This document lists maintenance tasks needed for various FAHUs (Fan Air Handling Units) and PACUs (Packaged Air Conditioning Units) at different locations. Issues include non-working fans, compressors and contactors, gas leaks, damaged ducts and filters, faulty control panels and displays. The tasks are to be completed for a total cost of Rs. 42,000 for supply and replacement of back filters across 5 units, Rs. 1,500 to replace a faulty genset control panel, Rs. 1,500 for a faulty capacitor bank display, and various other repair and replacement jobs for expansion joints, cable entries, roofs, shafts, insulation, trunking, fittings and more.
This document lists maintenance tasks needed for various FAHUs (Fan Air Handling Units) and PACUs (Packaged Air Conditioning Units) at different locations. Issues include non-working fans, compressors and contactors, gas leaks, damaged ducts and filters, faulty control panels and displays. The tasks are to be completed for a total cost of Rs. 42,000 for supply and replacement of back filters across 5 units, Rs. 1,500 to replace a faulty genset control panel, Rs. 1,500 for a faulty capacitor bank display, and various other repair and replacement jobs for expansion joints, cable entries, roofs, shafts, insulation, trunking, fittings and more.
This document lists maintenance tasks needed for various FAHUs (Fan Air Handling Units) and PACUs (Packaged Air Conditioning Units) at different locations. Issues include non-working fans, compressors and contactors, gas leaks, damaged ducts and filters, faulty control panels and displays. The tasks are to be completed for a total cost of Rs. 42,000 for supply and replacement of back filters across 5 units, Rs. 1,500 to replace a faulty genset control panel, Rs. 1,500 for a faulty capacitor bank display, and various other repair and replacement jobs for expansion joints, cable entries, roofs, shafts, insulation, trunking, fittings and more.
Price ▪FAHU 1 LOCATION- PRINCIPAL CORRIDOOR 1. SUPPLY FAN IS NOT WORKING IN AUTO MODE 2. DAMAGE ON DUCT 3. COMPRESSOR B2 AND CONTACTOR IS NOT WORKING
4. THERE IS ISSUE WITH DISPLAY PANNEL
▪ FAHU 2
LOCATION- GF
1. FILTER DOOR HANDLE DAMAGE
▪FAHU 3
LOCATION- FF
1. SUPPLY FAN AND RETURN FAN IS NOT
WORKING IN AUTO MODE (VFD PROBLEM)
2.CONDENSOR B1 AND B2 IS HAVING GAS
LEAKAGE. 5 Lot 1 42,000 ▪FAHU 4 LOCATION- FF AND GF ADMON AREA 1. SUPPLY FAN IS NOT WORKING AUTO MODE (VFD PROBLEM) 2. FILTER DOOR HANDLE DAMAGE * Supply and replacment of FAHU back filters
▪PACU 1
LOCATION- MAIN RECEPTION
1. SUPPLY FAN AND COMPRESSOR IS NOT
WORKING. ▪PACU 2 LOCATION- INDOOR PLAY AREA 1. SHORT OF GAS NEED TOP UP *Replacment of Split unit compressor - 1 no & repairing of 2 split units leakage Supply and replacment of Faulty Control Panel of 12 Lot 1 1,500 Genset Supply and replacment of Faulty Display of 13 Lot 1 1,500 Capacitor Bank 22 Expansion joint cover required LM 1 1,900 23 Cable entries opening requires sealing Lot 1 1,900 24 All cracks on roofs requires repair Lot 1 1,900 25 All shaft openings to seal Lot 1 900
All ac and electrical cables requires proper foster