[E.2] Energy Management - Plant and Equipment Checklist Issue 1 - October 2019
1 Use more efficient lighting fixtures such as compact fluorescent or LED lights 5.3% Moderate 3.9% 0.0% Not Applicable 0.0%
2 Ensure light fixtures are properly oriented to light the required work area/pathways 2.6% Moderate 2.0% 2.5% Moderate 1.9%
Ensure that light fixtures are zoned or are not on a single wiring circuit to control lighting
3 more efficiently allowing the light fixtures to be switched off when not required, for example 3.9% High 3.9% 3.7% High 3.7%
when day light is available or work is not scheduled in that area
Ensure that light fixtures are clean and maintained properly such that the light output is as
4 close as possible to the manufacturer specifications 1.3% High 1.3% 1.2% High 1.2%
5 Consider renewable energy sources for whole or part of site lighting 6.6% High 6.6% 6.2% High 6.2%
6 Ensure that flickering or damaged lights present on site are replaced 1.3% High 1.3% 1.2% High 1.2%
Ensure that generators are not oversized and run at low load conditions. Calculate the
genrator load factor based on the KWh that the generator would have produced at rated
power for the assessment period and the actual KWh reading from the generator energy
meter for the same assessment period.
7 (Effeciency less than 30% = None,
5.3% High 5.3% 4.9% High 4.9%
Effeciency between 30-40% = Low,
Effeciency between 40-50% =Med,
Effeciency above 50% =High)
8 Ensure that generator air intake path is clear of any obstruction 2.6% High 2.6% 2.5% High 2.5%
9 Monitor the overall electricity consumption from the generators 0.0% Not Applicable 0.0% 14.8% High 14.8%
10 Connect to the grid wherever possible 3.9% High 3.9% 3.7% High 3.7%
Ensure that the dewatering pump flow rate and horsepower are suitable for the required
1 piping length and discharge flow. 6.6% High 6.6% 6.2% High 6.2%
3 Ensure that the fans are off when not required for occupational or health reasons. 3.9% High 3.9% 0.0% Not Applicable 0.0%
Select electrically operated tower cranes with power optimization and control features. A
1 frequency converter regulating all drives and variable speed hoisting winch make cranes 0.0% Not Applicable 0.0% 0.0% Not Applicable 0.0%
more energy efficient than conventional cranes.
Ensure that air compressor and compressed air hoses are leak free in order to avoid longer
2 run times for the compressor. Air compressor motor with high efficiency rating will conserve 13.2% Moderate 9.9% 12.3% Moderate 9.3%
additional energy.
1 Ensure operators are trained in energy saving practices. 18.4% Moderate 13.8% 17.3% Moderate 13.0%
Level 3 3
Submittals
1.Electricity invoices.
2. Single line diagram showing the location of the tie-in point for the utility supplier.
Submittals
Submittals
1. Compressors specifications.
2. Calculations showing the average efficiency of the compressors motors.
3. Photos of the compressors on site.
Submittals