You are on page 1of 1

Amps X 10 Bus23 (Nom. kV=6.6, Plot Ref. kV=6.

6)
.5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K
1K 1K

Cable10
500 SF-P1347/8/9 Ampacity 500

Ampacity 240 Amps


300 709.8 Amps 300
CB203

CB203-PD - P ±

OC1
100 100
R CB203-PD
Schneider Electric (GPA)
±
Sepam 40

50
CT Ratio 200:5
50
R CB203-EF PD
IEC - Extremely Inverse
Pickup = 0.33 (0.1 - 2.4 xCT Sec)
30 Time Dial = 0.5 30
3x = 6.19 s, 5x = 2.06 s, 8x = 0.786 s
Inst = 5 (0.1 - 24 xCT Sec) Cable10
1-3/C 70
10 10
SF-P1347/8/9 - P
9 - 1/C 150 mm²
5 Copper XLPE 5
Cable10 - P
Seconds

Seconds
Tc = 90C
Plotted - 3 x 150 mm² 1 - 3/C 70 mm²
3 Copper XLPE 3

Tc = 90C TF58 0.75 MVA


TF58 Plotted - 1 x 70 mm²
0.75 MVA (Secondary) 5 %Z
1 Delta-Wye Solid Grd 1

.5 .5

BUS-SF-FWG-T1-LV
.3 .3

SF-P1347/8/9
TF58
Inrush
9-1/C 150
.1 .1
Multiplier = 12 xFLA
(12000.35 Amps @ 0.433 kV)
Duration = 5 Cycles
.05 .05
SW2
.03 Bolted Fault Current, Ibf .03
14.942kA @ 0.415kV
CB203-PD - 3P BUS-SF-FWG-LV
Bus Arcing Current, Ia 18.26kA @ 6.6kV
9.663kA @ 0.415kV
.01 .01
.5 1 3 5 10 30 50 100 300 500 1K 3K 5K 10K