PROJECT : PROPOSED RENOVATION OF INTERIOR SPACE OF SPA

LOCATION : Primark Town Center Atherton, Novaliches, Quezon City, Metro Manila
OWNER : NUAT THAI ATHERTON - FAIRVIEW

TECHNICAL SPECIFICATIONS

 GENERAL CONDITION

 The Drawing and Specifications are complimentary and supplementary to each other.
Anything mentioned in the specifications but not shown in the drawings or vice-versa shall
be of effect as if mentioned in both.

 All drawings are done according to scale. Numerical values are indicated in drawings. But if
there are indicated numerical values drawings shall be measured by the scale, But if there is
a discrepancy, the numerical value indicated are to be followed instead of the scale.

 All works mentioned herein shall be final. Any revisions to be done shall be settled between
the owner and the Engineer in charge of the construction.

 INTERIOR FINISH

 Paint shall either be Boysen or any approved equivalent brands.

 Floor finishes shall be as follows:

 Main area using 60 x 60cm Homogeneous tiles

 Toilets & Countertop Using 30 x 30 ceramic tiles


 Ceiling finishes shall be as follows:

 19mm gypsum boards on metal framing


 Curtain Rods:

 ELECTRICAL WORKS

 All electrical wires shall be of standard type (PHILFLEX or equivalent).


 All electrical conduits shall be flexible type (MOLDIFLEX or equivalent).
 Switches, convenience outlets including plates shall be NATIONAL or equivalent.
 Circuit Brakes shall be GENERAL ELECTRIC or equivalent.

PROJECT : PROPOSED RENOVATION OF INTERIOR SPACE OF SPA


Prepared By:
Arch. Jan Nikolai D. Gongora, rmp
AR-0040782 PTR NO. - 9071303
ISSUED ON: JAN 12, 2018/TAYTAY RIZAL
LOCATION : Primark Town Center Atherton, Novaliches, Quezon City, Metro Manila
OWNER : NUAT THAI ATHERTON - FAIRVIEW

 PLUMBING WORKS

Pipes and Fittings -

Waterlines – ., use PPR PN20

Elbows, tees, unions, valves and fittings - use PPR PN20

Sewer and storm drainage– series 1000 only

Sanitary Vent Pipe, sewer & storm embedded at ground - PVC pipes, series 1000 only

Miscellaneous -

Floor Drains - heavy-duty stainless strainer, with flapper only. Those at shower area, provide
basket strainer.

Clean Out Cover – must be of brass material except for ceiling-mounted clean-out, wherein PVC
shall be used. For septic tank, use countersunk CO. (brass).

Air Chamber (300 mm. long) shall be provided for all waterline outlets; all necessary fittings shall
be provided.

Air Vent – use Studor from Camp Marketing.

 DOORS AND HARDWARE

 All locksets shall be SCHLAGE or approved equal.


 Main Entry Door: Glass Door with fixed glass curtain wall
 All hinges shall be of quality, loose pin type, STANLEY or equivalent

 PAINTS & VARNISHES

1.) Unless specified all brand of paint shall be Boysen or Dutch Boy.

2.) All exposed wood work shall be applied first with wood stain.

 Sanding is an essential part of painting works. Therefore, all cracks joints and nails shall be
glued and concealed first with wood filler.

 Paints shall be applied in three coats.


*Masonry Surfaces Acrylic paint semi-gloss
*Wood & Metal Surfaces Quick Drying Enamel & Varnish
*Ceiling Flat Wall Enamel

Prepared By:
Arch. Jan Nikolai D. Gongora, rmp
AR-0040782 PTR NO. - 9071303
ISSUED ON: JAN 12, 2018/TAYTAY RIZAL