Professional Documents
Culture Documents
1 Core drilling (not wash boring) 3 borehole @ 30 m 90 area Hotel Guest Wing 58.0 21.0
2 borehole @ 30 m 60 area Hotel Guest Wing with Sky Villas 38.0 14.0
4 Cone penetration test (CPT / sondir) point 3 area Hotel Guest Wing
2.5 ton capacity point 2 area MICE
point 2 area Hotel Guest Wing - Phase 2
point 2 area Hotel Managed retail - F+B
point 2 area Main Resort pool
point 2 area Hotel Guest Wing with Sky Villas
point 3 area Beach Villas
16
7.1 Index properties test set 80 including Atterberg limits & grainsize
analysis
7.2 Unconfined compression test test 22
2 clayey soil samples from each borehole (area
1 bangunan)
7.3 Triaxial CU test 12 1 clayey soil samples from each borehole (area main resort
3 pool)
7.4 Consolidation test test 22 2 soil samples (area hotel guest wing, phase 2, hotel guest with
sky)
7.5 Unconfined compression test on rock test 36
3 soil samples (slope area)
10 SSRA LS
- CU Triaxial diuji dengan effective confining pressure di bawah tegangan efektif horizontal yang ada dilapangan;
yakni sekitar 0.65 x s'v =15 s/d 60 kPa
s'v tergantung pada kedalaman sample yang akan ditest
- uji konsolidasi sampai tegangan 2.5 x (tegangan effective lapangan + tambahan beban raft ekivalen dari struktur atas)
akan ditentukan kemudian oleh Konsultan