Design Beam Reaction for CIDB Hostel

Input

Beam
Width= 0.25 m
Depth= 0.45 m
Length= 6 m
Applied brickload= 2.6 kN/m2 ==> Height= 0 m

Slab
Tributary width= 3.5 m
Thickness= 0.15 m
SDL= 1.2 kN/m2 (50mm thk. screeding)
LL= 3 kN/m2

Roof
Tributary width= 2.7 m

(a) Dead Load:


Ceiling type= 3.2 mm (3.2mm ceiling board)
Ceiling dead load= 0.25 kN/m2
M&E= 0.25 kN/m2
Roofing material= 0.15 kN/m2 (metal roofing + purlins)
Total Roof DL= 0.65 kN/m2

(b) Live Load:


Roof LL= 1 kN/m2 (for maintenance purposes)

Loading
(a) Dead Load:
Beam s/w= 2.7 kN/m
Slab s/w= 12.6 kN/m
SDL= 4.2 kN/m
Brickload= 0 kN/m
Roof DL= 1.755 kN/m
Total DL= 21.255 kN/m

(b) Imposed Load:


Slab LL= 10.5 kN/m
Roof LL= 2.7 kN/m
Total LL= 13.2 kN/m

Design Loading:
Beam UDL= 50.9 kN/m (1.4DL+1.6LL)
Moment, M= 228.9 kNm
Reaction, V= 152.6 kN
(3.2mm ceiling board or 18.75 Gypsum Ceiling Board)

(Roof tiles with timber truss framing & battens=0.55kN/m2) or (metal roofing+purlins=0.15kN/m2)
3.2
18.75

0.15
0.55