Design Input

Footing: 1

Geometry Data
Footing Depth, d 600 mm
Footing Depth, Df 1.5 m
Footing Length 4.8 m #REF!
Footing Base 2.4 m #REF!
Column dimension along x-dir. 450 mm
Column dimension along y-dir. 450 mm

Loading Data
Ultimate Moment 372.26 kN-m
Axial Load 1746.91 kN
Soil Bearing Capacity 125 kPa
Unit Weight of Soil 15.2 kN/m³

Material Properties
Compressive strength of concrete, Fc' 21 MPa
Yield strength of steel reinf., Fy 275 MPa

Reinforcement Details
Clear Cover Top 75 mm
Main Bar Size 16 mm
Sec. Bar Size 12 mm
10
Remarks: Fail! 25
Footing: 1

Design Data

Footing Depth, d = 600 mm

Footing Depth, Df = 1.5 m

Footing Length = 4.8 m

Footing Base = 2.4 m

Column dimension along x-dir. = 450 mm

Column dimension along y-dir. = 450 mm

Main Bar Size = 16 mm

Secondary Bar Size 12 mm

Clear Concrete Cover = 75 mm

Ultimate Moment = 372.26 kN-m

Service Moment = 132.95 kN-m

Axial Load = 1746.91 kN-m

Service Axial Load 1248 kN

Design Parameters

Computation of β

If Fc' ≤ 28 MPa

use β = 0.85

If Fc' > 28 MPa

use β = 0.85-.05(Fc'-28)/7 = ------

Design β = 0.850

Computation of ρmin

ρmin = 1.4/Fy = 0.005

Computation of ρbal
ρbal = 0.85β(600/(600+Fy)Fc'/Fy = 0.038

Computation of ρmax

ρmax = 0.75ρbal = 0.028


Effective Depth of Footing

d = 525 mm

Effective Soil Bearing Capacity

qe = 111.32 kPa

Check the Dimension of the Footing

𝑞_𝑚𝑎𝑥=−𝑃/𝐴±6𝑀/(𝑏𝑑^2 )

Lallow = 5.25 m

Lactual < Lallowable

4.8 < 5.25 Fail!


Design of Footing
𝑞_𝑚𝑎𝑥=−𝑃/𝐴±6𝑀/(𝑏𝑑^2 )
= -192.76 kPa

𝑞_𝑚𝑖𝑛=−𝑃/𝐴±6𝑀/(𝑏𝑑^2 )
= -111.97 kPa

Investigate the Adequacy of Assumed "d" on Wide-beam Shear

0.45
d 1.65

111.97
z
y
80.79
192.76
3.15

4.8

y = 53.018 kPa
z = 164.988 kPa

Vu = 708.342 kN

Vc = 1/6√(f'c)bd = 962340.896 kN

= 962.341 kN

ØVc = 721.756 > 708.34


Safe!
Check the adequacy of "d" in Punching Shear

4.8

1.5
0.45
0.45

`
2.4

1.5

bo = 3.9 m

Vc = 1/3√(f'c)bod = 3127.61 kN

Vu = ØVc = 2345.71 kN

Apunch = 9.27 m

Vpunch = 1031.94 kN

Vu > Vpunch Safe!

Steel Requirements

Along long direction

0.45

2.175
111.97 z
y
80.79
192.76
2.625

4.8

y = 44.18 kPa

z = 156.15 kPa

Mu = 1024.98 kN-m

Ru = Mu/Φbd² = 1.72 Mpa

0.85f'c 2Ru
ρ= 1 - 1-
fy 0.85f'c

ρ = 0.00660

Design ρ = 0.00660

As = ρbd = 8311 mm²

Bar Selection and Arrangement

Bar Size = 16 mm

Number of Bars = 42

Along Short Direction

Fu = 713.07 kN

Mu = 347.621 kN-m

Ru = Mu/Φbd² = 0.29 Mpa

0.85f'c 2Ru
ρ= 1 - 1-
ρ= 1 - 1-
fy 0.85f'c

ρ = 0.00107

Design ρ = 0.00509

As = ρbd = 14032 mm²

Bar Selection and Arrangement

Bar Size = 16 mm

Number of Bars = 70

β = 2.000

Number of Bars at Center Band = 47


12
Number of Bars at Outer Strip = 12

Development Length

Ld = 0.02Abfy/√f'c = 241.31 mm

or
Ld = 0.06dbfy = 264 mm

Min Ld furnised = 900 mm

Ok!
Design Output

Footing: 1

Geometry Data
Footing Depth 600 mm
Footing Length 4.8 m
Footing Base 2.4 m
Column dimension along x-dir. 450 mm
Column dimension along y-dir. 450 mm

Loading Data
Ultimate Moment 372.26 kN-m
Axial Load 1746.91 kN

Material Properties
Compressive strength of concrete, Fc' 21 MPa
Yield strength of steel reinf., Fy 275 MPa

Reinforcement Details
Clear Cover 75 mm
Main Bar Size 16 mm
Sec. Bar Size 10 mm
At Long Direction
Number of Bars 42 pcs.
At Short Direction
Number of Bars 71 pcs.
Number of Bars at Center Band 47 pcs.
Number of Bars at Each Outer Strip 12 pcs.
Footing: 1

2.4 m with 42 bars