Professional Documents
Culture Documents
Precast Reinforced Concrete Pile Drawing No: PLIB/1 & PLIB/2 Taking-Off List Plant and Equipment
Precast Reinforced Concrete Pile Drawing No: PLIB/1 & PLIB/2 Taking-Off List Plant and Equipment
Taking-off list
Plant and Equipment
1 Provision - sum sum H110
2 Moving and handling -sum sum H120
ext pile 6m 2
1
4 8 (P1 at CL 48.20
20
initial 9m
toe level 17.30 H261.3
Supply extension piles of 3m
Commencing Level 1 = 45.00 length and coated with 2 layers of
Ddt toe level = 17.30 2 bituminous oil
27.70 2
1 4 (P1 at CL 45.00
Commencing Level 2 = 48.20
Ddt toe level = 17.30
30.90
Squared by: Abstracted by: Checked by: Page 2
DIMENSION PAPER
UNIVERSITI TUNKU ABDUL RAHMAN
PRACTICAL GROUP:
JOB TITLE : CLASS H PILING WORKS TAKER OFF : IBTISAM AZWANI
ELEMENT: PRECAST REINFORCED CONCRETE PILE DATE: Jun-19
cont'd
Depth diven
CL1= 45.00 H266
Cut-off piles
Commencing level = 45.00 2
Ddt toe level = 17.30 2 4 (P1 at CL 45.00
Ddt pile cap depth = 0.60
Add kicker = 0.075 2
1 2 (P1 at CL 48.20
27.18 6
CL2= 48.20
H267
Commencing level = 48.20 Preparing heads
Ddt toe level = 17.30 2
Ddt pile cap depth = 0.60 2 4 (P1 at CL 45.00
Add kicker = 0.075
2
30.38 1 2
6 (P1 at CL 48.20
(Quantity same as cut-off pile)
H262
2 Depth driven PILE TEST
2 H510
27.18 108.72 (P1 at CL 45.00 1 1 Initial static load test on 250mm x
250mm precast reinforced
concrete pile up to two times
2 working load of 960kN
1 30.38 60.76 (P1 at CL 48.20
169.48
Jointing