You are on page 1of 3

AN TECH GROUP

Test Report
Inv. No.
Customer Name ACCORD POWER CONVERSION PVT LTD 114/21-22 Rev. 1
Model No. APP/MAG/034/03 Qty. 5000 Page No 1/1
Date Wednesday, September 7, 2022

STATIC CHARACTERISTICS:-

Value Between
Sample No. Observation
From To Value Avg

Pin (1-3) @ 1kHz, 1 V 927µH ± 10% 885 930 916

3) Leakage Inductance :

Pin (1-3) @ 1kHz, 1V


46µH Max. 15 18 16
by shorting all other winding
4) HV Test :
3.0kV AC 60 sec Found Ok Found Ok Pass
Pri.Winding - Sec.Winding

Winding - Core 2 kV AC 60 sec Found Ok Found Ok Pass

Kavi arasu CHITRA


CHECKED BY APPROVED BY
AN TECH GROUP
Test Report
Inv. No.
Customer Name ACCORD POWER CONVERSION PVT LTD 114/21-22 Rev. 1
Model No. APP/MAG/034/03 Qty. 5000 Page No 1/2
Date Thursday, September 8, 2022
STATIC CHARACTERISTICS:-
Value Between
Sample No. Observation
From To Value Avg
Pin (1-3) @ 1kHz, 1 V 927µH ± 10% 890 925 910
3) Leakage Inductance :
Pin (1-3) @ 1kHz, 1V
46µH Max. 15 19 15.5
by shorting all other winding
4) HV Test :
3.0kV AC 60 sec Found Ok Found Ok Pass
Pri.Winding - Sec.Winding
Winding - Core 2 kV AC 60 sec Found Ok Found Ok Pass

Kavi arasu CHITRA


CHECKED BY APPROVED BY
AN TECH GROUP
Test Report
Inv. No.
Customer Name ACCORD POWER CONVERSION PVT LTD 114/21-22 Rev. 1
Model No. APP/MAG/034/03 Qty. 5100 Page No 1/3
Date Friday, September 9, 2022
STATIC CHARACTERISTICS:-
Value Between
Sample No. Observation
From To Value Avg
Pin (1-3) @ 1kHz, 1 V 927µH ± 10% 875 920 895
3) Leakage Inductance :
Pin (1-3) @ 1kHz, 1V
46µH Max. 14 18 16
by shorting all other winding
4) HV Test :
3.0kV AC 60 sec Found Ok Found Ok Pass
Pri.Winding - Sec.Winding
Winding - Core 2 kV AC 60 sec Found Ok Found Ok Pass

Kavi arasu CHITRA


CHECKED BY APPROVED BY