You are on page 1of 1

DAF RECYCLE PUMP

PROJECT : MUNDRA BATHINDA PIPELINE PROJECT


JOB NO.: 1206 CLIENT : HMPL ITEM NO.: 082-P-04 A/B
SERVICE TO RECYCLE DAF EFFLUENT
TYPE CENTRIFUGAL, HORIZONTAL (NON CLOG)
PROPERTIES OF LIQUID
LIQUID HANDLED EFFLUENT EX DAF TANK
o
PUMPING TEMP. ( C) AMBIENT
VISCOSITY AT PUMPING TEMP. (cP) ~1
2
V. PR. AT PUMPING TEMPERATURE (kg/cm .abs) 0.074 R1
3
LIQUID DENSITY (kg/m ) 1000
PRESENCE OF CORROSIVE/TOXIC COMPONENTS NO
SOLIDS IN SUSPENSION (YES/NO) YES ( TRACES )
SIZE OF SOLID PARTICLES (mm) (MAX) 3-5
OPERATING CONDITIONS
3
NORMAL (m /hr) 13
3
FLOW RATE MAX (m /hr) 13
3
MIN (m /hr) 4.5
2
SUCTION PRESSURE (kg/cm abs) ATM
2
DISCHARGE PRESSURE (kg/cm abs) 7.00
2
DIFFERENTIAL PRESSURE (kg/cm .g) 6.00 R1

DIFFERENTIAL HEAD (m) 60


R1
NPSH AVAILABLE (m) MIN. 11.13
NO. OF PUMPS 2 (1W+1S)
CAPACITY CONTROL FOR VOLUMETRIC PUMPS
CONTINUOUS/DISCONTINUOUS/ N.A.
MANUAL/AUTOMATIC
TYPE N.A.
RANGE (%) N.A.
PRECISION AT MIN. RATE (%) N.A.
MECHANICAL DATA
2 R1
DESIGN PRESSURE (kg/cm (abs)) 8.6
o
DESIGN TEMPERATURE ( C) 65
CASING CS
MATERIAL CODE
IMPELLER CS
SEAL TYPE (MECHANICAL/PACKING) PACKING
LINE RATING IN/OUT 150 # / 150#
DRIVER ELECTRICAL MOTOR

NOTES :
1. THE PUMP MOTOR SHALL BE SIZED FOR OPEN DISCHARGE CONDITIONS.

R1 04.01.2010 REVISED AS PER COMMENTS PR MJ JNP


R0 16.7.2009 ISSUED FOR APPROVAL MJ JNP JNP
NO. DATE REVISION PREPARED CHECKED APPROVED
HINDUSTAN DORR OLIVER PROCESS DATA SHEET REV.
DAF RECYCLE PUMP
LIMITED MUMBAI 1206-DS-015 R1

You might also like