You are on page 1of 10

Mounting systems for solar technology

K2 SYSTEMS GMBH PROJECT: Magura

AUTHOR:

CALCULATION BASIS DATE: 9/29/2022


Mounting systems for solar technology

PROJECT DATA

GENERAL INFORMATION
Name Magura
Mounting System D-Dome 6.10 Xpress

LOCATION
Address Strada Măgura Vulturului 58,
București
Ground level 78.60 m
Roof type Flat roof
Fastening method with Ballast
Roof covering Flat
Building height 10.00 m
Parapet wall height 0.20 m
Roof pitch 0°
min. roof edge distance 0.60 m
Material Membrane
Friction coefficient 0.50
To ensure proper ballast calculation, coefficient of friction to be verified by Designer or Installer. Refer to
the technical information section of website for values on common roof types.

LOADS
Design method SR EN
Failure consequence class CC2 Design working life 25 years

Wind load zone 0.4 kN/m²


Terrain category I: I - Lakes, low
vegetation
velocity pressure qp,25= 1.020 kN/m²

Snow load zone 1.5


Snow load on ground sk = 1.500 kN/m²
level

MODULES
Manufacturer Canadian Solar Inc. Quantity 70
Name CS3L-380MS HiKu Total output power 26.600 kWp
(1500V)
Dimensions LxWxH 1765 x 1048 x 35.00 mm
Weight 20.5 kg
Output power 380 W

9/29/2022 K2 Base 3.1.47.0 2 | 9


Mounting systems for solar technology

ASSEMBLY PLAN

8.49 m

2 19.66 m
23.11 m

1
m
63

m
6.

3.99
Dimensions in [m]

9/29/2022 K2 Base 3.1.47.0 3 | 9


Mounting systems for solar technology
LEGEND

Distance to neighboring module array [m]

Distance to roof edge [m]

Module count

Length/width of module array [m]

Row distance [m]

0.64 0.64

2.28
-0.06 0.06

1
4 7.21

-0.06 0.06
6

13.65
-0.05 -0.05

0.64 0.64

2.28
0.06 0.74

2
4 7.21

0.06 0.74
3

6.81
0.64 0.64

9/29/2022 K2 Base 3.1.47.0 4 | 9


Mounting systems for solar technology

BALLAST PLAN

1
35.0
26.026.0 18.5 18.5 18.5 18.5

31.5
23.023.0 23.5 23.5 23.5 23.5

28.0
23.023.0 28.0 28.0 28.0 28.0

31.5
39.5 23.5 23.5 23.5
26.026.0
35.0
18.5 18.5 18.5
26.026.0

2
26.026.0
20.520.5 34.5

26.026.0
23.023.0 22.022.0

26.026.0
26.026.0 26.026.0

26.026.0
23.023.0 22.022.0

26.026.0
34.5
20.520.5

9/29/2022 K2 Base 3.1.47.0 5 | 9


Mounting systems for solar technology

RESULTS

BALLAST CAPACITY
Speed Porter 40.0 kg
Porter 108.0 kg
module clamp MiniClamp MC Set 30-50
end clamp MiniClamp EC Set 30-50

VERIFICATION SYSTEM UTILIZATION

Verification system utilization [%] pressure 72.38


suction 65.09
Loads on modules (ultimate state) [Pa] pressure 2806
suction -1418
Loads on modules (serviceability) [Pa] pressure 1881
suction -910

SPECIFIC LOADS

Index number of --- --- Ballast required Dead weight [kg] Dead Load Dead Load Dead load
(module block) supports [kg] [kN/m²] [kN/m²] [kN/m²]
(module block) (module block) (module block) (module block) (roof surface
area)

module array 1 23 --- --- 854.5 1875.7 0.20 --- ---


module array 2 12 --- --- 695.0 1227.8 0.25 --- ---
all Blocks 35 0 --- 1549.5 3103.5 --- --- ---

NOTES
- The proof of position safety and load capacity of the system are carried out by checking the load
cases lifting and shifting by wind and by further static calculations. You will find a short version of the
wind tunnel report and a certificate for the further static calculations on our homepage.
- The design rules comply with the basic principles of structural design: SR EN 1990/NA : 2006.
- The snow loads are determined according to SR EN 1991-1-3/NA : 2017.
- The wind loads are determined according to SR EN 1991-1-4/NB : 2017.
- Service life is recognised according to ‘Eurocode EN 1991 – Action on structures, Snow loads’ and
‘Eurocode EN 1991 – Actions on structures, Wind actions’. Subject to the Building Regulations and for
security-relevant reasons the installation has to be dismantled at the end of its service life.
- Failure consequence class is considered according to ‘Eurocode EN 1990 – Basis of structural design’.

9/29/2022 K2 Base 3.1.47.0 6 | 9


Mounting systems for solar technology

STRUCTURAL ANALYSIS REPORT

GENERAL INFORMATION
Name Magura
Mounting System D-Dome 6.10 Xpress

LOCATION
Address Strada Măgura Vulturului 58,
București
Ground level 78.60 m
Roof type Flat roof
Fastening method with Ballast
Roof covering Flat
Building height 10.00 m
Parapet wall height 0.20 m
Roof pitch 0°
min. roof edge distance 0.60 m
Material Membrane
Friction coefficient 0.50

LOADS
Design method SR EN
Failure consequence class CC2 Design working life 25 years

Wind load zone 0.4 kN/m²


Terrain category I: I - Lakes, low
vegetation
velocity pressure qp,50= 1.107 kN/m²
Adjustment factor for fw = 0.921
service life
velocity pressure qp,25= 1.020 kN/m²

Snow load zone 1.5


Environment Open area
Snow load on ground sk = 1.500 kN/m²
level
Shape Coefficient for mi = 0.800
Snow
Snow load on roof si,50 = 0.960 kN/m²
Adjustment factor for fs = 0.929
service life
Snow load on roof si,25 = 0.892 kN/m²

9/29/2022 K2 Base 3.1.47.0 7 | 9


Mounting systems for solar technology

DEAD LOAD
Weight module GM = 20.5 kg Dead weight module = 11.08 kg/m²
Weight mounting system = 1.7 kg Dead weight mounting = 0.92 kg/m²
per module area system
Module area AM = 1.85 m² Total Dead Weight = 0.12 kN/m²
(excl. ballast)

LOAD COMBINATIONS

Load case combination 00: Ed = gG,sup * kFl,G * Gk + gQ * kFl,Q * Si,n


Load case combination 02: Ed = gG,sup * kFl,G * Gk + gQ * kFl,Q * Wk,Pressure
Load case combination 03: Ed = gG,sup * kFl,G * Gk + gQ * kFl,Q * (Wk,Pressure + y 0,S * Si,n)
Load case combination 04: Ed = gG,sup * kFl,G * Gk + gQ * kFl,Q * (Si,n + y 0,W * Wk,Pressure)

Load case combination 06: Ed = gG,inf * Gk + gQ * kFl,Q * Wk,Uplift

Uplift Verification: Ed = gG,stb * Gk + gQ * kFl,Q * Wk,n,Uplift


Displacement verification: Ed = gG,stb * Gk + gQ * kFl,Q * Wk,n,Displacement

USABILITY

Combination coefficient with regards to wind y 0,W 0.60


Combination coefficient with regards to Snow y 0,S 0.50

Load case combination 00: Ed = Gk


Load case combination 01: Ed = Gk + Si,n
Load case combination 02: Ed = Gk + Wk,Pressure
Load case combination 03: Ed = Gk + Wk,Pressure + y 0,S * Si,n
Load case combination 04: Ed = Gk + Si,n + y 0,W * Wk,Pressure

Load case combination 06: Ed = Gk + Wk,Uplift

THE SYSTEM HAS BEEN SUCCESSFULLY CALCULATED.

9/29/2022 K2 Base 3.1.47.0 8 | 9


Mounting systems for solar technology

BILL OF MATERIALS (ROOF 1)

Position Item no. Item description Quantity Weight

1 2003246 D-Dome 6.10 Base Set 44 146.8 kg


2 2004125 Dome 6.10 Peak 88 26.4 kg
3 2004123 Dome 6 Connector 195 Set 34 7.3 kg
4 2002870 K2 Solar Cable Manager 70 0.2 kg
5 2002558 MiniClamp MC Set 30-50 104 6.0 kg
6 2002559 MiniClamp EC Set 30-50 72 4.8 kg
7 2002300 Dome SpeedPorter 124 9.4 kg

Total 200.9 kg

9/29/2022 K2 Base 3.1.47.0 9 | 9


TOTAL BILL OF MATERIALS (ALL ROOFS)

Position Item no. Item description Quantity Weight

1 2003246 D-Dome 6.10 Base Set 44 146.8 kg


2 2004125 Dome 6.10 Peak 88 26.4 kg
3 2004123 Dome 6 Connector 195 Set 34 7.3 kg
4 2002870 K2 Solar Cable Manager 70 0.2 kg
5 2002558 MiniClamp MC Set 30-50 104 6.0 kg
6 2002559 MiniClamp EC Set 30-50 72 4.8 kg
7 2002300 Dome SpeedPorter 124 9.4 kg

Total 200.9 kg

9/29/2022 K2 Base 3.1.47.0 1 | 1