You are on page 1of 1

5.

1001

6.0011 6.0000 6.0000 6.0001 6.0250 6.0263 6.0000 6.0000 6.0677


GENERAL NOTES
CONDUCTOR:
3.9790 11.6000
· SHALL NOT BE SMALLER THAN A 26AWG
3.8209
· SINGLE CONDUCTOR NO SMALLER THAN 18AWG
3.8000

· SOLID OR STRANDED CONDUCTOR. BARE COPPER FOR LOW


A DCR
4.0000 5.3000

RECEIVING DISPATCH
INSULATION:

AREA
E FIRE ALARM SPECIFICATIONS
Mains supply : 230V a.± 10% 50/60Hz.Max current 680mA
· POLYPROPYLENE INSULATION FPLR

STORAGE
5.0000 Internal power supply : 27V d.c Nominal

AREA
Total output current limited to : 3A @ 230 V a.c

ROOM
Power rating : Imax. a = 250mA (1 loop) 270mA (2 loop); Imin. = 70mA
· FLUROPOLYMER INSULATION TEFON FPLP Maximum internal resistance : Ri max. - 1.1Ω
7.5000 Supply and battery charger monitored for failure : Yes

· CONDUCTORS MUST BE TWISTED. Batteries monitored for disconnection and failure


Batteries protected against deep discharge
: Yes
: Yes
A S S S S S Max. battery size and type : 7.0 Ahr VRLA

SHIELD: Specified batteries for LPCB approved systems : 2 x Yuasa NP7-12

LOCKER &
CHARGING
5.0000

EE ROOM
FACP Quiescent current drain :< 80mA (1 loop unloaded); <100mA (2 loops unloaded)

BAY
Earth fault monitoring : Yes (any conductor)
· DEPENDENT ON THE SYSTEM REQUIREMENTS AND

S
2.5420

SHE

UP
Temperature compensated charging : Yes
S S S S S S S S S

R
ENVIRONMENTAL CONDITIONS

HE
LEGEND
S 7.5000
S S S S S S S S

PQ

W1
S
A · UNSHIELDED OR SHIELDED

S S S S S S S S · SHIELD SHALL USED TO PROTECT AGAINST INTERFERENCE

NO
S 7.4821
CREATED FROM OTHER CABLES OR OUTSIDE ELECTRONIC/ FACP

W2
5.4000 ELECTRICAL OR MECHANICAL DEVICES.
S S S S S S S S S A

LM
6.0000 S · SHIELD SHALL 100% ALUMINUM FOIL WRAP
A S S S S S S S S
JK
JACKET:

W2
17.5000
6.0000 A
S S S S S S S S S · PVC FOR NON-PLENUM FPLR
HI

52.4155
S
6.0000
B · FLEXIBLE FIRE RETARDANT PVC FOR FPLP
S S S S S S S S
FG

· JACKET COLOR: SHALL RED, BUT CAN BE ANY COLOR.


6.0000 UP

S S S S S S S S S
DE

ELECTRICAL CHARACTERISTICS:
17.5000
6.0000 A · USE SOLID CORE NO. 14 AWG SIZE COPPER FOR SMOKE
S S S S S S S S S
BC

DETECTORS, HEAT DETECTOR AND FOR ALL FIRE ALARM


FIXTURES. ALL FIXTURES MUST ADDRESSABLE.
6.0000 A
A

A A
· CAPACITANCE: MUST BE LOWER THAN 20PF/FT
2.4000

6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000
A-3 GROUND FLOOR PLAN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 SCALE 1:100M

PERMIT PLAN
JANUARY 2022

FIRE DETECTION ALARM SYSTEM LAYOUT


PROPOSED DESIGN OF A2Z LOGISTIC INC PROFESSIONAL ELECTRONICS ENGINEER
GENERAL DETAILS AND DIAGRAM
FIRE DETECTION ALARM SYSTEM P.T.R. NO.:
DATE ISSUED:
TIN NO.:
REG. NO.
AUX-1
PLACE ISSUED: