Professional Documents
Culture Documents
EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.
LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.
SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
A. General:
Damage was avoided during shipment, to all instruments and valves, 32-SAMSS-021,
A1
including auxiliary systems. Para. 25.1.5
All exposed finished and machined surfaces, including bolts, are coated 32-SAMSS-021,
A2
with a rust-inhibiting compound. Para. 25.1.6
Bearings and seal assemblies are fully protected against the entry of 32-SAMSS-021,
A3
moisture and dirt. Para. 25.1.7
Flanged connections and all other machined surfaces are protected by a 32-SAMSS-021,
A4
coating, such as MIL-C-16173 Grade IV. Para. 25.1.8
Flanges are fitted with a steel or wood cover, 3 mm thick and neoprene 32-SAMSS-021,
A5
gaskets. Para. 25.1.8
32-SAMSS-021,
A6 Threaded connections are protected with threaded plugs.
Para. 25.1.12
B. Improper practices or careless handling are likely to result in pipe damage of the following types:
Dents or ovalness of the pipe due to improper supports, or too widely 01-SAMSS-024,
B1
spaced supports and excessive stacking height. Para. 4.3
End damage due to use of improper end hooks for lifting or due to
improper nesting or denesting techniques, or due to longitudinal shifting of 01-SAMSS-024,
B2
the pipe and striking the end of the pipe, which would cause cutting of the Para. 4.3
bevel.
Fatigue cracks due to excessive static and cyclic loads as a result of 01-SAMSS-024,
B3
vertical vibrations during transportation. Para. 4.3
Abrasion or peening due to rubbing or striking of the pipewall against 01-SAMSS-024,
B4
other objects. Para. 4.3
REMARKS:
REFERENCE DOCUMENTS:
1. 32-SAMSS-021, Manufacture of Industrial Boilers, (28 January, 2003)
2. 01-SAMSS-024, Pipe Handling and Nesting, (29 October, 2003)
Page 1 of 5
Quality Record Approved:
Name, Organization,
Name, Sign and Date:
Initials and Date:
Page 2 of 5
SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - June 2008) Rev 3 30-Jun-08
EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.
LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.
SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
A General:
Damage was avoided during shipment, to all instruments and valves, 32-SAMSS-021,
A1
including auxiliary systems. Para. 25.1.5
All exposed finished and machined surfaces, including bolts, are coated 32-SAMSS-021,
A2
with a rust-inhibiting compound. Para. 25.1.6
Bearings and seal assemblies are fully protected against the entry of 32-SAMSS-021,
A3
moisture and dirt. Para. 25.1.7
Flanged connections and all other machined surfaces are protected by a 32-SAMSS-021,
A4
coating, such as MIL-C-16173 Grade IV. Para. 25.1.8
Flanges are fitted with a steel or wood cover, 3 mm thick and neoprene 32-SAMSS-021,
A5
gaskets. Para. 25.1.8
32-SAMSS-021,
A6 Threaded connections are protected with threaded plugs.
Para. 25.1.12
No Dents or out-of-round pipe was found, due to improper support, or too 01-SAMSS-024,
A7
widely spaced supports and excessive stacking height. Para. 4.3
No end damage exists due to use of improper end hooks for lifting or due
to improper nesting or denesting techniques, or due to longitudinal shifting 01-SAMSS-024,
A8
of the pipe and striking the end of the pipe, which would cause cutting of Para. 4.3
the manufacturer's bevel.
No Fatigue cracks exist due to excessive static and cyclic loads as a 01-SAMSS-024,
A9
result of vertical vibrations during transportation. Para. 4.3
No Abrasion or peening exists due to rubbing or striking of the pipe wall 01-SAMSS-024,
A10
against other objects. Para. 4.3
B Packing:
02-SAMSS-005,
C1 All fittings must be protected from mechanical damage.
Para. 10.5
Welding ends must be protected with suitable wood, plastic, or metal 02-SAMSS-005,
C2
covers. Para. 10.5
Page 3 of 5
Fittings must be packaged in steel-banded wooden crates or secured to 02-SAMSS-005,
C3
skids. Para. 10.5
Page 4 of 5
SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - June 2008) Rev 3 30-Jun-08
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
REMARKS:
ATTACHMENTS:
REFERENCE DOCUMENTS:
1. 32-SAMSS-021, Manufacture of Industrial Boilers, (24 January 2004)
2. 01-SAMSS-024, Pipe Handling and Nesting, (10 December 2006)
3. 02-SAMSS-005, Butt Welding Pipe Fittings, (3 July 2007)
Page 5 of 5