OMICRON PTL
User Manual
V1.000
Content
1. General ..................................................................................................................................................3
2. Software and Hardware Requirements ...............................................................................................3
3. Hardware ................................................................................................................................................4
4. Functional Range...................................................................................................................................5
5. XRIO Converter ......................................................................................................................................6
6. Specific Protection Tests ......................................................................................................................6
1. General
This user manual describes details of testing ZIV IDV-L relays with the OMICRON
Protection Test Template (PTT). General information on the usage of OMICRON
Protection Testing Library items can be found in the OMICRON PTL user manual.
• Control Center
• Diff Configuration
• Diff Trip Time Characteristic
• Diff Operating Characteristic
• Diff Harmonic Restraint
• Overcurrent
• Ramping
• State Sequencer
A CMC test set with six current outputs is required. A CMS 356 current amplifier may be additionally
required for testing with higher currents e.g. relays with 5A current measuring inputs.
3. Hardware
There are multiple possibilities of wiring a ZIV IDV-L relay to a CMC test set. The advised connections for
testing side 1 and 2 are shown in Figure 1 and for side 1 and 3 in Figure 2. These connections are the
default settings in the HardwareConnection
Configuration ofDiagram
the PTT. ZIV IDV-L
Thermal Constant
Switched
IC Side 1
IA Side 1
IB Side 1
N Side 1
N Side 2
Thermal Constant
Switched
IC Side 1
IA Side 1
IB Side 1
N Side 1
Trip Side 2
Trip Side 3
Trip Side 1
N Side 3
4. Functional Range
Supported functions:
• Differential Protection for two- or three-winding transformer applications
• Differential Protection – Harmonic blocking for 2nd and 5th
• Overcurrent Protection, Phases
• Overcurrent Protection, Neutral
• Thermal Image Protection
• Directional Unit
• Overcurrent Protection, Ground
• Overcurrent Protection, Negative Sequence
• Voltage Restrained Overcurrent
• Voltage Protection
• Frequency Protection
• Rate of Frequency Change Protection
• Breaker Failure Protection
• Breaker Supervision
• Hot Stop Thermal Image
• Current Transformer Supervision
• Cold Load Pick-Up
• Saturation Detection
• Overexcitation Protection
• Fuse Failure
• Overload Protection
5. XRIO Converter
The Test Object already contains the ZIV IDV-L XRIO Converter, which includes setting parameters of
the modelled protection relay. The setting parameters are built as an image of the ZIVercomPlus 2.9.3.0
software. General information about the converter structure can be found in the OMICRON PTT user
manual.
At this point the specifics of the section Additional Information is described. The
Transformer Information block includes parameters for the Nominal Voltage of each side and the
Nominal Power of the transformer. These values should be adapted for having these values in the test
protocol.