You are on page 1of 6

Version 7.2.

PVsyst - Simulation report


Grid-Connected System

Project: Percobaan Tutorial Youtube


Variant: Simulasi Pertama
No 3D scene defined, no shadings
System power: 9.00 kWp
Geneva/Cointrin - Switzerland

Author
Project: Percobaan Tutorial Youtube
Variant: Simulasi Pertama

PVsyst V7.2.3
VC0, Simulation date:
25/05/22 15:34
with v7.2.3

Project summary
Geographical Site Situation Project settings
Geneva/Cointrin Latitude 46.25 °N Albedo 0.20
Switzerland Longitude 6.13 °E
Altitude 420 m
Time zone UTC+1

Meteo data
Geneva
Meteonorm 8.0 (1996-2015) - Synthetic

System summary
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Unlimited load (grid)
Tilt/Azimuth 25 / 20 °

System information
PV Array Inverters
Nb. of modules 30 units Nb. of units 1 Unit
Pnom total 9.00 kWp Pnom total 7.50 kWac
Pnom ratio 1.200

Results summary
Produced Energy 11.49 MWh/year Specific production 1277 kWh/kWp/year Perf. Ratio PR 87.18 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 4
Loss diagram 5
Special graphs 6

25/05/22 PVsyst Licensed to Page 2/6


Project: Percobaan Tutorial Youtube
Variant: Simulasi Pertama

PVsyst V7.2.3
VC0, Simulation date:
25/05/22 15:34
with v7.2.3

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 25 / 20 ° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model Mono 300 Wp 60 cells Model 7.5 kWac inverter
(Original PVsyst database) (Custom parameters definition)
Unit Nom. Power 300 Wp Unit Nom. Power 7.50 kWac
Number of PV modules 30 units Number of inverters 2 * MPPT 50% 1 units
Nominal (STC) 9.00 kWp Total power 7.5 kWac
Modules 2 Strings x 15 In series Operating voltage 150-750 V
At operating cond. (50°C) Max. power (=>25°C) 8.00 kWac
Pmpp 8.10 kWp Pnom ratio (DC:AC) 1.20
U mpp 427 V
I mpp 19 A

Total PV power Total inverter power


Nominal (STC) 9 kWp Total power 7.5 kWac
Total 30 modules Nb. of inverters 1 Unit
Module area 48.8 m² Pnom ratio 1.20
Cell area 42.7 m²

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 378 mΩ Loss Fraction -0.8 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses Strings Mismatch loss


Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel AR coating, n(glass)=1.526, n(AR)=1.290

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000

25/05/22 PVsyst Licensed to Page 3/6


Project: Percobaan Tutorial Youtube
Variant: Simulasi Pertama

PVsyst V7.2.3
VC0, Simulation date:
25/05/22 15:34
with v7.2.3

Main results
System Production
Produced Energy 11.49 MWh/year Specific production 1277 kWh/kWp/year
Performance Ratio PR 87.18 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² MWh MWh ratio
January 33.4 20.36 1.85 50.8 49.5 0.440 0.430 0.942
February 56.1 31.33 2.59 76.6 74.7 0.661 0.647 0.938
March 105.7 44.56 6.67 131.4 128.5 1.087 1.066 0.901
April 138.8 63.42 10.57 154.0 150.1 1.247 1.224 0.883
May 168.3 73.80 14.58 171.7 167.5 1.357 1.331 0.861
June 187.7 85.93 19.11 184.5 179.7 1.434 1.407 0.847
July 187.2 74.13 21.34 188.0 183.2 1.436 1.408 0.832
August 160.5 62.96 20.35 174.7 170.5 1.344 1.318 0.838
September 119.0 55.25 15.68 141.3 137.9 1.119 1.098 0.863
October 72.0 39.11 11.43 92.8 90.4 0.760 0.745 0.892
November 38.5 21.86 5.96 56.8 55.2 0.479 0.468 0.915
December 26.7 15.70 2.73 41.7 40.6 0.358 0.348 0.928
Year 1293.9 588.41 11.12 1464.3 1427.9 11.723 11.489 0.872

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

25/05/22 PVsyst Licensed to Page 4/6


Project: Percobaan Tutorial Youtube
Variant: Simulasi Pertama

PVsyst V7.2.3
VC0, Simulation date:
25/05/22 15:34
with v7.2.3

Loss diagram
1294 kWh/m² Global horizontal irradiation
+13.2% Global incident in coll. plane

-2.48% IAM factor on global

1428 kWh/m² * 49 m² coll. Effective irradiation on collectors

efficiency at STC = 18.45% PV conversion

12.86 MWh Array nominal energy (at STC effic.)


-0.97% PV loss due to irradiance level

-5.77% PV loss due to temperature

+0.75% Module quality loss

-2.10% Mismatch loss, modules and strings

-0.95% Ohmic wiring loss


11.72 MWh Array virtual energy at MPP
-1.98% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
-0.01% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
11.49 MWh Available Energy at Inverter Output
11.49 MWh Energy injected into grid