NOTES

1. ALL DIMENSION ARE GIVEN IN MILLIMETERS


2. THE INTERLOCK PAVERS/ TUFF TILES SHALL BE LAID LEVELED
WITH EFFECTIVE SLOPE TO AVOID ACCUMULATION OF RAIN
WATER.
3. KERB STONES WHERE REQUIRED SHALL BE AS PER DETAILS
MENTIONED IN DRAWINGS AND TO BE LAID IN 1:3 C/S MORTAR .
2500 RECTANGULAR INTERLOCK 4. 150mm OF EXISTING GROUND SHALL BE CLEARED/SCARIFIED
PIGMENTED
(SEE DETAIL -A) FOR REMOVING OF VEGETATION AND LOOSE STRATA.
5. SUB-GRADE SHALL BE WELL COMPACTED PRIOR TO PROVIDING
SAND CUSHION .
6. FINE AGGREGATE SHALL BE FREE FROM ALL KINDS OF LUMPS,
VEGETATION AND OTHER ORGANIC MATTERS.
INTERLOCK GREY COLOR (SEE
DETAIL-A)
7. AFTER LAYING THE PAVERS/ TUFF TILES SPREAD A THIN
TYP. UNIFORM LAYER OF DRY MEDIUM OR COARSE SAND
2500 X 2500
REPEATEDLY OVER THE PAVING SURFACE FOR SEALING OF
2500 PANEL JOINTS.
8. AFTER PROVIDING SAND FILLING A LIGHT VIBRATING PLATE
TYP. COMPACTOR SHALL BE USED IN DIFFERENT DIRECTIONS
MAKING A COUPLE OF PASSES TO VIBRATE AND SETTLE THE
SEALING SAND.
9. THE COMPACTION OF ANY MATERIAL (SUB BASE, EARTH OR
SAND ) SHALL BE DONE BY LAYING LAYERS OF MATERIAL OF
DETAIL-A NOT MORE THAN 150MM THICKNESS. THE FIRST LAYER SHALL
BE LAID AND COMPACTED EFFECTIVELY BY PROPER
COMPACTION EQUIPMENT BY ALTERNATIVELY COMPACTING
AND WETTING THE MATERIAL . THE LAYERS SHALL BE LAID AND
COMPACTED UPTO MINIMUM 95% PROCTOR DENSITY.
10. ALL MATERIAL AND WORKMANSHIP SHALL BE ACCORDING TO
STANDARD SPECIFICATIONS AS LAID DOWN IN WAPDA C.S.R.
100 50 LATEST EDITION.
PLAN OF 2500 mm X 2500 mm PANEL IN 11. THIS DRAWING/ DOCUMENT IS THE PROPERTY OF DESIGN
PAVED AREA NTDC, ANY PART THEREOF OR WHOLE CANNOT BE
SCALE 1:50 REPRODUCED ELECTRONICALLY OR OTHERWISE OR BECOME
A PART OF ANY RETRIEVAL SYSTEM WITHOUT PRIOR
450
PERMISSION OF DESIGN NTDC.
HIGH LOAD BEARING
12. THIS DRAWING / DOCUMENT CAN ONLY BE USED FOR SPECIFIC
INTERLOCKING PAVERS
(7000 PSI)
PURPOSE/SITUATION/ LOCATION FOR WHICH IT HAS BEEN
APPROVED/ ISSUED.
80 mm TOUGH PAVERS
13. COMPRESSIVE STRENGTH OF PAVER PATH IS 7000PSI
(7000 psi) 150
100 mm STONE DUST POWDER KERB STONE
(600MM LENGTH)
WELL COMPACTED 300 mm
SUB-BASE COURSE LAID IN
150MM THICK LAYER

WELL COMPACTED 600


mm EARTH FILL LAID IN
150MM THICK LAYER

C.E.
NATIONAL TRANSMISSION & DESPATCH COMPANY DESIGN
(NTDC)

MUHAMMAD
DRAWN
WELL COMPACTED
SECTION A-A SALEEM PAVED AREA
EXISTING N.S.L CHECKED
BY:
FARID BARKI
DETAILS FOR
ASSTT:
MANAGER
MARAYAM
MANSHA
A-TYPE STORE AT
DY.
FARID BARKI
KOTRI
MANAGER

PAPER
SHEET SCALE:-
MANAGER MUHAMMAD AZIZ SIZE:- DATED: 16/10/2020
01 OF 01 N.T.S
IS0-A3
D.M M CHIEF
DATE REVISIONS IMRAN RASHID DWG. NO. PDW/TV-487
ENGINEER