Professional Documents
Culture Documents
90M
VIA PRINCIPAL N° 03 - TRAMO N° 03 - LADO DERECHO - PROG. 0+360 - 0+415
Date :
Settings
(input for current task)
Materials and standards
Concrete structures : ACI 318-11
Wall analysis
Active earth pressure calculation : Mazindrani (Rankine)
Passive earth pressure calculation : Mazindrani (Rankine)
Earthquake analysis : Mononobe-Okabe
Shape of earth wedge : Consider always vertical
Base key : The base key is considered as inclined footing bottom
Allowable eccentricity : 0.167
Verification methodology : Safety factors (ASD)
Safety factors
Permanent design situation
Safety factor for overturning : SFo = 2.00 [–]
Safety factor for sliding resistance : SFs = 2.00 [–]
Safety factor for bearing capacity : SFb = 1.00 [–]
Material of structure
Unit weight = 23.00 kN/m 3
Analysis of concrete structures carried out according to the standard ACI 318-11.
1
MURO DE CONTENCION H=5.90M
VIA PRINCIPAL N° 03 - TRAMO N° 03 - LADO DERECHO - PROG. 0+360 - 0+415
The origin [0,0] is located at the most upper right point of the wall.
Wall section area = 4.35 m2.
Name : Geometry Stage - analysis : 1 - 0
0.25
5.40 22.00:1
5.90
6.50
1.05 2.65
0.50
1.10
4.20 0.40
Foundation
Type of foundation : input parameters of contact base-soil
Parameters
2
MURO DE CONTENCION H=5.90M
VIA PRINCIPAL N° 03 - TRAMO N° 03 - LADO DERECHO - PROG. 0+360 - 0+415
3
MURO DE CONTENCION H=5.90M
VIA PRINCIPAL N° 03 - TRAMO N° 03 - LADO DERECHO - PROG. 0+360 - 0+415
Name : Verification Stage - analysis : 1 - 1
15.58
244.13
5.90
6.50
13.61
100.06
146.27
2.57
+x
4.20
+z
Eccentricity verification
Max. eccentricity of normal force e = 0.085
Maximum allowable eccentricity ealw = 0.167
Eccentricity of the normal force is SATISFACTORY
4
MURO DE CONTENCION H=5.90M
VIA PRINCIPAL N° 03 - TRAMO N° 03 - LADO DERECHO - PROG. 0+360 - 0+415
5.90
6.50
4.20
4.20
44.10
136.29
Dimensioning No. 1
Wall stem check - front reinf.
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -2.40 46.28 0.30 1.000
Pressure at rest 143.55 -1.80 0.00 0.50 1.000
S/C 18.33 -2.70 0.00 0.50 1.000
Wall stem check - front reinf.
Front reinforcement is not required.
Wall stem check - back reinf.
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -2.40 46.28 0.30 1.000
Pressure at rest 143.55 -1.80 0.00 0.50 1.000
S/C 18.33 -2.70 0.00 0.50 1.000
Wall stem check - back reinf.
Wall check at the construction joint 5.40 m from the wall crest
Reinforcement and dimensions of the cross-section
6 prof. No. 5, cover 75.0 mm
6 prof. No. 5, cover 75.0 mm
Inputted reinforcement area = 2375.2 mm 2
Required reinforcement area = 2125.5 mm 2
Cross-section width = 1.00 m
Cross-section height = 0.50 m
5
MURO DE CONTENCION H=5.90M
VIA PRINCIPAL N° 03 - TRAMO N° 03 - LADO DERECHO - PROG. 0+360 - 0+415
Wall jump check
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -1.45 100.06 1.86 1.000
FF resistance -2.57 -0.17 0.00 0.00 1.000
Weight - earth wedge 0.00 -3.20 244.13 2.87 1.000
Active pressure 146.27 -1.57 0.00 4.20 1.000
S/C 13.61 -2.64 0.00 4.20 1.000
S/C 0.00 -5.90 15.58 2.87 1.000
Wall jump check
Reinforcement and dimensions of the cross-section
7 prof. No. 4, cover 75.0 mm
Inputted reinforcement area = 886.7 mm 2
Required reinforcement area = 759.3 mm 2
Cross-section width = 1.00 m
Cross-section height = 0.50 m
Reinforcement ratio = 0.21 % > 0.18 % = min
Position of neutral axis c = 0.02 m < 0.18 m = cmax
Ultimate shear force Vn = 236.61 kN > 118.92 kN = Vu
Ultimate moment Mn = 134.18 kNm > 87.18 kNm = Mu
Cross-section is SATISFACTORY.
Wall heel check
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -0.25 30.47 2.87 1.000
Weight - earth wedge 0.00 -3.20 244.13 2.87 1.000
Active pressure 146.27 -1.57 0.00 4.20 1.000
S/C 13.61 -2.64 0.00 4.20 1.000
Contact stress 0.00 0.00 -194.03 2.69 1.000
Gravity surch. 1 0.00 -5.90 15.58 2.87 1.000
Wall heel check
Reinforcement and dimensions of the cross-section
8 prof. No. 5, cover 75.0 mm
Inputted reinforcement area = 1583.5 mm 2
Required reinforcement area = 1471.8 mm 2
Cross-section width = 1.00 m
Cross-section height = 0.50 m
Reinforcement ratio = 0.38 % > 0.33 % = min
Position of neutral axis c = 0.04 m < 0.18 m = cmax
6
MURO DE CONTENCION H=5.90M
VIA PRINCIPAL N° 03 - TRAMO N° 03 - LADO DERECHO - PROG. 0+360 - 0+415
Name : Dimensioning Stage - analysis : 1 - 1
15.58
244.13
6.50
13.61
+x
7 prof. No. 4, cover. 75.0mm
4.20
+z
194.03
Name : Dimensioning Stage - analysis : 1 - 1
15.58
244.13
6.50
13.61
+x
7 prof. No. 4, cover. 75.0mm
4.20
+z
194.03
7
MURO DE CONTENCION H=5.90M
VIA PRINCIPAL N° 03 - TRAMO N° 03 - LADO DERECHO - PROG. 0+360 - 0+415
15.58
244.13
+x
7 prof. No. 4, cover. 75.0mm
4.20
+z
194.03
Name : Dimensioning Stage - analysis : 1 - 1
15.58
244.13
+x
7 prof. No. 4, cover. 75.0mm
4.20
+z
194.03