 DISTANCE BETWEEN TWO FIRE ESCAPE STAIRCASES SHOULD NOT BE > 30 MT. S

0 < x ≥ 30 0 < x ≥ 30 0 < x ≥ 30 0 < x ≥ 30


`

STAIRCASE FLOOR PLATE

 DISTANCE FROM DEAD END TO STAIRCASE BLOCK SHOULD NOT BE > 15 MT. S.

D
0 < x ≥ 30 0 < x ≥ 15 E

A STAIRCASE

D
FLOOR PLATE
E

 NO ROOMS SHOULD BE WITHOUT VENTILATION

OFFICE

PASSAGE

CORE

1
ARCHITECTURAL DESIGN V
SUMMARY FOR 19/06/2020

 LIFTS SHOULD NOT BE PLACED AROUND STAIRCASE BLOCK

LIFT

FLOOR PLATE

STAIRCASE

 FIRE ESCAPE BLOCKS SHOULD BE PLACES SUCH THAT AT LEAST ONE WALL IS ON THE
EXTERIOR OF THE STRUCTURE.

FLOOR PLATE

FIRE
STAIRCASE
BLOCK

 WIDTH OF ESCALATOR/ INTERNAL STAIRCASE SHOULD NOT BE < 1 MT.

x≥1

FLOOR PLATE

STAIRCASE
BLOCK/
ESCALATOR 2
ARCHITECTURAL DESIGN V
SUMMARY FOR 19/06/2020

 TOILET AND ITS SHAFT SHOULD BE ON THE EXTERNAL WALL

SHAFT

FLOOR PLATE

TOILET

 AHU SERVICING SHOULD BE ON THE EXTERNAL WALL

FLOOR PLATE

AIR
HANDLING

 LIFT SHAFT SHOULD BE 1.8 MT. S *2.0 MT. S MINIMUM.

x ≥ 2.0

FLOOR PLATE

LIFT
y ≥ 1.8

z ≥ 0.25
SHAFT

3
ARCHITECTURAL DESIGN V
SUMMARY FOR 19/06/2020

 SERVICE LIFT IS MANDATORY AND SHOULD BE 2 MT. S * 2.5 MT. S MINIMUM.

REQUIREMENTS THUS CONSIDERED.

DESCRIPTION DIMENSIONS MINIMUM APPROXIMATE

PERSON 8 SQ. MTS

AIR HANDLING UNIT ≥ 50

ESCALATOR 1.5 M WIDTH

FIRE STAIRCASE 4.1* 6

RECREATIONAL ZONE 25%

TRANSFORMER ROOM ≥ 32

GENERATOR ROOM ≥ 32

TOILET 60-100SQ MTS

STAFF TOILET 60-100SQ MTS

FOOD COURT 500-1000

ENTRANCE LOBBY 25 SQ MTS

OFFICE SPACE 25-2000 SQ. MTS

FIRST AID FACILITY 50 SQ. MTS

TREE SHADE 100 SQ. MTS

SEMINAR HALL/ CONVENTION CENTER 200-350 SQ. MTS

FLOOR TO FLOOR HEIGHT 4 MTS MAXIMUM

ORGANIC WASTE COMPOST MACHINE

SEWAGE TREATMENT

RAIN WATER HARVESTING

WASTE WATER MANAGEMENT

SOLAR PANELS

ELEVATOR