You are on page 1of 19

No.

: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 1 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

DCSS 5
Service Tool Reference List

Authorization Date D1 : . . . 04.Apr


. . . . . . .2005
.........................
Running on PCB : . . . . . . . . GAA
. . . . .24350
. . . . . .BD11
. . . . .and
. . . .higher
............
Software Version : . . . . . . . .GAA
. . . . .30328
. . . . . BAA
......................
Document Revision:

Date SCN Author Comment


22-Dec-1999 GAA 30328 AAA R. Löb Original document
28.Nov.2000 GAA 30328 AAC M. Barten AAC Release
05.July.2001 GAA 30328 AAD M. Barten AAD Release
17.May 2002 GAA 30328 AAE R.Löb AAE-Release
18.May 2004 GAA 30328 AAF R. Löb limited release for ADS
18.May 2004 GAA 30328 AAG R. Löb CI47-04-101
04.Apr 2005 GAA 30328 BAA R. Löb D2000-2 door

Copyright 2001 OTIS GmbH Berlin


No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of OTIS GmbH.
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 2 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

1 EVENT MENU 3

2 EVENT DESCRIPTION 4

3 SET UP PARAMETER 5

3.1 Field Parameter (key: 333) 5

3.2 Engineering Parameter (key: 334) 5


3.2.1 Profile Parameter 5
3.2.2 Profile Description 6
3.2.3 Control Parameter 7
3.2.4 Other Parameter 7

4 RELAY INTERFACE PARAMETER 8

5 INTERFACE TO RSL BOARD 9

5.1 Description of the control signals ST1, ST2 and ST3: 10

5.2 Error description of Interface Test (keys 324): 11

6 SVTOOL SHORT KEYS 11

7 ABBREVIATIONS 11

APPENDIX : 14

A) Blank Form for Installation Parameter Reports 14

B) Installation suggestion for heavy doors with 200W motor 14


No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 3 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

1 Event Menu

In order to simplify installation and maintenance the DCSS records all unusual events as a
persistent logging. The events are classified using the following convention:

Example: E39

Yxx Event Number

Event Class:

I : Information only:
Results from normal operation. For example logging of
power up events, reversal operation etc.

W: Maintenance information only:


DCSS is able to handle the situation - performance not affected.
Inspection recommended. For example: Logging full

E: Maintenance request:
Serious event, performance degradation expected. Maintenance required. For example:
3WireComFail.

The logging is available in three different representation forms as listed below.

History:
Shows the events in the order of their appearance. An included logging time stamp gives
the relation to the present time.

Actual:
Non persistent logging of up to 16 very last events, starting with the oldest event, logging
time stamp included. Additional information can be displayed on the SVTOOL by pressing
key: shift 3

EvLog:
Amount of occurrences of each event - logging time stamp included. Representation equals
to DCSS 1-4 loggings.

Del:
Deletes the logged events - clear memory for new logging period.
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 4 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

2 Event Description
Class No. Event name Event Description
I 01 Start of Log Entry indicating a new Log-Start after deleting the previous log-
ging
W 02 Logging Full Event logging memory full
- delete logging to free memory
E 03 Inverter Prot Peak output current greater than 7 A. If this event occurs 3 times
within 120 sec, the DCSS switches into locked mode.
E 04 Motor Protect Motor current was for 10 sec higher than setup limit. If this event
occurs 3 times within 120 sec, the DCSS switches to lock mode.
I 05 ObstaclDetec Door was stalled during closing, the stalled door protection has
been activated more than 10 times in series.
E 06 Encoder Err One or two tracks of the encoder are damaged. DCSS switches
into INI mode. Please check encoder counting in Monitor –
Status menu. Sometimes an error can be logged by blocking the
door run obviously encoder is ok.
Attention:
During INI/Nudg profiles and while the door is creeping before
and after a main profile, encoder errors are not detectable
W 07 Overvoltage DC-Link maximum voltage (450Vdc) exceeded – risk of damage
or lifetime reduction of DCSS package
W 08 Undervoltage Power supply voltage is less than 180Vac – risk of performance
degration
I 09 Power Up Indicates that the DCSS is booting after power down –
power up sequence
E 13 3wireComFail Indicates that the check sequence for the discrete interface failed
three times.
DCSS is set into locked mode – Maintenance required
I 15 Position Err Door runs out of the tolerated end-position range after reaching []
or ][.
I 17 Start Inst Automatic installation started
I 18 Stop Inst Automatic installation stopped by user request
I 20 InstSuccess Automatic installation successful finalized
W 21 Inst failed Automatic installation terminated with error
I 22 New Profiles Indicates that profile setup was modified
I 23 100xReversal X x 100 reversals occurred. Use this information as door mecha-
nism stress indicator
E 24 System Locked DCSS out of order, serious event occurred – maintenance
required. DCSS is de-energized and does not react on com-
mands. Root cause could be:
Motor Protect, InverterProt or 3wireComFail events.
Unlock DCSS performimg power down – power up sequence or
SVTOOL key-sequence ‘shift 5’
W 25 Stalled Door Door stalled during opening operation,
Dcss switches to Ini mode
I 26 OpenTimeout DCSS was not able to open the door within 15 sec
I 27 CloseTimeout DCSS was not able to close the door within 15 sec
I 28 3wireCom Indicates successful discrete I/O check sequence initiated by
Service Tool
I 29 Set Defaults parameters have been reset to the default values
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 5 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

3 Set Up Parameter

3.1 Field Parameter (key: 333)


This menu grants access to profile parameters which help to adapt the door performance
on the customer expectation. Enter the sub-menu 1 for profile set 1 parameters and the
sub-menu 2 for profile set 2 parameters.
name range Unit default- description
Value

Px:OpenRunTime 1500..... ms 3500 To change the open speed only this parameter must
8000 be modified. There is no impact on other parameters.
Px: StartOpnDist 1...150 mm 10 Distance from closed door to startpoint of accel.
Px: StartOpnSpeed 2...10 Hz 4 Speed at the begin of opening run
Px: OpenCrpDist 1...150 mm 20 Creep distance after main profile
Px: OpenCrpSpeed 2...15 Hz 4 Creep speed at end of opening run
Px: ClsRunTime 2500..... ms 3500 To change the close speed only this parameter must
8000 be modified. There is no impact on other parameters.
Px: StartClsDist 1...150 mm 20 Distance from opened door to startpoint of accel.
Px: StartClsSpeed 2...10 Hz 6 Speed at the begin of closing run
Px: ClsCrpDist 1...150 mm 50 Creep distance after main profile
Px: ClsCrpSpeed 2...15 Hz 3 Creep speed at end of closing run
Ix:OpnRunTime 5000 ms 6000* To change the Ini open speed
12000
Ix:ClsRunTime 5000 ms 6000* To change the Ini close speed
12000
Px: NdgClsRunTime 5000...... ms 6000* To change the close nudging speed profile
12000
Px: ClsIdleTorque 10...200 N 50 Force in [N] to hold the door closed at idle state
Px: OpnIdleTorque 10...200 N 60 Force in [N] to hold the door closed at idle state

• depends on door width setup

3.2 Engineering Parameter (key: 334)

3.2.1 Profile Parameter


This menu is for well trained adjusters only. Enter the sub-menu 1 for profile set 1 parame-
ters and the sub-menu 2 for profile set 2 parameters.
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 6 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

name range unit default description


value

Px: OpenAccelTime 15...50 % 35 acceleration time of main open profile


Px: OpenDecelTime 15...50 % 35 deceleration time of main open profile
Px: ClsAccelTime 15...50 % 35 acceleration time of main close profile
Px: ClsDecelTime 15...50 % 35 deceleration time of main close profile
Px: OpenCreep- 0...150 % 107* torque at creep speed before and after open main profile
Torque
Px: ClsCreepTorque 0...150 % 107* torque at creep speed before and after close main profile
Px: CloseTorque 0...150 % 80* torque during close main profile
Px: HaltTorque 0...150 N 60 toque to hold stopped door at position
Px: NudgingTorque 0...150 % 107* torque during close nudging main profile
Px: IniTorque 0...150 % 107* torque during ini profile run
* set by automatic learn run

3.2.2 Profile Description

Profile

2 3 4
1 5

t
Start Creep Main Profile Stop Idle
Creep CLS
Idle OPN

Velocity
Torque

note:
A detailed description of all profile types will be find in the Field Component Manual -
Guidelines
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 7 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

3.2.3 Control Parameter


name range unit default description
value

Px:P-Gain 0...300 100 Gain factor of P-Controller


Increasing of the P-Gain parameter increases the
closed loop impact. Wrong adjustment can cause
over-currents and/or bad tracking behavior.
Px:FeedUp-Gain 0...12 4* Decreasing of the FeedUp-Gain parameter results in
stronger and faster acceleration to compensate the
slippage during acceleration.
Px:FeedDown-Gain 0...12 4* Decreasing of the FeedDown-Gain parameter results in
stronger and faster deceleration.
* set by automatic learn run

3.2.4 Other Parameter


name range unit default description
value

maxMotorCurrent 800....... mA 5000 limit of max. motor current. if limit exceeded 3 times for
6000 more than 10 sec DCSS shuts down and is locked
PassProt Limit 0...100 % 4 sensitivity of stalled door protection in %
StopDistance 30...150 mm 60 reversal stop distance in mm
EndPosRange 10..100 mm 20 tolerated derivation from [] or ][ position in mm
GSM Position 50...500 mm 150 GSM active before ][ in mm
Px:Lock Distance 0...150 mm 50* Position were car & landing doors are closed, but the
lock is still open
Opn Lock Speed 0...10 Hz 5 In order to speed up the unlocking phase set parameter
higher than OpenCreepSpeed
Cls Lock Speed 0...10 Hz 8 In order to speed up the locking phase set parameter
higher than CloseCreepSpeed.
DisabRevDistOpn 0...200 mm 30 reversal is disabled if:
position > doorwidth-DisabRevDistOpn
DisabRevDistCls 20...200 mm 0 reversal is disabled if landing door is less than
DisabRevDistCls before fully closed
* set by automatic learn run
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 8 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

4 Relay Interface Parameter


This set of parameter is only available if the DCSS5 interface is programmed for a Relay
Controller(see Setup Configuration).

name range unit default description


value

DOS-Operation 0/1 0 set different operation of REL3:


0: set REL3 if door reaches programmed open position
1: set REL3 if door is opening, reset if DOL is reached
EFS-Operation 0/1 0 set different operation of input E2, if active:
0: select a second speed profile at normal run
1: EFS operation, disables all reversal devices incl.PP
REL1-Distance 1...255 mm 25 DOL signal, if position > (doorwidth - REL1distance)
then set REL1, direction = open
REL2-Distance 1...255 mm 25 DCL signal, if position < REL2distance then set REL2,
direction = close
REL3-Distance 1...255 mm 20 GH signal, if position < REL3distance then set REL3,
direction = close
REL4-Close-Dist 1...255 mm 20 SGS signal, if position < REL4-Close-Dist then set
REL4
direction = close
REL4-Open-Dist 1...255 mm 20 SGS signal, if position > (doorwidth - REL4-Open-Dist)
then set REL4, direction = open
REL5-Distance 1...255 mm 20 PMY signal, if position < REL5-Distance then set REL5
direction = close
SGS-Delay 0...1000 ms 200 set REL6 if SGSinput signal has been triggered and the
SGS delay time has timed out.
/SGS=0 SGS=1 0/1 0 inverts SGS input (P5.7 of DCSS5)
0 = low active , 1 = high active
nd
/SPEED=0 SPEED=1 0/1 1 inverts 2 speed profile input signal (P5.9 of DCSS5)
0 = low active, 1 = high active
/NDG = 0 NDG = 1 0/1 1 inverts nudging input signal (P5.8 of DCSS5)
0 = low active, 1 = high active
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 9 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

5 Interface to RSL board


Interface Box Signals DCSS 5 :
Name In Out Input at:
EDS Emergency Doorstop 6.3 to 3.2 P5.4
6.4
TCI Top of Car Inspection 6.1 to 3.3 P5.5
6.2
E6 SGS reversal signal 5.11 to 1.13 P5.7
5.12
E5 EFS Emergency Fireman 5.9 to note2)
Service 5.10 -----
DO Door open signal 5.7 to 1.12 P5.6
5.8
DC Door close signal 5.5 to note3) ___
5.6
E2 2nd speed profile / 5.3 to 1.14 P5.9
EFO(disable rev) note1) 5.4
E1 Nudging (forced closing) 5.1 to 1.15 P5.8
5.2
note 1) function depends on programming, if ENG Setup Parameter “EFS_OPERATION = 1
all reversal devices are disabled if input is activated, if parameter = 0 then a 2nd speed profile
is selected
note2) this EFS signal disables only the SGS reversal signal
note3) depends on jumper setting; the DO signal can operate as a single door open command
if jumper S1 is set to “DO”, or as a combination of DO and DC signal if S1 is set to “DO/DC”

The inputs for the SGS, 2nd PROF and NDG signal can be programmed either as 'high' active or 'low'
active input in the Setup menu ‘ENG’.
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 10 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

5.1 Description of the control signals ST1, ST2 and ST3:

Standard 3-Wire Interface:


ST1 ST2 ST3 REV Door Command Commments

0 0 0 X DED & EDS emergency door stop


0 0 1 X DED TCI, command by SVTOOL
0 1 0 X CLD close, PassProt. and Rev disabled
0 1 1 X CLD close PassProt. and Rev disabled
1 0 0 X NDG nudging, PassProt + Rev disabled
1 0 1 0 CLD&REV close, PassProt + REV enabled
1 0 1 1 CLD&REV open due to Rev device activated
1 1 0 X OPN open
1 1 1 X OPN open

Extended 3-Wire Interface with DOB and (SGS):


ST ST ST REV DOB PP SGS Door Com- Com-
1 2 3 note1 mand ments

0 0 0 X X X X DED & EDS emergency door stop


0 0 1 X X X X STOP TCI, command by SVTOOL
0 1 0 X 0 X 1 CLD & D close DOB enabled, open due SGS
X 1 X 0 open due to active DOB
0 1 1 X X X X CLD close, PP, DOB & REV disabled
1 0 0 X 0 X X NDG nudging, PP+ Rev + SGS disabled
X 1 X X open due to active DOB
1 0 1 0 0 0 0 CLD&RPD close, PP, DOB &REV enabled
1 0 0 0 open due to active REV signal
0 1 0 0 open due to active DOB signal
0 0 1 0 open due to active PP
0 0 0 1 open due to active SGS
1 1 0 0 X 0 CLD & RP close, PP & REV enabled
1 X 0 0 open due to active REV
0 X 1 0 open due to active PP
0 X 0 1 open due to active SGS
1 1 1 X X X X OPN open

note1) SGS function only available with DCSS5 SW Version GAA30328AAE or higher
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 11 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

5.2 Error description of Interface Test (keys 324):


Message Description

Interface OK Successful test – communication is ok


ST1 shortcirc, ST1+2 shortcirc, short circuit to HL2 of one or more command lines –
ST2 shortcirc, ST1+3 shortcirc, check cabling
ST3 shortcirc, ST2+3 shortcirc,
ST1-3 shortcirc
ST1 broken, ST1+2 broken, short circuit to 24Vdc or broken wire of one or more
ST2 broken, ST1+3 broken, command lines – check cabling
ST3 broken, ST2+3 broken,
ST1-3 broken
ST1 wrong connect, wrong wiring sequence, check cabling between Junc-
ST2 wrong connect tion Box and DCSS
ST3 wrong connect
no response no check sequence detected within a time interval of
400ms after request. Check LCBII/TCB especially
DOL and DOS wiring, RS board port pin addressing
and voltage levels. On check sequence request DOL
and DOS are logically High.
Unknown error DCSS was not able to interpret received commands.
Maybe the transmission of the check sequence was
disturbed. Please try check again.

6 SVTOOL Short keys


shift 3 additional information are displayed in the actual event logging menu
shift 5 unlocks the DCSS if fatal error has locked the system, same effect as power
down-up sequence
shift 7 opens the SETUP menu or opens TEST – ADAM (additional PC Window
based Tool necessary)

7 Abbreviations
2/S Telescope Door ( Two Speed Door )
C/O Central Opening Door
DCSS Door Control Subsystem
HSDS High Speed Door System
MCSS Motion Control SubSystem
OCSS Operational Control SubSystem
RAM Random Access Memory
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 12 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

DCSS Mode:

SERVICE DCSS is in Service mode (TCI active), setup and test runs are permitted. The
DCSS executes SVT door commands only.

WORKING DCSS is in normal mode (TCI & TES inactive) and the system is installed. All func-
tionality is available.

NOTSTOP Door de-energized caused by active TES

DCSS Operating Status

RDY Door position valid - executing normal profiles.


SHD Door stopped and de-energized because of a critical event or after
power up.
INI Door position not valid, executing slow Ini profiles.
RRM resume ready mode after position error (performing reversal profiles)
DED Door is de-energized.
RED Reduced operation when system is not installed - executing slow
Ini profiles only.
LCK Locked DCSS in case of serious events - system continuously
de-energized, maintenance required . Turn the DCSS power supply
off and than after 5s again on to unlock system or press <shift&5>.
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 13 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

Door Command States


CLS CLoSe Door , no reversal enabled
CLS&REV Close door but reversal device or stalled door protection is enabled
OPN OPeN Door
NDG NuDGing
DED De-energize, emergeny door stop

Door States

[] Door Fully Open


[?] Door Maybe Open (position not valid)
<> Door Opening
][ Door Fully Close
]?[ Door Maybe Closed (position not valid)
>< Door Closing

DCSS Inputs
ST1 control signal 1
ST2 control signal 2
ST3 control signal 3
REV Reversal signal, can be EDP or LRD
DOB Door Open Button (only extended 3-Wire interface)
SGS Safety Gate Shoe
TDOB Top of Car Door Open Button
TDCB Top of Car Door Close Button
SO Safe to Open
LRD Light Ray Device
EDP Electronic Door Protector

DCSS Outputs
DOL Door Open Limit Switch
DOS Door (Re-)Opening Signal (due to Passenger Protection)

General:
TCI Top of Car Inspection
EDS Emergency Door Stop
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 14 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

Appendix :

A) Blank Form for Installation Parameter Reports

B) Installation suggestion for heavy doors with 200W motor.


No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 15 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

Field-Prof1 (3-3-3-1)
name range Unit Actual description

P1:OpenRunTime 1500..... ms To change the open speed only this parameter must
8000 be modified. There is no impact on other parameters.
P1: StartOpnDist 1...150 mm Distance from closed door to startpoint of accel.
P1: StartOpnSpeed 2...10 Hz Speed at the begin of opening run
P1: OpenCrpDist 1...150 mm Creep distance after main profile
P1: OpenCrpSpeed 2...15 Hz Creep speed at end of opening run
P1: ClsRunTime 2500..... ms To change the close speed only this parameter must
8000 be modified. There is no impact on other parameters.
P1: StartClsDist 1...150 mm Distance from opened door to startpoint of accel.
P1: StartClsSpeed 2...10 Hz Speed at the begin of closing run
P1: ClsCrpDist 1...150 mm Creep distance after main profile
P1: ClsCrpSpeed 2...15 Hz Creep speed at end of closing run
I1:OpnRunTime 5000 ms To change the Ini open speed
12000
I1:ClsRunTime 5000 ms To change the Ini close speed
12000
P1: NdgClsRunTime 5000...... ms To change the close nudging speed profile
12000
P1: ClsIdleTorque 10...200 N Force to hold the door closed at idle state
P1: OpnIdleTorque 10...200 N Force to hold the door closed at idle state

Field-Prof2 (3-3-3-2)
name range Unit Actual description

P2:OpenRunTime 1500..... ms To change the open speed only this parameter must
8000 be modified. There is no impact on other parameters.
P2: StartOpnDist 1...150 mm Distance from closed door to startpoint of accel.
P2: StartOpnSpeed 2...10 Hz Speed at the begin of opening run
P2: OpenCrpDist 1...150 mm Creep distance after main profile
P2: OpenCrpSpeed 2...15 Hz Creep speed at end of opening run
P2: ClsRunTime 2500..... ms To change the close speed only this parameter must
8000 be modified. There is no impact on other parameters.
P2: StartClsDist 1...150 mm Distance from opened door to startpoint of accel.
P2: StartClsSpeed 2...10 Hz Speed at the begin of closing run
P2: ClsCrpDist 1...150 mm Creep distance after main profile
P2: ClsCrpSpeed 2...15 Hz Creep speed at end of closing run
I2:OpnRunTime 5000 ms To change the Ini open speed
12000
I2:ClsRunTime 5000 ms To change the Ini close speed
12000
P2: NdgClsRunTime 5000...... ms To change the close nudging speed profile
12000
P2: ClsIdleTorque 10...200 N Force to hold the door closed at idle state
P2: OpnIdleTorque 10...200 N Force to hold the door closed at idle state

Eng-Prof1 (3-3-4-1)
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 16 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

name range unit Actual description

P1: OpenAccelTime 15...50 % acceleration time of main open profile


P1: OpenDecelTime 15...50 % deceleration time of main open profile
P1: ClsAccelTime 15...50 % acceleration time of main close profile
P1: ClsDecelTime 15...50 % deceleration time of main close profile
P1: OpenCreepTorque 0...150 % torque at creep speed before and after open main profile
P1: ClsCreepTorque 0...150 % torque at creep speed before and after close main profile
P1: CloseTorque 0...150 % torque during close main profile
P1: HaltTorque 0...150 % toque to hold stopped door at position
P1: NudgingTorque 0...150 % torque during close nudging main profile
P1: IniTorque 0...150 % torque during ini profile run

Eng-Prof2 (3-3-4-2)
name range unit Actual description

P2: OpenAccelTime 15...50 % acceleration time of main open profile


P2: OpenDecelTime 15...50 % deceleration time of main open profile
P2: ClsAccelTime 15...50 % acceleration time of main close profile
P2: ClsDecelTime 15...50 % deceleration time of main close profile
P2: OpenCreepTorque 0...150 % torque at creep speed before and after open main profile
P2: ClsCreepTorque 0...150 % torque at creep speed before and after close main profile
P2: CloseTorque 0...150 % torque during close main profile
P2: HaltTorque 0...150 % toque to hold stopped door at position
P2: NudgingTorque 0...150 % torque during close nudging main profile
P2: IniTorque 0...150 % torque during ini profile run
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 17 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

Eng-Contrl (3-3-4-3)
name range unit Actual description

P1:P-Gain 0...300 Gain factor of P-Controller


Increasing of the P-Gain parameter increases the
closed loop impact. Wrong adjustment can cause
over-currents and/or bad tracking behavior.
P1:FeedUp-Gain 0...12 Decreasing of the FeedUp-Gain parameter results in
stronger and faster acceleration to compensate the
slippage during acceleration.
P1:FeedDown-Gain 0...12 Decreasing of the FeedDown-Gain parameter results in
stronger and faster deceleration.
P2:P-Gain 0...300 Gain factor of P-Controller
Increasing of the P-Gain parameter increases the
closed loop impact. Wrong adjustment can cause
over-currents and/or bad tracking behavior.
P2:FeedUp-Gain 0...12 Decreasing of the FeedUp-Gain parameter results in
stronger and faster acceleration to compensate the
slippage during acceleration.
P2:FeedDown-Gain 0...12 Decreasing of the FeedDown-Gain parameter results in
stronger and faster deceleration.

Eng-Other (3-3-4-4)
name range unit Actual description

maxMotorCurrent 800....... mA limit of max. motor current. if limit exceeded 3 times for
5000 more than 10 sec DCSS shuts down and is locked
PassProt Limit 0...100 % sensitivity of stalled door protection in %
StopDistance 30...150 mm reversal stop distance in mm
EndPosRange 10..100 mm tolerated derivation from [] or ][ position in mm
GSM Position 50...500 mm GSM active before ][ in mm
P1:Lock Distance 0...150 mm Position where car & landing doors are closed, but the
lock is still open
Opn Lock Speed 0...10 Hz In order to speed up the locking phase set parameter
higher than OpenCreepSpeed
Cls Lock Speed 0...10 Hz In order to speed up the locking phase set parameter
higher than CloseCreepSpeed. To reduce the overall
close time you can increase the parameter up to 8Hz if
the mechanic makes no additional noises
DisabRevDistOpn 0...200 mm reversal is disabled if:
position > doorwidth-DisabRevDistOpn
DisabRevDistCls 20...200 mm reversal is disabled if landing door is less than
DisabRevDistCls before fully closed
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 18 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

Relay (3-3-4-5)
name range unit Acutal description

DOS-Operation 0/1 set different operation of REL3:


0: set REL3 if door reaches programmed open position
1: set REL3 if door is opening, reset if DOL is reached
EFS-Operation 0/1 set different operation of input E2, if active:
0: select a second speed profile at normal run
1: EFS operation, disables all reversal devices incl.PP
REL1-Distance 1...255 mm DOL signal, if position > (doorwidth - REL1distance)
then set REL1, direction = open
REL2-Distance 1...255 mm DCL signal, if position < REL2distance then set REL2,
direction = close
REL3-Distance 1...255 mm GH signal, if position < REL3distance then set REL3,
direction = close
REL4-Close-Dist 1...255 mm SGS signal, if position < REL4-Close-Dist then set
REL4
direction = close
REL4-Open-Dist 1...255 mm SGS signal, if position > (doorwidth - REL4-Open-Dist)
then set REL4, direction = open
REL5-Distance 1...255 mm PMY signal, if position < REL5-Distance then set REL5
direction = close
SGS-Delay 0...1000 ms set REL6 if SGSinput signal has been triggered and the
SGS delay time has timed out.
/SGS=0 SGS=1 0/1 inverts SGS input (P5.7 of DCSS5)
0 = low active , 1 = high active
nd
/SPEED=0 SPEED=1 0/1 inverts 2 speed profile input signal (P5.9 of DCSS5)
0 = low active, 1 = high active
/NDG = 0 NDG = 1 0/1 inverts nudging input signal (P5.8 of DCSS5)
0 = low active, 1 = high active
No.: :GAA30328BAA_REF
OTIS Software Basic Data
SCN. :GAA30328BAA

Engineering Center Page : 19 / 19


Service Tool User´s Guide
Berlin DCSS 5 Date: 2005-04-04
Service Tool Reference List

Installation suggestions for heavy doors (200W motor)

• Max. Close Torque according to EN81


Especially for heavy doors with a 200W motor it is important to check the max
Close torque, which is defined in the EN81 as a static force of 150Newton a
door panel is pressing. To measure that close force you must block the door
with disabled reversal devices and Passenger Protection to avoid a re-
opening. The best way to do it is to enter a CLOSE command by the Service-
Tool under Menu Tools (key 3412). Enter the CLOSE command and bring the
running door to stop by blocking it. Now measure the static force with a New-
ton Meter (gauged spring). If the measured force is higher than 150N, than re-
duce the parameter Px:NudgingTorque (key3341).

This table should give a general installation suggestion to help adjusting heavy glass
door types driven with a 200W motor.

1) Fine-adjusting of the torques, which are learned during the installation, to re-
duce the forces at the door panel during closing and to avoid overcurrents.
With reduced forces the Passenger Protection will react much better.

Parameter learned value adjust to-… remarks


ClsTorque 90-100% 60-70% to improve PP and to avoid overcurrent
NudgingTorque 85-90% 65-70% to reduce static force <150N acc. EN81
IniTorque 100-110% 80-90% to reduce the torques during opening

2) Adjusting of the Creep Profile


If start of opening is too slow:

Parameter learned value adjust to-… remarks


OpnCrpSpeed 4 Hz 6Hz to accelerate the start opening
StartOpnDist 70-75mm 50mm to accelerate the start opening

2) To avoid Motorprotection Errror:

Parameter learned value adjust to-… remarks


maxMotorCur- 4000 mA 5000 mA increases the mot Current limit
rent