Classification: Tasnee - General Information #

Record No. 18-GM-4C


MAGNETIC PARTICLE EXAMINATION CHECK SHEET (A)
Rev. 0
磁粉探傷検査記録 (A) Page No. 1 of 1

Customer Inspection Date.
Advanced Petrochemical Company 1/9/2021
注文主 検査日
Order / Item Inspector
1166 / C-0659 M. Al Ramel
オーダ/アイテム 検査員
Drawing No. Inspector
790-26965 Himanyu
図面番号 検査員
Cust.Equip.No Assistant
2-K-2001LP2 Hamza
客先機番 補助員
Job Name Assistant
Refurbishment after TA
工事名称 補助員
Rotor S/N
L5-768
シリアルナンバー
①Check point before every inspection work.

Date 01/09/2021

1.Dark curtain is applied before inspection. Yes

2.Rotor is put on the turning roller. Yes

3.Inspection facility is tested by dummy crack. Yes

4.Test positioan is suitable for inspection. Yes

5.Black light is good for use. Yes

6.Inspection style is comfortable for work. Yes

7.Marking on rotor is applied. Yes

②Check the inspection area after finished inspection.


7Ist
th
Inlet
Inlet 1st Outlet 2nd Inlet 2nd Outlet 3rd Inlet 3rd outlet

Please attach the rotor photograph.

Thrust
Side 3
1 2

③Put the inspected area after finish the day work.

Date Inspection area Judge Inspector

1/9/2021 Impeller 1st Stage Inet  Crack Al Ramel / Himanyu

1/9/2021 Impeller 1st Stage Outlet Accept Al Ramel / Himanyu

1/9/2021 Impeller 2nd Stage Inlet Accept Al Ramel / Himanyu

1/9/2021 Impeller 2nd Stage Outlet Accept Al Ramel / Himanyu

1/9/2021 Impeller 3rd Stage Inlet Accept Al Ramel / Himanyu

1/9/2021 Impeller 3rd Stage Outlet Crack Al Ramel / Himanyu

Approved by Hayat Khan

MITSUBISHI POWER Inspector


/QA Department
Standard Form No.
三菱日立パワーシステムズグループ 検査官
Classification: Tasnee - General Information #

MITSUBISHI POWER Inspector


/QA Department
三菱日立パワーシステムズグループ 検査官

Examiner / 検査員 Approved by / 承認 Reviewed by / 審査 Approved by / 承認 Reviewed by/記録確認 Witnessed by/立会


Mohammed Al Ramel Hayat Khan MCOSA
Himanyu Rafiq
Qualification / 資格
NDT Level Ⅱ