 mm -752.571 -758.684 0.009 1.993 -774 -947 2.52 0.29
f'c = 28 Mpa 788.196 789.219 -0.009 2.032 562 958 2.41 0.3
Ec = 24870.062324 Mpa
βdns = 0.9987037818

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.009 0.009
788.196 789.219
B1 266666.66667 B4 266666.66667 MZ 1.993 2.032
B2 379687.5 B5 379687.5 USE 788.196 789.219 2.002 2.041
B3 400000 B6 400000

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959 B6 B B4

ψm = smaller of ψA and ψB = 1.3943 cu.mm


B5 C2

k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig
E1 = = 6.22414E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 5896.5417446 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.2076433121 not ok!
Pc = 5896.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.48688998755 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 20.125085 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 20125.0845 KN-mm = 20.1250845 KN-m

Moment to be use: 20.1250845 KN-m

Column Design:
CC= 40

Pu = 789.219 kN
Mu = 2.041 kN.m
e = Mu/Pu = 2.586101 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1214.183

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.353989
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.002616
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES
A.) 16db = 256 mm
B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C2
2ND FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 788.196 kN
Pu1 = 727.526 kN PD PU MY MZ
Lu = 3800 mm -752.571 -688.427 37.349 0.017 ### ### 60 -33
f'c = 28 Mpa 788.196 727.526 -37.408 -0.013 ### ### 59 -33
Ec = 24870.062324 Mpa
βdns = 1.0833922087

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 400 400 4000 2.13E+09 5.33E+05
Column 2 (C2) 400 400 3000 2.13E+09 7.11E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 533333.33333 fixed 1.0 MU Non-Sway (Beam No. )
C2 711111.11111 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 37.349 37.408
788.196 727.526
B3 266666.66667 MZ 0.017 0.013
USE 788.196 727.526 37.366 37.421

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.37863
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 2.3786 cu.mm
B3 B2
k = 0.86893 k1 = 0.868931
k2 = 0.968931 B1
0.4 Ec Ig C1
E1 = = 1.01865E+13
N-mm^2
1 + Bdns

π^2EI
Pc = = 9221.1703048 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 2.13E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.868931 Cm = 0.9994120948 ok!
Pc = 9221.2 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.116906755 > 1
≤ 34-12(m1/m2) δ
r USE, 1.116907

r = 105

31.44704 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 41.79577 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 18551.913 KN-mm = 18.551913 KN-m

Moment to be use: 37.421 KN-m

Column Design:
CC= 58

Pu = 727.526 kN
Mu = 41.79576768 kN.m
e = Mu/Pu = 57.44917 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 1119.271

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.326318
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.053562
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C2
2ND FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 788.196 kN
Pu1 = 510.979 kN PD PU MY MZ
Lu = 3800 mm -752.571 -479.514 37.346 0.023 ### ### 59 -33
f'c = 28 Mpa 788.196 510.979 -37.404 -0.019 ### ### 59 -33
Ec = 24870.062324 Mpa
βdns = 1.5425213169

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 400 400 4000 2.13E+09 5.33E+05
Column 2 (C2) 400 400 3000 2.13E+09 7.11E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 533333.33333 fixed 1.0 MU Non-Sway (Beam No. )
C2 711111.11111 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 37.346 37.404
788.196 510.979
B3 266666.66667 MZ 0.023 0.019
USE 788.196 510.979 37.369 37.423

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.37863
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 2.3786 cu.mm
B3 B2
k = 0.86893 k1 = 0.868931
k2 = 0.968931 B1
0.4 Ec Ig C1
E1 = = 8.34701E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 7556.009163 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 2.13E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.868931 Cm = 0.9994228148 ok!
Pc = 7556.0 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.0984688408 > 1
≤ 34-12(m1/m2) δ
r USE, 1.098469

r = 105

31.44704 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 41.108 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 13029.9645 KN-mm = 13.0299645 KN-m

Moment to be use: 37.423 KN-m

Column Design:
CC= 58

Pu = 510.979 kN
Mu = 41.10799943 kN.m
e = Mu/Pu = 80.44949 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 786.1215

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.22919
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.052681
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C2
2ND FLOOR (3 GIRDER CONNECTIONS)
Given
Pd1 = 788.196 kN
Pu1 = 506.405 kN PD PU MY MZ
Lu = 3800 mm -752.571 -757.908 2.793 -0.019 ### ### 59 -33
f'c = 28 Mpa 788.196 506.405 2.786 0.011 ### ### 59 -33
Ec = 24870.062324 Mpa
βdns = 1.5564538265

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 400 400 4000 2.13E+09 5.33E+05
Column 2 (C2) 400 400 3000 2.13E+09 7.11E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 533333.33333 fixed 1.0 MU Non-Sway (Beam No. )
C2 711111.11111 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 2.793 2.786
788.196 506.405
B3 266666.66667 MZ 0.019 0.011
USE 788.196 506.405 2.797 2.812

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.37863
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 2.3786 cu.mm
B3 B2
k = 0.86893 k1 = 0.868931
k2 = 0.968931 B1
0.4 Ec Ig C1
E1 = = 8.30152E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 7514.8293972 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 2.13E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.868931 Cm = 0.9978662873 ok!
Pc = 7514.8 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.0963755175 > 1
≤ 34-12(m1/m2) δ
r USE, 1.096376

r = 105

31.44704 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 14.15786 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 12913.3275 KN-mm = 12.9133275 KN-m

Moment to be use: 12.9133275 KN-m

Column Design:
CC= 40

Pu = 506.405 kN
Mu = 14.15785612 kN.m
e = Mu/Pu = 27.95758 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 779.0846

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.227138
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.018144
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C2
SECOND FLOOR(3 GIRDER CONNECTIONS)
Given
Pd1 = 788.196 kN
Pu1 = 733.029 kN PD PU MY MZ
Lu = 3800 mm -752.571 -682.925 -0.125 -37.204 ### ### 60 -33
f'c = 28 Mpa 788.196 733.029 0.12 37.236 ### ### 59 -33
Ec = 24870.062324 Mpa
βdns = 1.0752589597

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 400 400 4000 2.13E+09 5.33E+05
Column 2 (C2) 400 400 3000 2.13E+09 7.11E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 533333.33333 fixed 1.0 MU Non-Sway (Beam No. )
C2 711111.11111 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 0.125 0.12
788.196 733.029
B3 266666.66667 MZ 37.204 37.236
USE 788.196 733.029 37.329 37.356

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.37863
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 2.3786 cu.mm
B3 B2
k = 0.86893 k1 = 0.868931
k2 = 0.968931 B1
0.4 Ec Ig C1
E1 = = 1.02264E+13
N-mm^2
1 + Bdns

π^2EI
Pc = = 9257.3094445 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 400 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 2.13E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.868931 Cm = 0.9997108898 ok!
Pc = 9257.3 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.1177177514 > 1
≤ 34-12(m1/m2) δ
r USE, 1.117718

r = 120

27.51616 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 41.75346 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 19791.783 KN-mm = 19.791783 KN-m

Moment to be use: 37.356 KN-m

Column Design:
CC= 58

Pu = 733.029 kN
Mu = 41.753464321 kN.m
e = Mu/Pu = 56.96018 mm 400 mm
284
γ = = 0.71
400
Pn = Pu/Ф = 1127.737

400 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.71 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.251727
f'cAg
0.6 - 0.7 0.6 - 0.71
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.035846
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1600 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 7.96178343949045
20 mm 5.09554140127389 16 8
25 mm 3.26114649681529
28 mm 2.5997660210581
32 mm 1.99044585987261
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 126 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 200
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 400 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 400 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C2
SECOND FLOOR(3 GIRDER CONNECTIONS)
Given
Pd1 = 788.196 kN
Pu1 = 516.481 kN PD PU MY MZ
Lu = 3800 mm -752.571 -474.012 -0.128 -37.199 ### ### 59 -33
f'c = 28 Mpa 788.196 516.481 0.124 37.23 ### ### 59 -33
Ec = 24870.062324 Mpa
βdns = 1.5260890526

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 400 400 4000 2.13E+09 5.33E+05
Column 2 (C2) 400 400 3000 2.13E+09 7.11E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 533333.33333 fixed 1.0 MU Non-Sway (Beam No. )
C2 711111.11111 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 0.128 0.124
788.196 516.481
B3 266666.66667 MZ 37.199 37.23
USE 788.196 516.481 37.327 37.354

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.37863
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 2.3786 cu.mm
B3 B2
k = 0.86893 k1 = 0.868931
k2 = 0.968931 B1
0.4 Ec Ig C1
E1 = = 8.40131E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 7605.1611671 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 400 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 2.13E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.868931 Cm = 0.9997108743 ok!
Pc = 7605.2 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.0992468037 > 1
≤ 34-12(m1/m2) δ
r USE, 1.099247

r = 120

27.51616 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 41.06127 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 13944.987 KN-mm = 13.944987 KN-m

Moment to be use: 37.354 KN-m

Column Design:
CC= 58

Pu = 516.481 kN
Mu = 41.061265105 kN.m
e = Mu/Pu = 79.50199 mm 400 mm
284
γ = = 0.71
400
Pn = Pu/Ф = 794.5862

400 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.71 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.177363
f'cAg
0.6 - 0.7 0.6 - 0.71
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.035252
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1600 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 7.96178343949045
20 mm 5.09554140127389 16 8
25 mm 3.26114649681529
28 mm 2.5997660210581
32 mm 1.99044585987261
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 126 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 200
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 400 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 400 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C2
SECOND FLOOR(3 GIRDER CONNECTIONS)
Given
Pd1 = 788.196 kN
Pu1 = 789.219 kN PD PU MY MZ
Lu = 3800 mm -752.571 -484.278 0.003 2.001 ### ### 59 -33
f'c = 28 Mpa 788.196 789.219 -0.009 2.032 ### ### 59 -33
Ec = 24870.062324 Mpa
βdns = 0.9987037818

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 400 400 4000 2.13E+09 5.33E+05
Column 2 (C2) 400 400 3000 2.13E+09 7.11E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 4000 1.60E+09 4.00E+05
Beam 3 (B3) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections


For A Ig/L For B Ig/L Given:
C1 533333.33333 fixed 1.0 MU Non-Sway (Beam No. )
C2 711111.11111 MU1 MU2
Pd (kN) Pu (kN)
B1 379687.5 (kN.m) (kN.m)
B2 400000 MY 0.003 0.009
788.196 789.219
B3 266666.66667 MZ 2.001 2.032
USE 788.196 789.219 2.004 2.041

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 2.37863
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam)
C2
ψm = smaller of ψA and ψB = 2.3786 cu.mm
B3 B2
k = 0.86893 k1 = 0.868931
k2 = 0.968931 B1
0.4 Ec Ig C1
E1 = = 1.06181E+13
N-mm^2
1 + Bdns

π^2EI
Pc = = 9611.8867349 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa P
Lu = 3800 mm
Dimension = 400 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 2.13E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.868931 Cm = 0.9927486526 ok!
Pc = 9611.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.1147943215 > 1
≤ 34-12(m1/m2) δ
r USE, 1.114794

r = 120

27.51616 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 23.75506 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 21308.913 KN-mm = 21.308913 KN-m

Moment to be use: 21.308913 KN-m

Column Design:
CC= 58

Pu = 789.219 kN
Mu = 23.755055211 kN.m
e = Mu/Pu = 30.09945 mm 400 mm
284
γ = = 0.71
400
Pn = Pu/Ф = 1214.183

400 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.71 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.271023
f'cAg
0.6 - 0.7 0.6 - 0.71
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.020394
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1600 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 7.96178343949045
20 mm 5.09554140127389 16 8
25 mm 3.26114649681529
28 mm 2.5997660210581
32 mm 1.99044585987261
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 126 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 200
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 400 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 400 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C3
2ND FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 785.297 kN
Pu1 = 843.135 kN PD PU MY MZ -431 -589.8
Lu = 3800 mm -749.672 -812.599 0.012 -0.022 -747 -1141 2.89 0.31
f'c = 28 Mpa 785.297 843.135 -0.012 0.022 541.9 1151.2 2.73 0.35
Ec = 24870.062324 Mpa
βdns = 0.9314012584
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.012 0.012
785.297 843.135
B1 379687.5 B4 379687.5 MZ 0.022 0.022
B2 533333.33333 B5 379687.5 USE 785.297 843.135 0.034 0.034
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 6.44103E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 7012.2587029 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 1 ok!
Pc = 7012.3 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.19092475775 > 1
≤ 34-12(m1/m2) δ
r USE, 1.19092476

r = 105

28.67538 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 25.604814 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 21499.9425 KN-mm = 21.4999425 KN-m

Moment to be use: 21.4999425 KN-m

Column Design:
CC= 40

Pu = 843.135 kN
Mu = 25.604813814 kN.m
e = Mu/Pu = 30.36858 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1297.131

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.378172
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.032813
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C3
2ND FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 785.297 kN
Pu1 = 825.323 kN PD PU MY MZ -431 -590
Lu = 3800 mm -749.672 -794.787 0.009 -0.019 313 -915 2.52 0.21
f'c = 28 Mpa 785.297 825.323 0.009 0.019 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 0.9515026238
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.009 0.009
785.297 825.323
B1 379687.5 B4 379687.5 MZ 0.019 0.019
B2 533333.33333 B5 379687.5 USE 785.297 825.323 0.028 0.028
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 6.37468E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 6940.0292461 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 1 ok!
Pc = 6940.0 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.18844286156 > 1
≤ 34-12(m1/m2) δ
r USE, 1.1884429

r = 105

28.67538 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 25.011655 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 21045.7365 KN-mm = 21.0457365 KN-m

Moment to be use: 21.0457365 KN-m

Column Design:
CC= 40

Pu = 825.323 kN
Mu = 25.01165531 kN.m
e = Mu/Pu = 30.30529 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1269.728

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.370183
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.032053
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C3
2ND FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 785.297 kN
Pu1 = 786.408 kN PD PU MY MZ -431 -590
Lu = 3800 mm -749.672 -755.872 0.009 1.993 313 -915 2.52 0.21
f'c = 28 Mpa 785.297 786.408 -0.009 2.032 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 0.9985872473
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.009 0.009
785.297 786.408
B1 379687.5 B4 379687.5 MZ 1.993 2.032
B2 533333.33333 B5 379687.5 USE 785.297 786.408 2.002 2.041
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 6.2245E+12N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 6776.5294216 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.9923566879 ok!
Pc = 6776.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 1.17401386304 > 1
≤ 34-12(m1/m2) δ
r USE, 1.1740139

r = 105

28.67538 > 22
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 23.542974 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 20053.404 KN-mm = 20.053404 KN-m

Moment to be use: 20.053404 KN-m

Column Design:
CC= 40

Pu = 786.408 kN
Mu = 23.542974297 kN.m
e = Mu/Pu = 29.93735 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1209.858

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.352728
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.030171
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C3
2ND FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 785.297 kN
Pu1 = 728.396 kN PD PU MY MZ -431 -589.8
Lu = 3275 mm -749.672 -682.404 37.286 0.06 -747 -1141 2.89 0.31
f'c = 28 Mpa 785.297 728.396 -37.344 -0.055 541.9 1151.2 2.73 0.35
Ec = 24870.062324 Mpa
βdns = 1.0781182214
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3500 1.25E+09 3.57E+05
Column 2 (C2) 350 350 3200 1.25E+09 3.91E+05
Column 3 (C3) 350 350 3200 1.25E+09 3.91E+05
Beam 1 (B1) 450 300 4000 2.28E+09 5.70E+05
Beam 2 (B2) 450 300 5500 2.28E+09 4.14E+05
Beam 3 (B3) 450 300 4000 2.28E+09 5.70E+05
Beam 4 (B4) 450 300 5500 2.28E+09 4.14E+05
Beam 5 (B5) 450 300 4000 2.28E+09 5.70E+05
Beam 6 (B6) 450 300 5500 2.28E+09 4.14E+05
Beam 7 (B7) 450 300 4000 2.28E+09 5.70E+05
Beam 8 (B8) 450 300 5500 2.28E+09 4.14E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 357291.66667 C2 390787.76042 (kN.m) (kN.m)
C2 390787.76042 C3 390787.76042 MY 37.286 37.344
785.297 728.396
B1 569531.25 B4 414204.54545 MZ 0.06 0.055
B2 414204.54545 B5 569531.25 USE 785.297 728.396 37.346 37.399
B3 569531.25 B6 414204.54545
B4 569531.25 B7 569531.25
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.704805
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.7944974
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.7048 cu.mm

k = 0.77497 k1 = 0.774965
k2 = 0.88524
B3 A B1

0.4 Ec Ig
E1 = = 5.98629E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 9172.1335839 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3275 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.774965 Cm = 0.2005668601 not ok!
Pc = 9172.1 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.44736992564 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.17153 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 37.399 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 18574.098 KN-mm = 18.574098 KN-m

Moment to be use: 37.399 KN-m

Column Design:
CC= 40

Pu = 728.396 kN
Mu = 37.399 kN.m
e = Mu/Pu = 51.34432 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1120.609

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.326708
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.047927
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 529.16666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 529.1667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 529.1667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C3
2ND FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 785.297 kN
Pu1 = 512.562 kN PD PU MY MZ -431 -590
Lu = 3275 mm -749.672 -474.204 37.282 0.065 313 -915 2.52 0.21
f'c = 28 Mpa 785.297 512.562 -37.341 -0.061 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 1.5321014824
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3500 1.25E+09 3.57E+05
Column 2 (C2) 350 350 3200 1.25E+09 3.91E+05
Column 3 (C3) 350 350 3200 1.25E+09 3.91E+05
Beam 1 (B1) 450 300 4000 2.28E+09 5.70E+05
Beam 2 (B2) 450 300 5500 2.28E+09 4.14E+05
Beam 3 (B3) 450 300 4000 2.28E+09 5.70E+05
Beam 4 (B4) 450 300 5500 2.28E+09 4.14E+05
Beam 5 (B5) 450 300 4000 2.28E+09 5.70E+05
Beam 6 (B6) 450 300 5500 2.28E+09 4.14E+05
Beam 7 (B7) 450 300 4000 2.28E+09 5.70E+05
Beam 8 (B8) 450 300 5500 2.28E+09 4.14E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 357291.66667 C2 390787.76042 (kN.m) (kN.m)
C2 390787.76042 C3 390787.76042 MY 37.282 37.341
785.297 512.562
B1 569531.25 B4 414204.54545 MZ 0.065 0.061
B2 414204.54545 B5 569531.25 USE 785.297 512.562 37.347 37.402
B3 569531.25 B6 414204.54545
B4 569531.25 B7 569531.25
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.704805
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.7944974
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.7048 cu.mm

k = 0.77497 k1 = 0.774965
k2 = 0.88524
B3 A B1

0.4 Ec Ig
E1 = = 4.913E+12N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 7527.6516611 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3275 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.774965 Cm = 0.2005882038 not ok!
Pc = 7527.7 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.43994111447 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.17153 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 37.402 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 13070.331 KN-mm = 13.070331 KN-m

Moment to be use: 37.402 KN-m

Column Design:
CC= 40

Pu = 512.562 kN
Mu = 37.402 kN.m
e = Mu/Pu = 72.97068 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 788.5569

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.2299
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.047931
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 529.16666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 529.1667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 529.1667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C3
2ND FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 785.297 kN
Pu1 = 504.305 kN PD PU MY MZ -431 -590
Lu = 3275 mm -749.672 -755.004 2.793 -0.019 313 -915 2.52 0.21
f'c = 28 Mpa 785.297 504.305 2.786 0.011 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 1.5571866232
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3500 1.25E+09 3.57E+05
Column 2 (C2) 350 350 3200 1.25E+09 3.91E+05
Column 3 (C3) 350 350 3200 1.25E+09 3.91E+05
Beam 1 (B1) 450 300 4000 2.28E+09 5.70E+05
Beam 2 (B2) 450 300 5500 2.28E+09 4.14E+05
Beam 3 (B3) 450 300 4000 2.28E+09 5.70E+05
Beam 4 (B4) 450 300 5500 2.28E+09 4.14E+05
Beam 5 (B5) 450 300 4000 2.28E+09 5.70E+05
Beam 6 (B6) 450 300 5500 2.28E+09 4.14E+05
Beam 7 (B7) 450 300 4000 2.28E+09 5.70E+05
Beam 8 (B8) 450 300 5500 2.28E+09 4.14E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 357291.66667 C2 390787.76042 (kN.m) (kN.m)
C2 390787.76042 C3 390787.76042 MY 2.793 2.786
785.297 504.305
B1 569531.25 B4 414204.54545 MZ 0.019 0.011
B2 414204.54545 B5 569531.25 USE 785.297 504.305 2.797 2.812
B3 569531.25 B6 414204.54545
B4 569531.25 B7 569531.25
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.704805
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.7944974
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.7048 cu.mm

k = 0.77497 k1 = 0.774965
k2 = 0.88524
B3 A B1

0.4 Ec Ig
E1 = = 4.8648E+12N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 7453.8079298 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3275 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.774965 Cm = 0.2021337127 not ok!
Pc = 7453.8 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.43966181269 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.17153 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 12.859778 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 12859.7775 KN-mm = 12.8597775 KN-m

Moment to be use: 12.8597775 KN-m

Column Design:
CC= 40

Pu = 504.305 kN
Mu = 2.812 kN.m
e = Mu/Pu = 5.575991 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 775.8538

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.226196
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.003604
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 529.16666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 529.1667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 529.1667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C3
2ND FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 785.297 kN
Pu1 = 727.567 kN PD PU MY MZ -431 -589.8
Lu = 3800 mm -749.672 -683.232 -0.082 -37.233 -747 -1141 2.89 0.31
f'c = 28 Mpa 785.297 727.567 0.078 37.265 541.9 1151.2 2.73 0.35
Ec = 24870.062324 Mpa
βdns = 1.0793466444
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.082 0.078
785.297 727.567
B1 379687.5 B4 379687.5 MZ 37.233 37.265
B2 533333.33333 B5 379687.5 USE 785.297 727.567 37.315 37.343
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 5.98275E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 6513.3369272 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2002999223 not ok!
Pc = 6513.3 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.47000151568 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 37.343 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 18552.9585 KN-mm = 18.5529585 KN-m

Moment to be use: 37.343 KN-m

Column Design:
CC= 40

Pu = 727.567 kN
Mu = 37.343 kN.m
e = Mu/Pu = 51.32586 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1119.334

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.326336
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.047856
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C3
2ND FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 785.297 kN
Pu1 = 511.733 kN PD PU MY MZ -431 -590
Lu = 3800 mm -749.672 -475.032 -0.085 -37.227 313 -915 2.52 0.21
f'c = 28 Mpa 785.297 511.733 0.081 37.259 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 1.5345834644
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.085 0.081
785.297 511.733
B1 379687.5 B4 379687.5 MZ 37.227 37.259
B2 533333.33333 B5 379687.5 USE 785.297 511.733 37.312 37.34
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 4.90819E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 5343.4757518 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2002999464 not ok!
Pc = 5343.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.45855279993 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 37.34 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 13049.1915 KN-mm = 13.0491915 KN-m

Moment to be use: 37.34 KN-m

Column Design:
CC= 40

Pu = 511.733 kN
Mu = 37.34 kN.m
e = Mu/Pu = 72.96774 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 787.2815

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.229528
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.047852
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C3
2ND FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 785.297 kN
Pu1 = 786.408 kN PD PU MY MZ -431 -590
Lu = 3800 mm -749.672 -482.272 0.003 2.001 313 -915 2.52 0.21
f'c = 28 Mpa 785.297 786.408 -0.009 2.032 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 0.9985872473
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.003 0.009
785.297 786.408
B1 379687.5 B4 379687.5 MZ 2.001 2.032
B2 533333.33333 B5 379687.5 USE 785.297 786.408 2.004 2.041
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 6.2245E+12N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 6776.5294216 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2072513474 not ok!
Pc = 6776.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.47322253273 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 20.053404 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 20053.404 KN-mm = 20.053404 KN-m

Moment to be use: 20.053404 KN-m

Column Design:
CC= 40

Pu = 786.408 kN
Mu = 2.041 kN.m
e = Mu/Pu = 2.595345 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 1209.858

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.352728
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.002616
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 6
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 164 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C1
3RD FLOOR (2 GIRDER CONNECTIONS)

Given
Pd1 = 297.835 kN PD PU MY MZ
Pu1 = 356.036 kN -262.21 -325.5 0.033 0.012 ### ### 4.41 6.81
Lu = 2800 mm 297.835 356.036 -0.033 -0.012 813 ### 4.1 6.89
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 0.8365305756

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3000 1.25E+09 4.17E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 416840.27778 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 266666.66667 MY 0.033 0.033
297.835 356.036
B2 266666.66667 MZ 0.012 0.012
USE 297.835 356.036 0.045 0.045

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 3.126302
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 3.1263 cu.mm B2

B1
k = 0.90632 k1 = 0.906315
k2 = 1.006315
C1
0.4 Ec Ig
E1 = = 6.77376E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 10381.37503 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 2800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.906315 Cm = 0.2 not ok!
Pc = 10381.4 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.4191674954 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.1684 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 9.078918 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 9078.918 KN-mm = 9.078918 KN-m

Moment to be use: 9.078918 KN-m

Column Design:
CC= 58

Pu = 356.036 kN
Mu = 0.045 kN.m
e = Mu/Pu = 0.126392 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 547.7477

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.159693
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 5.77E-05
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 450 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 450
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 4 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 450
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C1
3RD FLOOR (2 GIRDER CONNECTIONS)

Given
Pd1 = 297.835 kN PD PU MY MZ
Pu1 = 342.97 kN -262.21 -312.434 0.039 0.014 -1118.1 -1452.1 3.88 6.55
Lu = 2800 mm 297.835 342.97 0.039 -0.014 812.972 1469.34 3.6 6.59
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 0.8683995685

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3000 1.25E+09 4.17E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 416840.27778 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 266666.66667 MY 0.039 0.039
297.835 342.97
B2 266666.66667 MZ 0.014 0.014
USE 297.835 342.97 0.053 0.053

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 3.126302
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 3.1263 cu.mm B2

B1
k = 0.90632 k1 = 0.906315
k2 = 1.006315
C1
0.4 Ec Ig
E1 = = 6.65822E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 10204.301575 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 2800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.906315 Cm = 0.2 not ok!
Pc = 10204.3 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.4187665105849 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.1684 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 8.745735 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 8745.735 KN-mm = 8.745735 KN-m

Moment to be use: 8.745735 KN-m

Column Design:
CC=

Pu = 342.97 kN
Mu = 0.053 kN.m
e = Mu/Pu = 0.154532 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 527.6462

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.153833
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 6.79E-05
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 450 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 450
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 4 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 450
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
C1 TOP 3
3RD FLOOR (2 GIRDER CONNECTIONS)

Given
Pd1 = 297.835 kN PD PU MY MZ
Pu1 = 316.693 kN -262.21 -286.158 0.033 0.71 -1118.1 -1414.7 3.87
Lu = 2800 mm 297.835 316.693 -0.033 0.687 812.972 1431.86 3.65
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 0.9404533728

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3000 1.25E+09 4.17E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
MU2 C1 416840.27778 fixed 1.0 MU1
Pd (kN) Pu (kN)
(kN.m) C2 416840.27778 (kN.m)
0.039 B1 266666.66667 MY 0.033
297.835 316.693
0.014 B2 266666.66667 MZ 0.71
0.053 USE 297.835 316.693 0.72

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 3.126302
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 3.1263 cu.mm B2

B1
k = 0.90632 k1 = 0.906315
k2 = 1.006315
C1
0.4 Ec Ig
E1 = = 6.41098E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 9825.3907699 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 2800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.906315 Cm = 0.2123822342 not ok!
Pc = 9825.4 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.4179624094959 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.1684 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 8.0756715 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 8075.6715 KN-mm = 8.0756715 KN-m

Moment to be use: 8.0756715 KN-m

Column Design:
58

Pu = 316.693 kN
Mu = 0.743 kN.m
e = Mu/Pu = 2.346121 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 487.22

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.142047
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.000952
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 450 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 450
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 4 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 450
Conf't zone
Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
C1

6.6
6.6

MU1 MU2
(kN.m) (kN.m)
0.033 0.033
0.71 0.687
0.72 0.743
or Mc:

CC= 58

350 mm

0.142047

0.000952

sq. mm

se

8
RY
one
mm
mm
e zone
mm
DESIGN FOR COLUMN
TOP 1 C1
3RD FLOOR (2 GIRDER CONNECTIONS)

Given
Pd1 = 297.835 kN PD PU MY MZ
Pu1 = 279.723 kN -262.21 -243.965 16.25 -0.197 ### ### 4.41 6.81
Lu = 2800 mm 297.835 279.723 -16.263 0.198 813 ### 4.1 6.89
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.0647497703

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3000 1.25E+09 4.17E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 416840.27778 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 266666.66667 MY 16.25 16.263
297.835 279.723
B2 266666.66667 MZ 0.197 0.198
USE 297.835 279.723 16.447 16.461

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 3.1263021
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 3.1263 cu.mm B2

B1
k = 0.90632 k1 = 0.906315
k2 = 1.006315
C1
0.4 Ec Ig
E1 = = 6.02505E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 9233.9095677 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 2800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.906315 Cm = 0.200340198 not ok!
Pc = 9233.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.416836307 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.1684 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 16.461 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 7132.9365 KN-mm = 7.1329365 KN-m

Moment to be use: 16.461 KN-m

Column Design:
CC= 58

Pu = 279.723 kN
Mu = 16.461 kN.m
e = Mu/Pu = 58.8475 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 430.3431

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.125464
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.021095
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 450 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 450
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 4 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 450
Conf't zone

Intermediate zone:
COLUMN TIES
A.) 16db = 256 mm
B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C1
3RD FLOOR (2 GIRDER CONNECTIONS)

Given
Pd1 = 297.835 kN PD PU MY MZ
Pu1 = 194.077 kN -262.21 -165.952 16.239 -0.201 -1118.1 -1452.1 3.88 6.55
Lu = 2800 mm 297.835 194.077 -16.253 0.202 812.972 1469.34 3.6 6.59
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.5346228559

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3000 1.25E+09 4.17E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 416840.27778 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 266666.66667 MY 16.239 16.253
297.835 194.077
B2 266666.66667 MZ 0.201 0.202
USE 297.835 194.077 16.44 16.455

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 3.1263021
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 3.1263 cu.mm B2

B1
k = 0.90632 k1 = 0.906315
k2 = 1.006315
C1
0.4 Ec Ig
E1 = = 4.90811E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 7522.1102874 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 2800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.906315 Cm = 0.2003646308 not ok!
Pc = 7522.1 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.4142507055621 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.1684 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 16.455 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 4948.9635 KN-mm = 4.9489635 KN-m

Moment to be use: 16.455 KN-m

Column Design:
CC=

Pu = 194.077 kN
Mu = 16.455 kN.m
e = Mu/Pu = 84.78594 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 298.58

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.08705
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.021087
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 450 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 450
SUMMARY
Conf't zone
ln 2700 mm 1 - 64 mm
Intermediate zone 4 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 450
Conf't zone

Intermediate zone:
COLUMN TIES
A.) 16db = 256 mm
B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
C1 TOP 3 C1
3RD FLOOR (2 GIRDER CONNECTIONS)

Given
Pd1 = 297.835 kN PD PU MY MZ
Pu1 = 191.307 kN -262.21 -286.086 1 0.012 -1118.1 -1414.7 3.87 6.56
Lu = 2800 mm 297.835 191.307 0.949 -0.006 812.972 1431.86 3.65 6.62
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.5568431892

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3000 1.25E+09 4.17E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
MU2 C1 416840.27778 fixed 1.0 MU1
Pd (kN) Pu (kN)
(kN.m) C2 416840.27778 (kN.m)
16.253 B1 266666.66667 MY 1
297.835 191.307
0.202 B2 266666.66667 MZ 0.012
16.455 USE 297.835 191.307 0.955

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 3.1263021
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 3.1263 cu.mm B2

B1
k = 0.90632 k1 = 0.906315
k2 = 1.006315
C1
0.4 Ec Ig
E1 = = 4.86546E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 7456.7391302 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 2800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.906315 Cm = 0.2225296443 not ok!
Pc = 7456.7 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.4141676163069 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.1684 ≤ 45
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 4.8783285 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 4878.3285 KN-mm = 4.8783285 KN-m

Moment to be use: 4.8783285 KN-m

Column Design:
58

Pu = 191.307 kN
Mu = 1.012 kN.m
e = Mu/Pu = 5.289927 mm 350
234
γ = = 0.668571
350
Pn = Pu/Ф = 294.3185

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.085807
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.001297
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 450 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 450
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 4 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 450
Conf't zone

Intermediate zone:
COLUMN TIES
A.) 16db = 256 mm
B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
C1

MU2
(kN.m)
0.949
0.006
1.012
CC= 58

mm
DESIGN FOR COLUMN
TOP 1 C1
3RD FLOOR (2 GIRDER CONNECTIONS)

Given
Pd1 = 297.835 kN PD PU MY MZ
Pu1 = 279.092 kN -262.21 -244.596 -0.356 16.225 ### ### 4.41 6.81
Lu = 2800 mm 297.835 279.092 0.357 -16.232 813 ### 4.1 6.89
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.0671570665

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3000 1.25E+09 4.17E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 416840.27778 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 266666.66667 MY 0.356 0.357
297.835 279.092
B2 266666.66667 MZ 16.225 16.232
USE 297.835 279.092 16.581 16.589

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 3.1263021
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 3.1263 cu.mm B2

B1
k = 0.90632 k1 = 0.906315
k2 = 1.006315
C1
0.4 Ec Ig
E1 = = 6.01803E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 9223.15627 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 2800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.906315 Cm = 0.2001928989 not ok!
Pc = 9223.2 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.4168171395 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.1684 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 16.589 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 7116.846 KN-mm = 7.116846 KN-m

Moment to be use: 16.589 KN-m

Column Design:
CC= 58

Pu = 279.092 kN
Mu = 16.589 kN.m
e = Mu/Pu = 59.43918 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 429.3723

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.125181
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.021259
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 450 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 450
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 4 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 450
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C1
3RD FLOOR (2 GIRDER CONNECTIONS)

Given
Pd1 = 297.835 kN PD PU MY MZ
Pu1 = 193.445 kN -262.21 -166.584 -0.367 16.221 -1118.1 -1452.1 3.88 6.55
Lu = 2800 mm 297.835 193.445 0.368 -16.228 812.972 1469.34 3.6 6.59
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.5396365892

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3000 1.25E+09 4.17E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05
A
Beam and Column Connections Given:
For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
C1 416840.27778 fixed 1.0 MU1 MU2
Pd (kN) Pu (kN)
C2 416840.27778 (kN.m) (kN.m)
B1 266666.66667 MY 0.367 0.368
297.835 193.445
B2 266666.66667 MZ 16.221 16.228
USE 297.835 193.445 16.588 16.596

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 3.1263021
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 3.1263 cu.mm B2

B1
k = 0.90632 k1 = 0.906315
k2 = 1.006315
C1
0.4 Ec Ig
E1 = = 4.89842E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 7507.2601883 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 2800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.906315 Cm = 0.2001928175 not ok!
Pc = 7507.3 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.4142317450782 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.1684 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 16.596 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 4932.8475 KN-mm = 4.9328475 KN-m

Moment to be use: 16.596 KN-m

Column Design:
CC=

Pu = 193.445 kN
Mu = 16.596 kN.m
e = Mu/Pu = 85.79183 mm 350 mm
234
γ = = 0.668571
350
Pn = Pu/Ф = 297.6077

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.086766
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.021268
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 101 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 450 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 450
SUMMARY
Conf't zone
ln 2700 mm 1 - 64 mm
Intermediate zone 4 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 450
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
C1 TOP 3 C1
3RD FLOOR (2 GIRDER CONNECTIONS)

Given
Pd1 = 297.835 kN PD PU MY MZ
Pu1 = 191.379 kN -262.21 -286.158 -0.003 0.71 -1118.1 -1414.7 3.87 6.56
Lu = 2800 mm 297.835 191.379 -0.018 0.692 812.972 1431.86 3.65 6.62
f'c = 28 Mpa
Ec = 24870.062324 Mpa
βdns = 1.5562574786

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 3000 1.25E+09 4.17E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 400 300 6000 1.60E+09 2.67E+05

Beam and Column Connections Given:


For A Ig/L For B Ig/L MU Non-Sway (Beam No. )
MU2 C1 416840.27778 fixed 1.0 MU1
Pd (kN) Pu (kN)
(kN.m) C2 416840.27778 (kN.m)
0.368 B1 266666.66667 MY 0.003
297.835 191.379
16.228 B2 266666.66667 MZ 0.71
16.596 USE 297.835 191.379 0.71

Solving for Pc:


0.7 ΣIgcol. (1/Lcol.)
ψA = = 3.1263021
0.35 ΣIgbeam (1/Lbeam)

0.7 ΣIgcol. (1/Lcol.)


ψB = = 1.0
0.35 ΣIgbeam (1/Lbeam) C2

ψm = smaller of ψA and ψB = 3.1263 cu.mm B2

B1
k = 0.90632 k1 = 0.906315
k2 = 1.006315
C1
0.4 Ec Ig
E1 = = 4.86657E+12
N-mm^2
1 + Bdns

π^2EI
Pc = = 7458.4476792 KN
(kLμ)^2

GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 2800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.906315 Cm = 0.2016830295 not ok!
Pc = 7458.4 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.4141697756056 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

24.1684 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 4.8801645 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 4880.1645 KN-mm = 4.8801645 KN-m

Moment to be use: 4.8801645 KN-m

Column Design:
58

Pu = 191.379 kN
Mu = 0.713 kN.m
e = Mu/Pu = 3.725592 mm 350
234
γ = = 0.668571
350
Pn = Pu/Ф = 294.4292

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.668571 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.085839
f'cAg
0.6 - 0.7 0.6 - 0.668571
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.000914
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 4
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 218 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 450 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 450
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 4 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 450
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
C1

MU2
(kN.m)
0.018
0.692
0.713
CC= 58

mm
DESIGN FOR COLUMN
TOP 1 C2
3RD FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 114.548 kN
Pu1 = 130.849 kN PD PU MY MZ -431 -589.8 1.56 -0.2
Lu = 3800 mm -127.479 -141.933 -17.172 -8.229 -774 -1187 2.89 0.42
f'c = 28 Mpa 114.548 130.849 -20.586 -9.188 562 1197 2.73 0.46
Ec = 24870.062324 Mpa
βdns = 0.8754212871

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 17.172 20.586
114.548 130.849
B1 266666.66667 B4 266666.66667 MZ 8.229 9.188
B2 379687.5 B5 379687.5 USE 114.548 130.849 25.401 29.774
B3 400000 B6 400000
C3
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam) C2

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 1.5934959
B6
B3 B B2
B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm B1

C1
k = 0.84939 k1 = 0.84939
k2 = 0.919715
B3 A B1

0.4 Ec Ig B2
E1 = = 6.63329E+12
N-mm^2 C1
1 + Bdns

π^2EI
Pc = = 6284.1561869 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.9412507557 ok!
Pc = 6284.2 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.9681286503 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 > 24
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 29.774 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 3336.6495 KN-mm = 3.3366495 KN-m

Moment to be use: 29.774 KN-m

Column Design:
CC= 40

Pu = 130.849 kN
Mu = 29.774 kN.m
e = Mu/Pu = 227.5447 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 201.3062

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.05869
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.038156
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C2 TOP 3
3RD FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 114.548 kN
Pu1 = 130.303 kN PD PU MY MZ -431 -590 1.56 -0.2
Lu = 3800 mm -127.479 -141.386 -16.902 -8.261 -774 -947 2.52 0.29
f'c = 28 Mpa 114.548 130.303 -20.282 -9.18 562 958 2.41 0.3
Ec = 24870.062324 Mpa
βdns = 0.8790895068

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 16.902 20.282
114.548 130.303
B1 266666.66667 B4 266666.66667 MZ 8.261 9.18
B2 379687.5 B5 379687.5 USE 114.548 130.303 25.163 29.462
B3 400000 B6 400000
C3
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam) C2

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959
B6 B3 B B2
B4

B5 C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm B1

C1
k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig B2
E1 = = 6.62034E+12
N-mm^2
1 + Bdns C1

π^2EI
Pc = = 6271.8887218 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.9416332903 ok!
Pc = 6271.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.96846057724 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 > 24
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 29.462 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 3322.7265 KN-mm = 3.3227265 KN-m

Moment to be use: 29.462 KN-m

Column Design:
CC= 40

Pu = 130.303 kN
Mu = 29.462 kN.m
e = Mu/Pu = 226.1038 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 200.4662

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.058445
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.037756
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C2
3RD FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 114.548 kN
Pu1 = 129.241 kN PD PU MY MZ -431 -590 1.56 -0.2
Lu = 3800 mm -127.479 -140.324 4.344 -5.513 -774 -947 2.52 0.29
f'c = 28 Mpa 114.548 129.241 6.049 -5.709 562 958 2.41 0.3
Ec = 24870.062324 Mpa
βdns = 0.8863131669

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 4.344 6.049
114.548 129.241
B1 266666.66667 B4 266666.66667 MZ 5.513 5.709
B2 379687.5 B5 379687.5 USE 114.548 129.241 9.857 11.758
B3 400000 B6 400000

Solving for Pc:


C3
0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam) C2

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959 B6 B3 B B2 B4

ψm = smaller of ψA and ψB = 1.3943 cu.mm B1 B5 C2

C1
k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig
E1 = = 6.59499E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 6247.8704446 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.9353291376 ok!
Pc = 6247.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.96185796013 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 > 24
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 11.758 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 3295.6455 KN-mm = 3.2956455 KN-m

Moment to be use: 11.758 KN-m

Column Design:
CC= 40

Pu = 129.241 kN
Mu = 11.758 kN.m
e = Mu/Pu = 90.97732 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 198.8323

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.057969
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.015068
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C2
3RD FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 114.548 kN
Pu1 = 84.383 kN PD PU MY MZ -431 -590 1.56 -0.23
Lu = 3800 mm -127.479 -95.467 26.77 -3.292 -774 -799 38.5 -25
f'c = 28 Mpa 114.548 84.383 33.548 -0.711 562 809.86 38.4 -25
Ec = 24870.062324 Mpa
βdns = 1.357477217

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 26.77 33.548
114.548 84.383
B1 266666.66667 B4 266666.66667 MZ 3.292 0.711
B2 379687.5 B5 379687.5 USE 114.548 84.383 30.062 34.259
B3 400000 B6 400000

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959 B6 B B4

ψm = smaller of ψA and ψB = 1.3943 cu.mm


B5 C2

k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig
E1 = = 5.27692E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 4999.1746261 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.9509968184 ok!
Pc = 4999.2 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.97289259161 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 > 23
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 34.259 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 2151.7665 KN-mm = 2.1517665 KN-m

Moment to be use: 34.259 KN-m

Column Design:
CC= 40

Pu = 84.383 kN
Mu = 34.259 kN.m
e = Mu/Pu = 405.9941 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 129.82

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.0378484
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.0439035
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES
A.) 16db = 256 mm
B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C2
3RD FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 114.548 kN
Pu1 = 84.93 kN PD PU MY MZ -431 -590 1.56 -0.2
Lu = 3800 mm -127.479 -96.013 26.5 -3.259 -774 -725 38 -25
f'c = 28 Mpa 114.548 84.93 33.244 -0.719 562 735 38 -25
Ec = 24870.062324 Mpa
βdns = 1.3487342517

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 26.5 33.244
114.548 84.93
B1 266666.66667 B4 266666.66667 MZ 3.259 0.719
B2 379687.5 B5 379687.5 USE 114.548 84.93 29.759 33.963
B3 400000 B6 400000

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959 B6 B B4

ψm = smaller of ψA and ψB = 1.3943 cu.mm


B5 C2

k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig
E1 = = 5.29656E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 5017.7836322 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.950487295 ok!
Pc = 5017.8 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.97243290082 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 > 23
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 33.963 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 2165.715 KN-mm = 2.165715 KN-m

Moment to be use: 33.963 KN-m

Column Design:
CC= 40

Pu = 84.93 kN
Mu = 33.963 kN.m
e = Mu/Pu = 399.894 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 130.6615

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.038094
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.043524
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES
A.) 16db = 256 mm
B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP3 C2
3RD FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 114.548 kN
Pu1 = 82.42 kN PD PU MY MZ -431 -590 1.56 -0.2
Lu = 3800 mm -127.479 -89.014 26.425 -3.247 -774 -725 38 -25
f'c = 28 Mpa 114.548 82.42 33.162 -0.055 562 735 38 -25
Ec = 24870.062324 Mpa
βdns = 1.389808299

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 26.425 33.162
114.548 82.42
B1 266666.66667 B4 266666.66667 MZ 3.247 0.055
B2 379687.5 B5 379687.5 USE 114.548 82.42 29.672 33.217
B3 400000 B6 400000

Solving for Pc: C3


0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959 B6 B B4

ψm = smaller of ψA and ψB = 1.3943 cu.mm


B5 C2

k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig
E1 = = 5.20553E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 4931.5421198 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.9573110154 ok!
Pc = 4931.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.9791297134 < 1


≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 > 23
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 33.217 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 2101.71 KN-mm = 2.10171 KN-m

Moment to be use: 33.217 KN-m

Column Design:
CC= 40

Pu = 82.42 kN
Mu = 33.217 kN.m
e = Mu/Pu = 403.0211 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 126.8

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.036968
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.042568
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497
Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25
(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES
A.) 16db = 256 mm
B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C2
3RD FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 114.548 kN
Pu1 = 105.907 kN PD PU MY MZ -431 -590 1.56 -0.2
Lu = 3800 mm -127.479 -123.438 1.212 -33.495 -774 -830 1.94 54.9
f'c = 28 Mpa 114.548 105.907 1.69 -38.271 562 840.68 1.83 54.9
Ec = 24870.062324 Mpa
βdns = 1.081590452

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 1.212 1.69
114.548 105.907
B1 266666.66667 B4 266666.66667 MZ 33.495 38.271
B2 379687.5 B5 379687.5 USE 114.548 105.907 34.707 39.961
B3 400000 B6 400000

Solving for Pc:


C3
0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959 B6 B B4

ψm = smaller of ψA and ψB = 1.3943 cu.mm


B5 C2

k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig
E1 = = 5.9763E+12N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 5661.7478589 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.9474087235 ok!
Pc = 5661.7 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.97164240173 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 > 24
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 39.961 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 2700.6285 KN-mm = 2.7006285 KN-m

Moment to be use: 39.961 KN-m

Column Design:
CC= 40

Pu = 105.907 kN
Mu = 39.961 kN.m
e = Mu/Pu = 377.3216 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 162.9338

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.047503
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.051211
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C2 TOP 3
3RD FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 114.548 kN
Pu1 = 105.902 kN PD PU MY MZ -431 -590 1.56 -0.2
Lu = 3800 mm -127.479 -123.984 0.942 -33.462 -774 -755 1.82 55
f'c = 28 Mpa 114.548 105.902 1.696 -38.27 562 766 1.73 55
Ec = 24870.062324 Mpa
βdns = 1.0816415176

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.942 1.696
114.548 105.902
B1 266666.66667 B4 266666.66667 MZ 33.462 38.27
B2 379687.5 B5 379687.5 USE 114.548 105.902 34.404 39.966
B3 400000 B6 400000

Solving for Pc:


C3
0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959 B6 B B4

B5 C2
ψm = smaller of ψA and ψB = 1.3943 cu.mm

k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig
E1 = = 5.97616E+12
N-mm^2 B2
1 + Bdns C1

π^2EI
Pc = = 5661.6089681 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.9443326828 ok!
Pc = 5661.6 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.96848711739 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 > 24
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 39.966 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 2700.501 KN-mm = 2.700501 KN-m

Moment to be use: 39.966 KN-m

Column Design:
CC= 40

Pu = 105.902 kN
Mu = 39.966 kN.m
e = Mu/Pu = 377.3866 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 162.9262

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.0475
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.051217
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C2
3RD FLOOR (3 GIRDER CONNECTIONS)

Given
Pd1 = 114.548 kN
Pu1 = 112.901 kN PD PU MY MZ -431 -590 1.56 -0.2
Lu = 3800 mm -127.479 -116.991 0.859 -33.457 -774 -755 1.82 55
f'c = 28 Mpa 114.548 112.901 1.837 -38.265 562 766 1.73 55
Ec = 24870.062324 Mpa
βdns = 1.0145880019

Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 400 300 6000 1.60E+09 2.67E+05
Beam 2 (B2) 450 300 6000 2.28E+09 3.80E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 400 300 6000 1.60E+09 2.67E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 4000 1.60E+09 4.00E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.859 1.837
114.548 112.901
B1 266666.66667 B4 266666.66667 MZ 33.457 38.265
B2 379687.5 B5 379687.5 USE 114.548 112.901 34.316 40.102
B3 400000 B6 400000

Solving for Pc:


C3
0.7 ΣIgcol. (1/Lcol.)
ψA = = 1.3943089
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
0.35 ΣIgbeam (1/Lbeam)
= 1.5934959 B6 B B4

ψm = smaller of ψA and ψB = 1.3943 cu.mm


B5 C2

k = 0.84939 k1 = 0.84939
k2 = 0.919715 B3 A B1

0.4 Ec Ig
E1 = = 6.17507E+12
N-mm^2
1 + Bdns B2
C1
π^2EI
Pc = = 5850.0498731 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa p
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.84939 Cm = 0.9422871677 ok!
Pc = 5850.0 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.96717470281 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

30.73984 > 24
Calculating for Mc:
therefore, SLENDER column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 40.102 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 2878.9755 KN-mm = 2.8789755 KN-m

Moment to be use: 40.102 KN-m

Column Design:
CC= 40

Pu = 112.901 kN
Mu = 40.102 kN.m
e = Mu/Pu = 355.1961 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 173.6938

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.05064
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.051391
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b = h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C3
3RD FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 290.12 kN
Pu1 = 347.018 kN PD PU MY MZ -431 -589.8
Lu = 3800 mm -254.495 -316.482 0.033 0.012 -747 -1141 2.89 0.31
f'c = 28 Mpa 290.12 347.018 -0.033 -0.012 541.9 1151.2 2.73 0.35
Ec = 24870.062324 Mpa
βdns = 0.8360373237
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.033 0.033
290.12 347.018
B1 379687.5 B4 379687.5 MZ 0.012 0.012
B2 533333.33333 B5 379687.5 USE 290.12 347.018 0.045 0.045
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 6.77558E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 7376.4760161 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2 not ok!
Pc = 7376.5 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.42676916585 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 8.848959 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 8848.959 KN-mm = 8.848959 KN-m

Moment to be use: 8.848959 KN-m

Column Design:
CC= 40

Pu = 347.018 kN
Mu = 0.045 kN.m
e = Mu/Pu = 0.129676 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 533.8738

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.155648
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 5.77E-05
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C3
3RD FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 290.12 kN
Pu1 = 332.509 kN PD PU MY MZ -431 -590
Lu = 3800 mm -254.495 -301.973 0.039 0.014 313 -915 2.52 0.21
f'c = 28 Mpa 290.12 332.509 0.039 -0.014 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 0.8725177364
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.039 0.039
290.12 332.509
B1 379687.5 B4 379687.5 MZ 0.014 0.014
B2 533333.33333 B5 379687.5 USE 290.12 332.509 0.053 0.053
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 6.64358E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 7232.7674233 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2 not ok!
Pc = 7232.8 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.42611976851 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 8.4789795 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 8478.9795 KN-mm = 8.4789795 KN-m

Moment to be use: 8.4789795 KN-m

Column Design:
CC= 40

Pu = 332.509 kN
Mu = 0.053 kN.m
e = Mu/Pu = 0.159394 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 511.5523

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.149141
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 6.79E-05
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C3
3RD FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 290.12 kN
Pu1 = 307.703 kN PD PU MY MZ -431 -590
Lu = 3800 mm -254.495 -277.167 0.033 0.71 313 -915 2.52 0.21
f'c = 28 Mpa 290.12 307.703 -0.033 0.687 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 0.9428572357
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.033 0.033
290.12 307.703
B1 379687.5 B4 379687.5 MZ 0.71 0.687
B2 533333.33333 B5 379687.5 USE 290.12 307.703 0.72 0.743
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 6.40305E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 6970.9112096 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2123822342 not ok!
Pc = 6970.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.4250140616 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 7.8464265 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 7846.4265 KN-mm = 7.8464265 KN-m

Moment to be use: 7.8464265 KN-m

Column Design:
CC= 40

Pu = 307.703 kN
Mu = 0.743 kN.m
e = Mu/Pu = 2.414666 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 473.3892

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.138014
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.000952
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C3
3RD FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 290.12 kN
Pu1 = 270.663 kN PD PU MY MZ -431 -589.8
Lu = 3800 mm -254.495 -237.395 16.154 -0.101 -747 -1141 2.89 0.31
f'c = 28 Mpa 290.12 270.663 -16.167 0.102 541.9 1151.2 2.73 0.35
Ec = 24870.062324 Mpa
βdns = 1.0718864418
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 16.154 16.167
290.12 270.663
B1 379687.5 B4 379687.5 MZ 0.101 0.102
B2 533333.33333 B5 379687.5 USE 290.12 270.663 16.255 16.269
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 6.00429E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 6536.789377 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2003442129 not ok!
Pc = 6536.8 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.42337367417 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 16.269 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 6901.9065 KN-mm = 6.9019065 KN-m

Moment to be use: 16.269 KN-m

Column Design:
CC= 40

Pu = 270.663 kN
Mu = 16.269 kN.m
e = Mu/Pu = 60.10796 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 416.4046

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.121401
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.020849
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C3
3RD FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 290.12 kN
Pu1 = 187.872 kN PD PU MY MZ -431 -590
Lu = 3800 mm -254.495 -162.238 16.143 -0.105 313 -915 2.52 0.21
f'c = 28 Mpa 290.12 187.872 -16.157 0.106 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 1.5442428888
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 16.143 16.157
290.12 187.872
B1 379687.5 B4 379687.5 MZ 0.105 0.106
B2 533333.33333 B5 379687.5 USE 290.12 187.872 16.248 16.263
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 4.88955E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 5323.188813 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2003689356 not ok!
Pc = 5323.2 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.41975250694 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 16.263 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 4790.736 KN-mm = 4.790736 KN-m

Moment to be use: 16.263 KN-m

Column Design:
CC= 40

Pu = 187.872 kN
Mu = 16.263 kN.m
e = Mu/Pu = 86.56426 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 289.0338

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.084266
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.020841
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C3
Given
Pd1 = 290.12 kN
Pu1 = 186.423 kN PD PU MY MZ -431 -590
Lu = 3800 mm -254.495 -277.144 1 0.012 313 -915 2.52 0.21
f'c = 28 Mpa 290.12 186.423 0.949 -0.006 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 1.5562457422
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 1 0.949
290.12 186.423
B1 379687.5 B4 379687.5 MZ 0.012 0.006
B2 533333.33333 B5 379687.5 USE 290.12 186.423 0.955 1.012
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.8618974
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.9850256
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 4.86659E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 5298.1937767 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2225296443 not ok!
Pc = 5298.2 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc
kLμ = 0.4196896811 < 1
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 45
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 4.7537865 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 4753.7865 KN-mm = 4.7537865 KN-m

Moment to be use: 4.7537865 KN-m

Column Design:
CC= 40

Pu = 186.423 kN
Mu = 1.012 kN.m
e = Mu/Pu = 5.428515 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 286.8046

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.083617
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.001297
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!

DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 1 C3
3RD FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 290.12 kN
Pu1 = 270.646 kN PD PU MY MZ -431 -589.8
Lu = 3800 mm -254.495 -237.412 -0.228 16.096 -747 -1141 2.89 0.31
f'c = 28 Mpa 290.12 270.646 0.229 -16.104 541.9 1151.2 2.73 0.35
Ec = 24870.062324 Mpa
βdns = 1.0719537699
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.228 0.229
290.12 270.646
B1 379687.5 B4 379687.5 MZ 16.096 16.104
B2 533333.33333 B5 379687.5 USE 290.12 270.646 16.324 16.333
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.861897
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.985026
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 6.0041E+12N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 6536.5769642 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2002204127 not ok!
Pc = 6536.6 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.4233729242 < 1


≤ 34-12(m1/m2) δ
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 16.333 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 6901.473 KN-mm = 6.901473 KN-m

Moment to be use: 16.333 KN-m

Column Design:
CC= 40

Pu = 270.646 kN
Mu = 16.333 kN.m
e = Mu/Pu = 60.3482 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 416.3785

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.121393
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.020931
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 2 C3 TOP 3
3RD FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 290.12 kN
Pu1 = 187.855 kN PD PU MY MZ -431 -590
Lu = 3800 mm -254.495 -162.255 -0.238 16.092 313 -915 2.52 0.21
f'c = 28 Mpa 290.12 187.855 0.239 -16.1 925 2.41 0.23
Ec = 24870.062324 Mpa
βdns = 1.5443826355
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.238 0.239
290.12 187.855
B1 379687.5 B4 379687.5 MZ 16.092 16.1
B2 533333.33333 B5 379687.5 USE 290.12 187.855 16.33 16.339
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.861897
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.985026
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 4.88929E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 5322.8964441 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2002203317 not ok!
Pc = 5322.9 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.41975176975 < 1


≤ 34-12(m1/m2) δ
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 46
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 16.339 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 4790.3025 KN-mm = 4.7903025 KN-m

Moment to be use: 16.339 KN-m

Column Design:
CC= 40

Pu = 187.855 kN
Mu = 16.339 kN.m
e = Mu/Pu = 86.97666 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 289.0077

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.084259
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.020939
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm
DESIGN FOR COLUMN
TOP 3 C3
3RD FLOOR (4 GIRDER CONNECTIONS)
Given
Pd1 = 290.12 kN
Pu1 = 186.447 kN PD PU MY MZ -431 -590
Lu = 3800 mm -254.495 -277.167 0.033 0.71 313 -915 2.52 0.2
f'c = 28 Mpa 290.12 186.447 -0.018 0.692 925 2.41 0.2
Ec = 24870.062324 Mpa
βdns = 1.5560454177
Dimension (mm)
Structure Length (mm) Ig (mm^4) Ig/L (mm^3)
Height Width
Column 1 (C1) 350 350 4000 1.25E+09 3.13E+05
Column 2 (C2) 350 350 3000 1.25E+09 4.17E+05
Column 3 (C3) 350 350 3000 1.25E+09 4.17E+05
Beam 1 (B1) 450 300 6000 2.28E+09 3.80E+05
Beam 2 (B2) 400 300 3000 1.60E+09 5.33E+05
Beam 3 (B3) 400 300 4000 1.60E+09 4.00E+05
Beam 4 (B4) 450 300 6000 2.28E+09 3.80E+05
Beam 5 (B5) 450 300 6000 2.28E+09 3.80E+05
Beam 6 (B6) 400 300 3000 1.60E+09 5.33E+05
Beam 7 (B7) 400 300 4000 1.60E+09 4.00E+05
Beam 8 (B8) 450 300 6000 2.28E+09 3.80E+05

Beam and Column Connections Given: MU Non-Sway (Beam No. )


For A Ig/L For B Ig/L MU1 MU2
Pd (kN) Pu (kN)
C1 312630.20833 C2 416840.27778 (kN.m) (kN.m)
C2 416840.27778 C3 416840.27778 MY 0.033 0.018
290.12 186.447
B1 379687.5 B4 379687.5 MZ 0.71 0.692
B2 533333.33333 B5 379687.5 USE 290.12 186.447 0.71 0.743
B3 400000 B6 533333.33333
B4 379687.5 B7 400000
C3
B8
Solving for Pc:
0.7 ΣIgcol. (1/Lcol.)
ψA = = 0.861897
0.35 ΣIgbeam (1/Lbeam)

ψB =
0.7 ΣIgcol. (1/Lcol.)
= 0.985026
B6 B B4

0.35 ΣIgbeam (1/Lbeam)


B5 C2 B4
ψm = smaller of ψA and ψB = 0.8619 cu.mm

k = 0.79235 k1 = 0.792346
k2 = 0.893095
B3 A B1

0.4 Ec Ig
E1 = = 4.86698E+12
N-mm^2 B2
1 + Bdns
C1
π^2EI
Pc = = 5298.6090111 KN
(kLμ)^2
GIVEN:
fc' = 28 Mpa Input a letter p if single curvature, if not leave it blank:
fy = 414 Mpa
Lu = 3800 mm
Dimension = 350 mm (Square) Calculate Cm:(MU2>Mu1)
Ig = 1.25E+09 mm^4 Cm = 0.60+0.4(M1/M2) ≥ 0.4
k = 0.792346 Cm = 0.2177658143 not ok!
Pc = 5298.6 kN Calculating moment magnifier "δ":
Solving for δ :
Cm
δ =
CHECKING FOR THE METHOD TO BE USE: 1 - Pu/0.75Pc

kLμ = 0.41969072155 < 1


≤ 34-12(m1/m2) δ
≤ 34-12(m1/m2) δ
r USE, 1

r = 105

28.67538 ≤ 45
Calculating for Mc:
therefore, SHORT column
Mc = δMoment to be use
CALCULATING FOR M2MIN:
M2MIN=Pu(15+0.03h) Mc = 4.7543985 KN-m
if M2min<MU2 ; use MU2
if M2min>MU2 ; use M2min
M2MIN= 4754.3985 KN-mm = 4.7543985 KN-m

Moment to be use: 4.7543985 KN-m

Column Design:
CC= 40

Pu = 186.447 kN
Mu = 0.743 kN.m
e = Mu/Pu = 3.985047 mm 350 mm
270
γ = = 0.771429
350
Pn = Pu/Ф = 286.8415

350 mm

Determine γ using Interaction diagram


from Appendix
for Kn & Rn:
γ 0.6 0.771429 0.7
ρg 0.01 0.01 0.01 Pn
Kn = = 0.083627
f'cAg
0.6 - 0.7 0.6 - 0.771429
=
0.01 - 0.01 0.01 - ρg Rn = Pne
= 0.000952
fc' Ag h

ρg = 0.01 As = ρgAg
As = 1225 sq. mm

FOR BEAM DESIGN Therefore Use


Bar dia. Ø Number of Bars Bar dia. Ø Number of Bars
16 mm 6.09574044585987
20 mm 3.90127388535032 16 8
25 mm 2.4968152866242
28 mm 1.99044585987261
32 mm 1.52393511146497

Spacing = B - 2(65) - db(((n/4)+1) - 1) = 119 mm > 25


(((n/4)+1) - 1)
therefore, OK!
DESIGN OF TIES

Confinement Zone

Smax of Ties: (smallest of )


1) S = 8 db = 128
2) S = 6(main bar di = 24dbhoop = 288
3) S = 0.2(b) = B/2 = 175
4) S = 300 = 300

ACI REQUIREMENTS Conf't zone:


1) L = ln/6 = 616.66666667 mm
2) L = b=h = 350 mm
3) L = 450 = 450 mm

Conf't zone
L = 616.6667
SUMMARY
Conf't zone
ln ### mm 1 - 64 mm
Intermediate zone 5 - 128 mm
Intermediate zone
Rest @ 256 mm

L = 616.6667
Conf't zone

Intermediate zone:
COLUMN TIES

A.) 16db = 256 mm


B.) 48dt = 576 mm
C.) least dimension of column = 350 mm

Say, S = 256 mm