Professional Documents
Culture Documents
Page 1 of 2
Design of Boundary wall with Strip foundation‐pillar location
Sno Description = Value Units
Factored pressure from the foundation = 98.89 Kn/m
Max bending moment at the face of beam = 49.44 Kn‐m/m
Depth required as per BM = 117 mm
Depth provided in mm is = 300 ok
Effective depth = 250 mm
2 2
MU / ( b X d ) = 0.79 N / MM
Shear at above point = 49 KN/m
2
PU / ( b X d ) = 0.20 N / MM
2
Allowable shear stress = 0.28 N / MM
Shear stress of the footing is OK
% of Steel as per Table ‐ 3 of SP : 16 = 0.189
% of Steel as per Table ‐ 19 of IS: 456 = 0.120
Required Area of Steel for Maximum of above = 4.72 Sq.CM
Min. Requirement as 0.12% of Gross Area = 3.60 Sq.CM
Max. of above = 4.72 Sq.CM
Reinforcement Dia Proposed = 10 MM
Spacing Proposed as per above & to Table‐96 = 100 MM
Provided Area of Steel as per Table‐96 = 7.86 Sq.CM
Provide 10 Dia @ 100 C/C in both ways and ok
E) Checking of the Brickwork tensile stress
H/L ratio =1
Since H/L ratio exceeds 0.3 and panel is free at top and supported on
other 3 edges, maximum bending will be in the horizontal direction,
and by interpolation from Table 12 of the Code it will be:
Max moment = PL/12
0.083 x P x H X L X L =
= 555 n‐m
Section Modulus ‐ bd^2/6‐2.5x 0.23^2/6 = 0.022 m3
Tensile stress‐ M/z = 25182 n/m2
= 0.025 N/mm2
Allowable tensile stress for 1:6 mortar = 0.05 N/mm2
Hence the allowable stress of brickwork is ok
Page 2 of 2