WAREHOUSE
RCC FOUNDATION (1500*1500) RAFT FOUNDATIONS ARE LARGE CONCRETE SLABS WHICH CAN SUPPORT A LARGE MATERIALS USED FOR RAFT FOUNDATION CONSTRUCTION :
NUMBER OF COLUMNS AND WALLS. RAFT FOUNDATIONS ARE FORMED BY REINFORCED
CONCRETE SLABS OF UNIFORM THICKNESS THAT COVER A WIDE AREA, OFTEN THE 1- FORMWORK
2- SPACER
ENTIRE FOOTPRINT OF A BUILDING.THEY SPREAD THE LOAD IMPOSED BY A NUMBER OF
3- REINFORCEMENT
COLUMNS OR WALLS OVER THE AREA OF FOUNDATION, AND CAN BE CONSIDERED
4- CONCRETE.
TO ‘FLOAT’ ON THE GROUND AS A RAFT FLOATS ON WATER.
10038,26
ADVANTAGES OF RAFT FOUNDATIONS :
THEY ARE SUITABLE WHERE:
1- RAFT FOUNDATIONS TEND TO BE CHEAPER AND QUICKER TO USE
1- A BASEMENT IS REQUIRED. THAN TRADITIONAL FOOTINGS.
2- THE FOUNDATION AND FLOOR SLAB IS COMBINED, WHICH SAVES
2- GROUND CONDITIONS ARE POOR AND STRIP OR PAD FOUNDATIONS WOULD REQUIRE
TIME AND MATERIALS
SIGNIFICANT EXCAVATION.
3- LESS EXCAVATION IS REQUIRED
3- WHERE IT MAY BE IMPRACTICAL TO CREATE INDIVIDUAL STRIP OR PAD FOUNDATIONS 4- THEY ARE IDEAL FOR POOR GROUND CONDITION WHERE NORMAL
FOR A LARGE NUMBER OF INDIVIDUAL LOADS. IN VERY GENERAL TERMS, IF STRIP OR PAD FOOTINGS WOULD NOT COPE WELL AS THEY CANNOT SPREAD THE
FOUNDATIONS WOULD COVER 50% OR MORE OF THE FLOOR AREA, THEN A RAFT MAY BE LOAD AS EFFECTIVELY.
MORE APPROPRIATE. 5- RAFT FOUNDATIONS CAN REDUCE DIFFERENTIAL SETTLEMENT,
PLAN RAFT FOUNDATIONS CAN BE FAST AND INEXPENSIVE TO CONSTRUCT, AS THEY TEND NOT
WHERE SETTLEMENT OCCURS AT DIFFERENT RATES ACROSS THE
GROUND SURFACE OF THE BUILDING, WHICH REDUCES CRACKING
AND OTHER MORE SERIOUS PROBLEMS.
SC-1:100 TO REQUIRE DEEP EXCAVATIONS COMPARED TO STRIP OR PAD FOUNDATIONS AND THEY
MAY USE LESS MATERIAL AS THEY COMBINE THE FOUNDATION WITH THE GROUND SLAB.
DISADVANTAGES OF RAFT FOUNDATIONS :
SOLID RAFT FLAT SLAB FOUNDATION
HOWEVER, THEY TEND TO BE LESS EFFECTIVE WHERE STRUCTURAL LOADS ARE
1- THE MAIN DISADVANTAGE IS THAT THEY CAN PRONE TO EDGE
FOCUSED ON IN A FEW CONCENTRATED AREAS, AND THEY CAN BE PRONE TO EROSION EROSION IF THEY ARE NOT TREATED PROPERLY.
AT THEIR EDGES. 2- THEY ARE NOT EFFECTIVE IS THE LOAD OF THE BUILDING IS GOING
TO BE FOCUSED ON A SINGLE POINT, ALTHOUGH THIS IS RARE IN
THE CONCRETE RAFT TENDS TO INCLUDE STEEL REINFORCEMENT TO PREVENT DOMESTIC CONSTRUCTION, SO THIS ISN’T GENERALLY OF CONCERN.
CRACKING, AND MAY INCORPORATE STIFFENING BEAMS OR THICKENED AREAS TO
PROVIDE ADDITIONAL SUPPORT FOR SPECIFIC LOADS, FOR EXAMPLE, BELOW INTERNAL
WALLS OR COLUMNS.
DETAILED PLAN
SC-1:20
TOP BOTTOM
REINFORCEMENT REINFORCEMENT
5000 5000
LEAN CONCRETE
STIRRUPS 8 MM DIA
COLUMN REINFORCEMENT 16 MM DIA
CHAIR
650
10038,26
12 MM DIA BARS 12 MM DIA BARS
PLAN
SC-1:100
DETAILED PLAN
SC-1:20
SOLID RAFT FOUNDATION PLAN ( TOP BOTTOM
PEDESTAL )
REINFORCEMENT REINFORCEMENT
5000 5000
G.L G.L
LEAN CONCRETE
2170
PEDESTAL REINFORCEMENT 12 MM THK DIA
8683
COVER BAR 12 MM DIA
STIRRUPS 12 MM THK DIA
COLUMN REINFORCEMENT
CHAIR
650
12 MM DIA BARS
12 MM DIA BARS
10038,26
8 MM DIA STIRRUPS
8 MM DIA STIRRUPS
PLAN
4961,74
SC-1:100
DETAILED PLAN
SC-1:20
TOP BOTTOM
REINFORCEMENT REINFORCEMENT
500
400
500
400
G.L G.L
STIRRUPS 8MM THK DIA
COLUMN REINFORCEMENT 16 MM THK DIA
CHAIR