You are on page 1of 2

FINAL TEST REPORT

TEST REPORT NO.: BEL/210810398 of 2021-22 Date: 28/02/2022


NAME OF CUSTOMER: xyz

NAME OF PROJECT: ABC

NAME OF AGENCY: ~
SAMPLE REF NO: WR/RJT/Civil/2021/0037 -Dated: 28/07/2021
DATE: 28-02-2022
SOURCE/BATCH: ~ ID MARK:
SAMPLE RECI DATE: 20-01-2022 TEST DATE: 31-01-22 to 28-02-22
SAMPLE DETAILS: ~ CONDITION: Sealed / Unsealed
SAMPLE TYPE: CEMENT (Physical) LAB NO.: 293
LIMIT AS PER
Test Name Reporting Value
IS:269-2015 (For OPC)
Lab No: 293 ~
Identification Mark ~ ~

Specific surface area(M2/Kg) 322.96 225 (min)


Standard Consistency ( % ) 29.75 ~
Initial Setting Time (Minutes) 105 30(min.)
Final Setting Time (Minutes) 175 600(max.)
Soundness by Le-Chatelier (mm) 1 10(Max.)
Density of Cement (g/cc) 2.96 ~

Compressive Strength (N/mm2) ~


a. @ 72 + 1 hours 41.75 27(Min.)
b. @ 168 + 2 hours 51.97 37(min.)
c. @ 672 + 4 hours 67.58 53(min.)
NOTE: All Test are done as per relevant IS 4031 -1988

( Bhavesh Malviya )
FOR BhoomiQC Engineering Laboratory
NOTE:
1.) This report refers only to the specimen(s) submitted for the test.
2.) This report shall not be reproduced except in full, without the written approval from this laboratory.
3.) The Specimens were collected by the customer and supplied to the laboratory.