FAQ SV02-380-02-002E 1/3

Machine Model: NMV5000DCG


Title: NMV5000DCG Adjustment of Tool clamp detection switch
Objective: MSX-701, MSX-711
Publication: Y/M/D 2007/11/15 Written by France T/C R. Weste

Unclamp cylinder

<Tool clamp cycle>

c Tool clamp command


d Solenoid valve YV701 comes OFF
Hydraulic circuit is open

e Drawbar move back by the Belleville spring force

f Clamping timer TM120 is starting


(Standard values is set to 0.176secondes)

g After TM120 tool clamp confirmation switches


(SQ123 and SQ124) detect the status
If both switches is ON = Clamp with tool

h After TM120 output Y4.7 who pilot the tool clamp


Solenoid YV700 is activate
DOG
i The unclamp cylinder return to clamp position

j SQ121 is activate, tool unclamp confirmation

Proximity switches (SQ121, SQ123, and SQ124)


Part number : E66443A01
Type : FL7M-2J6HD-CN1Z
(YAMATAKE)

Drawbar unclamp Drawbar clamp with tool Drawbar clamp


Dog position
SQ121 - X12.3 SQ123 - X12.4 SQ124 - X12.5
Clamp ON OFF OFF
Empty clamp OFF ON OFF
Actual clamp OFF ON ON
Mistake clamp OFF OFF ON
Unclamp ON OFF OFF
FAQ SV02-380-02-002E 2/3

Procedure to adjust the


Adjusting procedure tool clamp
of tool clamp status
status

Install the proximity switches (distance between dog and switch from 0.4 to 0.6 mm)
Remove the YV700 solenoid head
Screw
Press and keep “unclamp button” YV700
Solenoid head
Install a tool in the spindle them clamp it
Piston come back only with the Belleville spring force
(YV700 not plug).
At the end the drawbar end face and the unclamp
cylinder end face are in contact

Adjust proximity switch base (B56311A) until SQ124


come off (move down). Measure distance A

Adjust proximity switch base until SQ123 come off


(move up). Measure distance B
Move SQ124 to the middle of A distance and fix it
Move SQ123 to the middle of B distance and fix it

Connect YV700 solenoid head, and test if it working


Adjustment done
Distance A and B should be around 3.4mm (design value)
Machine before August 2007 value should be 2.4mm
Installation pitch of SQ123 and SQ124 is between 3.1mm and 2.1mm

Unclamp cylinder
Switch detection width

Proximity switch Installation screw


Installation plate
DOG
Switch installation pitch

Range width to turn


Dog width

Two switches

ON

[ Position where SQ123 come off ] [ Position where SQ124 come off ] DOG
FAQ SV02-380-02-002E 3/3

[Tool clamp detection switches and dog-related figure]

Dog Tool clamp position

Clamp position

Unclamp position

Switches detection width: 3 mm

[Tool clamp switches (dog) stroke-related figure]

Usually Dog don’t stop at this position

Unclamp Mistake Clamp Sky Clamp


clamp with tool clamp

SQ123
(Detection width 3 mm)

SQ124
(Detection width 3 mm)

Dog (width 2.5 mm)


Object machine: Machine after 09/2007