You are on page 1of 12

Page 1 of 12

Isolated Footing Design(ACI 318-11) - Metric


Footing No. Group ID Foundation Geometry
- - Length Width Thickness
1 1 1.70m 1.70m 0.30m

Footing No. Footing Reinforcement Pedestal Reinforcement


- Bottom Reinforcement(Mz) Bottom Reinforcement(Mx) Top Reinforcement(Mz) Top Reinforcement(Mx) Main Steel Trans Steel
1 10 - 12 mm 10 - 12 mm N/A N/A 32 - 22 mm 10 mm @ 300 mm

Isolated Footing 1
1.7 m 2m

0.7 m

Elevation 0.3 m

X 0.85 m

1.1 m

Z
1.7 m

1.1 m
0.85 m

1.7 m

Plan

Input Values

Footing Geomtery

Calculate Dimension with user


Design Type : specified minimums as starting
value
Minimum Footing Length - X(Fl) : 1700.00 mm
Minimum Footing Width - Z (Fw) : 1700.00 mm
Footing Thickness (Ft) : 300.00 mm
Eccentricity along X (Oxd) : 0.00 mm
Eccentricity along Z (Ozd) : 0.00 mm

Column Dimensions

Column Shape : Rectangular

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 2 of 12

Column Length - X (Dcol) : 0.30 m


Column Width - Z (Bcol) : 0.30 m

Pedestal

Include Pedestal : Yes


Pedestal Shape : Rectangular
Pedestal Height (Ph) : 1.70 m
Pedestal Length - X (Pl) : 1.10 m
Pedestal Width - Z (Pw) : 1.10 m

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 25.00 kN/m3


Strength of Concrete : 30.00 N/mm2
Yield Strength of Steel : 414.00 N/mm2
Minimum Bar Size : 12 mm
Maximum Bar Size : 16 mm
Top Footing Minimum Bar Size : 12 mm
Top Footing Maximum Bar Size : 16 mm
Pedestal Minimum Bar Size : 6 mm
Pedestal Maximum Bar Size : 22 mm
Minimum Bar Spacing : 150.00 mm
Maximum Bar Spacing : 175.00 mm
Pedestal Clear Cover (P, CL) : 75.00 mm
Bottom Footing Clear Cover (F, CL) : 75.00 mm

Soil Properties

Soil Type : Cohesive Soil

Unit Weight : 17.90kN/m3

Base Value of Soil Bearing Capacity : 488.00kPa

Multiplying factor for soil bearing capacity for ultimate


: 2.00
loads

Soil Bearing Capacity Type : Gross Bearing Capacity

Soil Surcharge : 0.00kN/m2

Height of Soil above Footing : 700.00mm

Type of Depth : Fixed Top

Cohesion : 0.00kN/m2

Bearing Capacity Input Method : Fixed Bearing Capacity

Minimum Percentage of Slab area in Contact for Service


: 0.00
Loads

Minimum Percentage of Slab area in Contact for


: 0.00
Ultimate Loads

Sliding and Overturning

Coefficient of Friction : 0.50


Factor of Safety Against Sliding : 1.50
Factor of Safety Against Overturning : 1.50

Global Settings

Top Reinforcement Option : Calculate only when foundation is subjected to uplift forces
Concrete Design Option : Net Pressure(Gross Pressure - Self Weight Pressure)

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 3 of 12

Top Reinforcement Factor : 1.00

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 1.70 m


Initial Width (Wo) = 1.70 m

Load Combinations

Load Combination/s- Service Stress Level


Load Load Soil Self
Combination Load Combination Title Combination Bearing Weight
Number Factor (a) Factor (b) Factor (c)
a - Value specified in the Load Safety Factor table
b - Value specified in the Pile/Soil Bearing Capacity Factors table
c - Value specified in the Apply Self Weight and Dead Weight Factor table
101 SL:1.000 x DL 1.00 1.00 1.00
131 SL:0.600 x DL 1.00 1.00 0.60
1 DL 1.00 1.00 1.00

Load Combination/s- Strength Level


Load Load Soil Self
Combination Load Combination Title Combination Bearing Weight
Number Factor (a) Factor (b) Factor (c)
a - Value specified in the Load Safety Factor table
b - Value specified in the Pile/Soil Bearing Capacity Factors table
c - Value specified in the Apply Self Weight and Dead Weight Factor table
201 UL:1.400 x DL 1.00 1.00 1.40
202 UL:1.200 x DL 1.00 1.00 1.20
226 UL:0.900 x DL 1.00 1.00 0.90
1 DL 1.00 1.00 1.00

Applied Loads on Top of Pedestal


Before consideration of self weight and load safety factor table

Moments are about the center of footing / pile cap (does not include moments caused by lateral loads)
For the loads shown in this table, the sign convention is the same as that for JOINT LOADS in STAAD.Pro when global Y is the vertical axis.

Applied Loads from Column - Service Stress Level


Fy
(kN)
Fx Fz Mx Mz
Load Case Downwards is
(kN) (kN) (kNm) (kNm)
negative Upwards
is positive
101 0.00 -152.70 -9.72 0.00 0.00
131 0.00 -91.62 -5.83 0.00 0.00
1 0.00 -152.70 -9.72 0.00 0.00

Applied Loads from Column - Strength Level


Fy
(kN)
Fx Fz Mx Mz
Load Case Downwards is
(kN) (kN) (kNm) (kNm)
negative Upwards
is positive
201 0.00 -213.78 -13.61 0.00 0.00
202 0.00 -183.24 -11.66 0.00 0.00
226 0.00 -137.43 -8.75 0.00 0.00
1 0.00 -152.70 -9.72 0.00 0.00

Reduction of force due to buoyancy = 0.00 kN

Effect due to adhesion = 0.00 kN

2
Area from initial length and width, Ao = Lo X W o = 2.89 m

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 4 of 12

2
Min. area required from bearing pressure, Amin = 0.63 m

Note: Amin is an initial estimation considering self-weight, axial load and moment against factored bearing capacity.

Final Footing Size

Length (L2) = 1.70 m Governing Load Case : # 101


Width (W2) = 1.70 m Governing Load Case : # 101
Depth (D2) = 0.30 m
Depth is governed by Ultimate Load Case
(Service check is performed with footing thickness requirements from concrete check)

Area (A2) = 2.89 m2


Final Pedestal Height = 1.70 m
Final Soil Height = 0.70 m
Foundation Self Weight = 73.10 kN
Soil Weight On Top Of Footing = 21.05 kN

Gross Pressures at 4 Corners


Please note that pressures values displayed in tables below are calculated after dividing by soil bearing factor

Pressure Pressure Pressure Area of


Pressure Gross
at top at bottom at bottom footing in
Load Case / at top left Bearing
right right left uplift (Au)
Combination corner Capacity
corner corner corner 2
(kN/m2) (m ) (kN/m2)
(kN/m2) (kN/m2) (kN/m2)

101 109.1553 109.1553 61.6731 61.6731 0.00 488.0000

101 109.1553 109.1553 61.6731 61.6731 0.00 488.0000

101 109.1553 109.1553 61.6731 61.6731 0.00 488.0000

101 109.1553 109.1553 61.6731 61.6731 0.00 488.0000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero and the pressure
will be redistributed to remaining corners.

Summary of Adjusted Gross Pressures at four Corners

Pressure at Pressure at Pressure at Pressure at Gross


top left top right bottom bottom left Bearing
Load Case / corner corner right corner corner Capacity
Combination (kN/m2) (kN/m2) (kN/m2) (kN/m2) (kN/m2)

101 109.1553 109.1553 61.6731 61.6731 488.0000

101 109.1553 109.1553 61.6731 61.6731 488.0000

101 109.1553 109.1553 61.6731 61.6731 488.0000

101 109.1553 109.1553 61.6731 61.6731 488.0000

Stability Check

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 5 of 12

Sliding Force 1.7 m 2m

0.7 m
.

Frictional Force 0.3 m

Factor of safety against


- Factor of safety against sliding
overturning

Load
Along X- Along Z- Required About X- About Z- Required
Case Resultant
Direction Direction FOS Direction Direction FOS
No.

101 N/A 12.70 12.70 1.50 10.79 N/A 1.50

131 N/A 12.70 12.70 1.50 10.79 N/A 1.50

1 N/A 12.70 12.70 1.50 10.79 N/A 1.50

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : N/A


Governing Disturbing Force : N/A
Governing Restoring Force : N/A
Minimum Sliding Ratio for the Critical Load Case : N/A
Critical Load Case for Overturning about X-Direction : 101
Governing Overturning Moment : -19.44 kNm
Governing Resisting Moment : 209.82 kNm
Minimum Overturning Ratio for the Critical Load Case : 10.79

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 101


Governing Disturbing Force : -9.72 kN
Governing Restoring Force : 123.42 kN
Minimum Sliding Ratio for the Critical Load Case : 12.70
Critical Load Case for Overturning about Z-Direction : N/A
Governing Overturning Moment : N/A
Governing Resisting Moment : N/A
Minimum Overturning Ratio for the Critical Load Case : N/A
Critical Load Case And The Governing Factor Of Safety For Sliding Along Resultant Direction
Critical Load Case for Sliding along Resultant Direction : 101
Governing Disturbing Force : 9.72 kN
Governing Restoring Force : 123.42 kN
Minimum Sliding Ratio for the Critical Load Case : 12.70

Compression Development Length Check


Development length calculation skipped as column reinforcement is not specified in input (Column Dimension Task Pane)

Ultimate Gross Pressures


The base pressures reported in this table do not include the effect of buoyancy. However, the area of footing in contact includes the effect of
buoyancy (if any).

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 6 of 12

Area of
Load Case / Pressure at Pressure at Pressure at
Pressure at footing in
Load top right bottom right bottom left
top left corner Contact with
Combination corner corner corner
(kN/m2) soil (Au)
ID (kN/m2) (kN/m2) (kN/m2) 2
(m )

201 152.8174 152.8174 86.3424 86.3424 2.89

202 130.9864 130.9864 74.0077 74.0077 2.89

226 98.2398 98.2398 55.5058 55.5058 2.89

1 109.1553 109.1553 61.6731 61.6731 2.89

Minimum Required Contact Area for Ultimate Loads : 0.00 m2

Actual Area in Contact for all ultimate load cases exceeds the minimum required. Hence Safe

Gross Bearing Capacity for Ultimate Loads : 976.00 kN/m2

Maximum Corner Pressure from all ultimate load cases is less than the allowable. Hence Safe

Shear Calculation

Punching Shear Check

X 0.85 m

Z 0.105 m
0.85 m

Plan
Total Footing Depth, D = 0.30m
Calculated Effective Depth, d = D - Ccover - 1 * db = 0.21 m
For rectangular column, = Bcol / Dcol = 1.00

Effective depth, d, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 142.12kN, Load Case # 201

From ACI Cl.11.11.2.1, bo for


= 5.25 m
column=

Equation 11-31, Vc1 = = 3125.07 kN

Equation 11-32, Vc2 = = 1842.23 kN

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 7 of 12

Equation 11-33, Vc3 = = 2022.23 kN

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 1381.68 kN


0.75 X Vc > Vu hence, OK

One-Way Shear Along X

(Shear Plane Parallel to Global X Axis)

X 0.85 m

0.09 m

0.85 m

0.09 m

Plan
From ACI Cl.11.2.1.1, Vc = = 327.66 kN

Distance of critical section from top left corner


along Z, DZ = = 0.09 m

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance d from the face of the column caused by bending about the X axis.

From above calculations, 0.75 X Vc = 245.75 kN

Critical load case for Vux is # 201 = 21.33 kN

0.75 X Vc > Vux hence, OK

One-Way Shear Along Z

(Shear Plane Parallel to Global Z Axis)

X 0.85 m

0.09 m 0.09 m
0.85 m

Plan
From ACI Cl.11.2.1.1, Vc = = 327.66 kN

Distance of critical section from top left corner along


X, DX = = 0.09 m

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance d from the face of the column caused by bending about the Z axis.

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 8 of 12

From above calculations, 0.75 X Vc = 245.75 kN

Critical load case for Vuz is # 201 = 16.07 kN

0.75 X Vc > Vuz hence, OK

Flexure About Z-Axis

Design For Bottom Reinforcement Parallel to X Axis

10 - 12 mm

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by
Salmon and Wang (Ref. 1)

Critical Load Case # 201

The strength values of steel and concrete used in the formulae are in Mpa

Bars parallel to X Direction are placed at bottom


Effective Depth d = 0.21 m
Factor from ACI Cl.10.2.7.3 =
= 0.83

From Appendix B 8.4.2, = = 0.03034

From Appendix B 10.3.3, = = 0.02275

From ACI Cl. 7.12.2, = = 0.00200

From Ref.1, Eq. 3.8.4a, constant m = = 16.24

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is performed at the face


= 0.30 m
of the column at a distance, Dx =

Ultimate moment = = 7.56 kNm

Nominal moment capacity, Mn = = 8.40 kNm

(Based on effective depth) Required = = 0.00028

(Based on gross depth) x d / Depth = 0.00019


Since ρ < ρmin, select ρ= ρmin ρmin Governs
Area of Steel Required, As = = 1020.00 mm2

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 9 of 12

Selected bar Size = 12 mm


Minimum spacing allowed (Smin) = 150.00mm
Selected spacing (S) = 170.89mm
Smin<= S <= Smax and selected bar size < selected maximum bar size...
The reinforcement is accepted.
According to ACI 318 Clause No- 10.6.4 1st
Max spacing for Cracking Consideration = 197.89mm

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

12 mm @ 170mm o.c.

Required development length for bars = = 0.44 m

Available development length for bars,DL = = 0.22 m

Try bar size 12 mm Area of one bar = 113.10 mm2

Number of bars required, Nbar = = 10

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1130.97 mm2
d= D - Ccover - 0.5 X (dia. of = 0.21 m
one bar)

Reinforcement ratio, = = 0.00321

From ACI Cl.7.6.1, minimum req'd clear distance between bars


Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 150.00mm
Provided Steel Area / Required Steel Area = 1.11

Flexure About X-Axis

Design For Bottom Reinforcement Parallel to Z Axis

10 - 12 mm

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete Design (5th ed.) by
Salmon and Wang (Ref. 1)

Critical Load Case # 201

The strength values of steel and concrete used in the formulae are in Mpa

Bars parallel to X Direction are placed at bottom


Effective Depth d = 0.21 m
Factor from ACI Cl.10.2.7.3 = = 0.83

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 10 of 12

From Appendix B 8.4.2, = = 0.03034

From Appendix B 10.3.3, = = 0.02275

From ACI Cl. 7.12.2, = = 0.00200

From Ref.1, Eq. 3.8.4a, constant m = = 16.24

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is performed


at the face of the column at a distance, Dz = 0.30 m
=

Ultimate moment = = 9.80 kNm

Nominal moment capacity, Mn = = 10.89 kNm

(Based on effective depth) Required = = 0.00036

(Based on gross depth) x d / Depth = 0.00025


Since ρ < ρmin, select ρ= ρmin ρmin Governs
Area of Steel Required, As = = 1020.00 mm2

Selected Bar Size = 12 mm


Minimum spacing allowed (Smin) = 150.00mm
Selected spacing (S) = 170.89mm
Smin<= S <= Smax and selected bar size < selected maximum bar size...
The reinforcement is accepted.
According to ACI 318 Clause No- 10.6.4 3rd
Testing.... Max spacing for Cracking Consideration = 197.89mm

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

12 mm @ 170mm o.c.

Required development length for bars


= 0.44 m
=

Available development length for bars,


= 0.22 m
DL =
Try bar size 12 mm Area of one bar = 113.10 mm2

Number of bars required, Nbar= = 10

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1130.97 mm2
d= D - Ccover - 1.5 X (dia. of 0.21 m
=
one bar)

Reinforcement ratio, = = 0.00321

From ACI Cl.7.6.1, minimum req'd clear distance between bars


Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 150.00mm
Provided Steel Area / Required Steel Area = 1.11

Pedestal Design

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 11 of 12

The bar sizes reported in the output below for the pedestal design are based on the table titled ASTM STANDARD REINFORCING BARS, Appendix E of ACI 318M-11 (The
Metric version of the 2011 edition of ACI 318). They are not from the same bar library that has been used in the calculations presented above for the design of this
footing. The next version of the program will use bars from a single library for the design of both components.

Pedestal at Support No. Axial Capacity Ratio Flexural Capacity Ratio % of Main Steel Main Reinforcement Links
1 0.01 0.01 1.02 32-#22 10 @ 300mm

Longitudinal Reinforcement Details

Area of Longitudinal Bars = 12386.56 sq.mm


Number of Bars and Bar Dia = 32-#22
Longitudinal Steel Percentage = 1.02
Flexure - Governing Load Case Details
Governing Load Case Number = 201
Critical Location = Bottom

Shear - Governing Load Case Details


Critical Load Case for Shear Along X = 226
Critical Load Case for Shear Along Z = 226

Transverse Stirrups Details

Rebar Links = 10 @ 300 mm


No. of Legs in X direction = 9
No. of Legs in Z direction = 9

Capacity Ratios

Flexural Capacity Ratio = 0.01


Axial Capacity Ratio = 0.01

Material Take Off


Footing Reinforcement

Direction Size Number Length (m) Weight (kgf)

Along Z on Bottom
12 mm 10 15.50 13.77
Face

Along X on Bottom
12 mm 10 15.50 13.77
Face

Along Z on Top
N/A N/A N/A N/A
Face

Along X on Top
N/A N/A N/A N/A
Face

Total Reinforcement Weight : 27.54 kgf

Concrete

- Length Width Thickness Weight

Footing 1.70m 1.70m 0.30m 21.67kN

Pedestal 1.10m 1.10m 1.70m 51.42kN

Total Concrete Weight : 73.10 kN

Soil Excavation

Pad Depth : 1.00 m


Pad Slope (a : b) : 1 : 1 (Assumed)
Side Distance, s : 0 (Assumed)
Excavation Volume : 7.62 m3

Backfill Volume : 4.70 m3

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021
Page 12 of 12

file:///C:/Users/HP/Documents/osas-part/40in-pipesuppportpad/40inpipesupport/Reports/C... 6/21/2021

X 0.85 m
1.1 m
Z
1.7 m 2m
1.7 m

1.1 m
0.85 m

0.7 m
1.7 m
0.3 m
Plan

Print Calculation Sheet


0.85 m
Elevation
BOTTOM 10 - 12 mm
Dimensions (m) Reinforcement

TOP N/A
L B D AstX(T) AstZ(T) AstX(B) AstZ(B)
Foundation
0.85 m

1.7 m 1.7 m 0.3 m N/A N/A 10 - 12 mm 10 - 12 mm


l b h Main Reinforcement Trans Reinforcement
TOP N/A Pedestal
1.1 m 1.1 m 1.7 m 22 mm - 32 10 mm @ 300 mm
BOTTOM 10 - 12 mm